SMC Corporation of America
Elite Part Number Search
Search Results "VV2Q22-12-DO-00N"

Example Warning Mounting 0.1 0.2 0.3 Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. 2. Insert the cable through the conduit and install the wires according to the terminal board layout below. Manifold expansion 0.4 0 Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids.

Do not use a cable longer than 10 m. Wire the DC (-) line (solenoid valve: black, pressure switch: blue) as close as possible to the power supply. 12. Do not use the product in an area where surge is generated.

Do not Do not use in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. The product is not designed to be explosion proof. Do not Do not use the product for flammable or highly permeable fluids. Fire, explosion, breakage or corrosion can result. Do not Do not use the product in a place where static electricity is a problem.

Applicable series (EA)5 1 (P) 3(EB) DC specifications of type D, Y, DO and YO are only available with 12 and 24 VDC.

Do not place work and do not transform the clamp face by a crowded installation etc. 11. Do not move the main body with the table fixed. 12. When mounting the product, use screws with adequate length and tighten them to the maximum torque or less.

Refer to each construction drawing on the fittings and tubing material. (2) Do not expose the product to direct sunlight for an extended period of time. (3) Do not use in a place subject to heavy vibration and/or shock. (4) Do not mount the product in locations where it is exposed to radiant heat. (5) Do not use the ordinary fittings and tubing in locations where static electricity would

Please contact SMC in case it is necessary to hold a stopped position for an extended period of time. 12) Do not disassemble the product or make any modifications, including additional ma chining.

Do not apply load or impact or resistance in addition to the transferred during return to origin. 19 - 8. Do not scratch or cause other damage to the body and table mounting surfaces. 9. Do not hit the table with the workpiece in the positioning operation and positioning range. 10.

Do not install by directly grasping the cylinder tube, as this could cause a tube to deform and malfunction. 2. Do not install it by directly grasping the piston rod with a pair of electricians pliers. Scratches on the piston rod would cause a bearing or rod seal to get damaged, malfunction, and leak air. 10 12.4 4 15 12.8 20 13.2 16

Name Material Remarks 1 Body Stainless steel 2 Spool Special stainless steel 3 Sleeve Special stainless steel 4 Plate Aluminium 5 O-ring H-NBR 6 Retaining ring Carbon steel 7 Retaining ring Carbon steel 8 Radial bearing MQR2 to 12-M5 Components / (MQR2 to 12 M5, 2 to 12 circuits) No.

Do not Do not use in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. The product is not designed to be explosion proof. Do not Do not use the product in a place where static electricity is a problem. Otherwise failure or malfunction of the system can result.


Do not use coils for DC in valves whose rated voltage is AC, and vice versa.
Note) The “VO317” part number indicates that the valve is for use in a manifold.
The series part number is “VT317.” The VT317 (VO317) series catalog can be found here.

(After discharge, do not forget to return the drain cock to its original position by tightening it clockwise.)
With auto drain: Normally, drain discharge is performed automatically when drain accumulates, so no action is required.
However, drain can be discharged by manual operation if needed.

Operating Environment Do not use in an atmosphere having corrosive gases, or where there is direct contact with this. Do not use in dusty locations or where water or oil, etc., splash on the equipment. Do not use in a place subject to heavy vibration and/or shock. Speed Adjustment To make a speed adjustment, gradually adjust starting from the low speed end.

A Note 1) 4 6 4 6 8 4 6 8 10 6 8 10 12 10 12 AS121FP-M5-04 AS121FP-M5-06 AS221FP-01-04 AS221FP-01-06 AS221FP-01-08 AS221FP-02-04 AS221FP-02-06 AS221FP-02-08 AS221FP-02-10 AS321FP-03-06 AS321FP-03-08 AS321FP-03-10 AS321FP-03-12 AS421FP-04-10 AS421FP-04-12 28 7 7 18.4 23.2 8 10.4 22.2 25 25.5 28.3 9.6 M5 x 0.8 12.2 29 8 8 19.4 24.2 12.8 32.4 17 17 18.4 25.3 10.4 27.4 32.4 31.4 36.4 14.2 12

Do not use in direct sunlight. Operating Environment Do not use in direct sunlight. It may cause malfunction or damage. 12. Use this product within the specified ambient temperature 1. Do not use in an atmosphere containing an inflammable range. This may cause malfunction. gas or explosive gas. Use in such an atmosphere is likely to cause a fire or explosion.

Do not disassemble, modify, or repair the controller and its peripheral devices. 4. Do not put anything conductive or flammable inside of the controller. It may cause a fire. 5. Do not conduct an insulation resistance test or withstand voltage test on this product. 6. Ensure sufficient space for maintenance activities.

Do not Do not use in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. The product is not designed to be explosion proof. Do not Do not use the product for flammable or highly permeable fluids. Fire, explosion, breakage or corrosion can result. Do not Do not use the product in a place where static electricity is a problem.

Do not cut the tubing with pliers, nippers, scissors, etc., otherwise the tubing will be deformed and problems may result. (3) When mounting the tube, resin plug or metal rod, do not press the release button. Do not press the release button unnecessarily before mounting tubing, resin plugs and metal rods.

Do not ground it with devices generating strong electromagnetic noise. 3. Do not pull sensor cable strongly. Such action may cause failure. 4. Check wiring Incorrect wiring may cause damage or malfunction of the products. Make sure the wiring is correct before operation. 4. Power supply line Do not mount any switch or relay to power supply line (12 VDC to 24 VDC).