. -11No.LFE*-OMZ0013 Term Meaning P Power saving mode Number display is turned off to reduce power consumption. R Repeatability Reproducibility of the display or analogue output value, when the measured quantity is repeatedly increased and decreased. Response time The delay time until the set value reaches 63% in relation to the step input.

Pressure drop (P) Set the flow so that the initial pressure drop is 0.02 MPa or less. 2. Space to install Reserve maintenance space for installation and piping. 4. Operating environment Do not use in corrosive environment. Do not use where exposed to vibration or impact.

V Voltage dV dt = Voltage ratio Voltage rise % on zero-cross point dV t Time dt * For the product operation in the UL compliant conditions, refer to Installation/Operation in accordance with the UL standard in the next page.

accessory 6 Parallel inputPNP) 1 I/O cable1.5m Parallel inputNPN) Parallel inputPNP) E EtherCAT 3 I/O cable3m 9 EtherNet/IP 5 I/O cable5m P PROFINET Controller mounting 7 Screw mounting Single axis 8*1 DIN rail /High performance *1 The DIN rail is not included.

Move Speed Position Accel PushingF T riggerL V PushingSp Moving F Area1 Area2 In posn mm/s2 mm/s mm mm/s2 mm/s mm mm mm 0 Absolute 100 20.00 1000 1000 0 0 0 100 18.00 22.50 0.5 1 Absolute 50 10.00 1000 1000 70 60 5 100 6.0 12.0 1.5 63 Absolute 20 5.00 500 500 0 0 0 100 3.0 8.0 1.2 6.

.-11 Construction -12 List of valves,options,and Mounting Bolts-13 Electrical Wiring Specifications-14 to 18 F kit -14 P kit -15 T kit -16 L kit -17 M kit -18 Trouble shooting -19,20 -1No.VQC4000V-OMX0001 Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.

. -7No.EX-OMH0025-C Model Indication and How to Order Output block EX9-OE Output type 1 Source / PNP (negative common) 2 Sink / NPN (positive common) Power supply type T Internal power supply from SI unit (for low wattage load) P External power supply type (for high wattage load) : A Power block is required.

NPN output Number of outputs The number of points that can operate output device (solenoid valve) P PLC Abbreviation of programmable logic controller. A digital computer used for automation of electromechanical processes. The output type that uses a PNP transistor to operate output device.

AK ASS ASR ASF 15-9-11 3 Series AS Construction Component Parts No. q w e r t y u i o !0 !

D L2 L3 L4 L5 L6 L7 L8 P d h T L1 Model Model ASS10 ASS100 ASS110 2 10 5 20 9 5 20 52 14 4 17 50 XT14-82-3-1 1 8 ASS30 ASS300 ASS310 3.2 12 6 30 12 6 26 73 23 5 16.5 63 XT14-105-5-1 1 4 3 8 , ASS500 ASS500 2.3 14 7 35 13 6 38 99 27 6 30.5 90 XT14-89-2-1 1 2 3 4 , ASS600 ASS600 3.2 14 7 65 14 6 46 116 31 6 26 112 XT14-85-2-1 3 4 1 , AS Meter-in Control Type Meter-out Control Type ASP Mounting

Refer to front matters 58 and 59 for Safety Instructions and pages 687 to 691 for Pressure Switch Precautions. q w Locking nut t Wiring Warning e 1. Since the light emitting diode (LED) is used for the light assembly for 24 VDC, there are 2 terminals and polarity. One is + for red load wire and the other is for black load wire. Light will not light up if wired incorrectly. 2.

Pin Cylinder/Double Acting, Single Rod Series CJP2 6, 10, 16 Replacement Procedure is P.278 Construction CJP2B10, 16 CJP2B6 !1 !0 !2 !1 !0 !2 The numbers are the same as the "Construction" of the Best Pneumatics No.2 Series CJP2. *BLUE links will lead to purchase pages. Seal Kit List Description Material Note No. Replacement Parts: Seal Kit Kit no. Contents Bore size (mm) !0 !1 !

Function: 1 (2 Position Single), Body Style: 30 (Body Ported/Common Pilot EXH), Body Option: Body Ported Type, Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: B (Locking Slotted Style), Piping: Side, Port Size: 03 (Sub-plate Plug-in 1/8, Non Plug-in 3/8, Direct Ported P,A,B Ports 3),

Base Mounted Wiring: 10 (Non Plug-in Individual Lead Wire Entry), Stations: 4 Stations, Passage: 2 (P: Common, EA,EB: Common, Port A,B: Bottom), Port Size: 03 (3/8), Thread: T (NPTF)

: Non-locking Push Type, A,B Port Size: C4 (ø4 One-touch Fitting), Mounting Option: B (Mounting Screw, Hexagon Socket Head Cap Screw), Wiring Specification: W1 (w/M12 Connector Cable, 300mm), Port Location: V (Top Ported [1 (P), 5 (EA), 3 (EB) Port: Side Ported])

Cylinder Port: NPT, Arm Opening Angle: 30°, Arm Position: D (Both Sides), Switch Type: T (Turk PNP), R Arm Mtg Position: A (Mounting Position A), R Arm Style: A043 (120mm Offset Machined ref NAAMS ACA043M), L Arm Mtg Position: A (Mounting Position A), L Arm Style: A043 (120mm Offset Machined ref NAAMS ACA043M), Painted Arm: P (Paint)

Cylinder Port: NPT, Arm Opening Angle: 30°, Arm Position: D (Both Sides), Switch Type: T (Turk PNP), R Arm Mtg Position: C (Mounting Position C), R Arm Style: A008 (Straight Machined ref NAAMS ACA008M), L Arm Mtg Position: X [w/o Arm on Left Side (D Arm Position Type Only)], L Arm Style: XXXX [w/o Arm on Right Side (D Arm Position Type Only)], Painted Arm: P (Paint)

Cylinder Port: NPT, Arm Opening Angle: 30°, Arm Position: D (Both Sides), Switch Type: T (Turk PNP), R Arm Mtg Position: C (Mounting Position C), R Arm Style: A021 (25mm Offset Machined ref NAAMS ACA021M), L Arm Mtg Position: C (Mounting Position C), L Arm Style: A019 (25mm Offset Machined ref NAAMS ACA019M), Painted Arm: P (Paint)