VFN 48 V DC None Z Precautions Plug a connector in or out vertically, never at an angle. How to Calculate the Flow Rate S 6 V For obtaining the flow rate, refer to page 3-1-10.
Type: VK33V (VK33W) No.1 No.1 None Z Varistor Neon bulb Diode Neon bulb Coil Coil In contrast to the standard product, this vacuum specification valve has less air leakage at low pressures, a feature that should be taken into consideration when using this valve for vacuum applications.
Applicable cable O.D. 3.5 to 7 (Reference) 0.5 mm2 2 core and 3 core wires equivalent to JIS C 3306 24 V No.2() Black() 48 V No.1 Diode DC None Z Coil LED No.2 No.1 S Coil Coil Varistor Varistor 6 V No.2 12 V No.1 DC None Z Coil No.2 Precautions on connection for 24 VDC or more Grommet type should be connected as following; Red lead wire for (+) side, Black lead wire for () side respectively
Adsorption Confirmation Switch Series ZSP1 ZSE ISE PSE For General Pneumatics Z I SE3 PS Z I SE1 2 ZSP ISA2 IS ZSM PF2 IF Data Can be integrated with ZX ejector system.
Centralized wiring of ejector (ZYX3000: Individual pressure switch not included) ZMA ZQ ZH ZU ZL ZY ZF ZP SP ZCUK AMJ Series ZYX3000 (Solenoid valve: SX3000) AMV AEP Series ZYY3000 (Solenoid valve: SY3000) HEP Related Equipment 1081 Ejector Valve Unit Series ZYY/ZYX How to Order Ejector Valves for ZYY3000 Lead wire/ Voltage suppressor specifications Connector box type LOU L Z 5 LOU 10 Y3
Incremental type 14.5 mT 10.8 to 13.2 VDC (Ripple less than 1%) 40 mA 0.1 mm/pulse 0.2 mm Note) (at 20C) NPN open collector (35 VDC, 80 mA) A/B phase difference output 500 VDC, 50 M or more (between case and 12E) 33.3 Hz, 2 hours at X, Y and 4 hours at Z JIS D 1601 as standard 30 G, 3 times at X, Y, Z IP50 (IEC standard) Maximum transmission distance Position detection method Magnetic field
Lead wire length symbols: 0.5 m Nil (Example) R73C 3 m L (Example) R73CL 5 m Z (Example) R73CZ None N (Example) R73CN Order example: MSUA20 single vane type (connection port side location selected) 1. Standard type (Without auto switches), Rotation 90, side port location MSUA20-90S 2. With switch unit (Without auto switches), Rotation 180, side port location MDSUA20-180S 3.
L D-A73 (Example) RS H A Lead wire length RZQ 5 m None Nil L 0.5 m 3 m Z N MI W S Applicable for the connector type (D-C) only.
Incremental type 14.5 mT 10.8 to 13.2 VDC (Ripple less than 1%) 40 mA 0.1 mm/pulse 0.2 mm Note) (at 20C) NPN open collector (35 VDC, 80 mA) A/B phase difference output 500 VDC, 50 M or more (between case and 12E) 33.3 Hz, 2 hours at X, Y and 4 hours at Z JIS D 1601 as standard 30 G, 3 times at X, Y, Z IP50 (IEC standard) Maximum transmission distance Position detection method Magnetic field
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model Basic type With cap With cap Basic type dimensions h Hexagon nut F MM H 2.4 2.4 2.7 2.7 a 5 6 6 7 E1 2.8 2.8 3 3 D M8 x 1.0 M8 x 1.0 M10 x 1.0 M10 x 1.0 E2 L LL S E3 LL Z B C RHC RB0805 RB0806 RB1006 RB1007 RBC0805 RBC0806 RBC1006 RBC1007 1.4 1.4
Lead wire length symbols: 0.5 m Nil (Example) A73C 3 m L (Example) A73CL 5 m Z (Example) A73CZ None N (Example) A73CN D-P5DWL is available in sizes 40 to 63. In addition to the models in the above table, there are some other auto switches that are applicable.
L D-A73 (Example) CS1 Lead wire length C76 5 m None Nil L 0.5 m 3 m Z N C85 Applicable for the connector type (D-C) only.
clevis B L F G C D Rod Bore size Single rod Double rod Nil 32 40 50 63 80 100 32 mm 40 mm 50 mm 63 mm 80 mm 100 mm W Applicable Auto Switch/Tie-rod Mounting Type Load voltage Auto switch model Electrical entry direction Lead wire length (m) Note) Electrical entry Indicator light Wiring (Output) Applicable load Mounting bracket Type Special function AC Vertical Lateral 0.5 (Nil) 3 (L) 5 (Z)
Lead wire length (m) Load voltage Direct mounting Rail mounting Indicator light Applicable load Special function Type Electrical entry Wiring (output) 12 to 50 32 to 50 None (N) 0.5 (Nil) 3 (L) 5 (Z) AC DC In-line In-line Perpendicular Perpendicular 3-wire (NPN equiv.)
AC DC Auto switch model Lead wire length (m) Load voltage Indicator light Pre-wire connector Special function Type Electrical entry Wiring (Output) Applicable load 0.5 (Nil) 3 (L) 5 (Z) Perpendicular In-line 3-wire IC circuit Reed switch Solid state switch Z76 5 V Yes Yes Grommet (NPN equivalent) Relay, PLC 24 V 12 V Solid state switches marked with are produced upon receipt of order.
L D-A73 (Example) CLQ Lead wire length MLGP 5 m None Nil L 0.5 m 3 m Z N RLQ Applicable for the connector type (D-C) only.
Auto switch model Electrical entry direction Lead wire length (mm) Load voltage Type Electrical entry Indicator light Wiring (Output) Special function Applicable load 5 (Z) AC DC 0.5 (Nil) 3 (L) Perpendicular In-line Z76 5 V IC circuit 3-wire Yes Reed switch Z73 12 V 100 V Grommet Relay, PLC 24 V 2-wire Z80 5 V, 12 V 100 V or less No IC circuit Y59A Y69A 3-wire (NPN) IC circuit 5 V, 12
Series CM2-Z stainless steel cylinders with temperature options offer the same compact, lightweight and high performance as the standard CM2-Z. The piston seal and rod seal design provides excellent life. The CM2-Z series delivers extra flexibility including the option of male and female rods.
The CM2-Z series offers a variety of mounting options.