Terminal 1/2, Non Plug-in Standard 1/2)
1/2, Non Plug-in Standard 1/2), Thread: F (G)
Function: 2 (2 Position Double), Body Option: 0 (Base Mounted Plug-in), Direct Manual Override: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: F (Plug-in Conduit w/Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: B (Bottom Ported), Port Size: 04 (Sub-plate Plug-in Terminal 1/2, Non Plug-in Standard 1/2), Thread:
1/2, Non Plug-in Standard 1/2), Thread: T (NPTF)
Plug-in Terminal 1/2, Non Plug-in Standard 1/2), Thread: T (NPTF)
Function: 2 (2 Position Double), Body Option: 0 (Base Mounted Plug-in), Direct Manual Override: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: F (Plug-in Conduit w/Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side Ported (Or None in Case of w/o Subplate), Port Size: 04 (Sub-plate Plug-in Terminal 1/2, Non Plug-in
/2, Non Plug-in Standard 1/2), Thread: T (NPTF)
Valve: None; Stop Valve: None, Supply/Return Port Size: 1/2, Return Unit Flow Switch Output Specifications: Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: Integrated Display: L/min; Accumulated Flow: L; Temp.: °F
Valve; w/Stop Valve, Supply/Return Port Size: 1/2, Return Unit Flow Switch Output Specifications: Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: Integrated Display: L/min; Accumulated Flow: L; Temp.: °F
Series: Double Rod, Mounting: MF1, Front Flange, Bore Size: 2 1/2", Stroke: 5 1/2", Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.
Series: Double Rod, Mounting: MT4, Center trunnion, Bore Size: 2 1/2", Stroke: 2", Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.
Valve; w/Stop Valve, Supply/Return Port Size: 1/2, Return Unit Flow Switch Output Specifications: Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: Integrated Display: L/min; Accumulated Flow: L; Temp.: °F
Valve; w/Stop Valve, Supply/Return Port Size: 1/2, Return Unit Flow Switch Output Specifications: Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes, Lead Wire: w/M12 -M8 Conversion Lead Wire, 0.1 m, Return Unit Flow Switch Unit Specifications: Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F
Series: Double Rod, Mounting: MX0, Basic, Bore Size: 2 1/2", Stroke: 5 1/2", Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: F (G), Port Size: 04 (1/2), Output Specification/Temperature Sensor: LT (Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C), Bracket: None