SMC Corporation of America
Elite Part Number Search
Search Results "PFM525-C8-2-A-T"

Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to direct sunlight. 2.

Use hexagon socket head cap screws (JISB1176, strength class 10.9 or higher) for cylinder mounting. 2. Since a lateral load (eccentric load) cannot be applied to the piston rod, build the mounting jig in such a way that a lateral load will not be applied to the piston rod. 3.

Also note that a current greater than that specified will damage a light emitting diode and it will no longer operate. Applicable models: D-Z73 2) However, in the case of a 2 color indicator type auto switch (DA59W), note that the switch will be in a normally ON condition if connections are reversed.

Applicable for pressure detection with a wide range of fluids, by using a stainless steel diaphragm. 16-2-25 2 Pressure detection for a wide range of fluids.

when the solenoid valve is turned ON and closes when it is turned OFF. 10 XL-OMV0016 5-2.Dimensions C (KF flange) (K flange) Fd Fn C J Port 1(P) S K L M N B T Port 3(R) A G A Unit: mm Model A B C Fn Fd G J XLAV-16-2 40 108 38 30 17 41 XLAV-25-2 50 121 48 40 26 46 XLAV-40-2 65 171 66 55 41 54.5 XLAV-50-2 70 185 79 75 52 61 XLAV-63-2 88 212 100 87 95 70 80.5 XLAV-80-2 90 257 117 114 110 83

As a guide, it can be tightened about 90 past the position at which tightening can be felt. Auto switch model Size (mm) 20 25 32 40 D-M9/M9V Note) 2 2 2 2 D-M9W/M9WV D-M9AL/M9AVL D-A9/A9V 3 3 3.5 3 6.5 6 6 5.5 Since this is a guideline including hysteresis, not meant to be guaranteed.

MY-SA 2 x G F E 2 x H A B C D Side support B MY-SB 2 x J A B C D A 61 70 87 B 75 84 105 C D E F G H J Part no.

7 Working principle Port 1(P) is normally pressurized, and the valve opens when the solenoid valve is turned ON and closes when it is turned OFF. 10 XL-OMV0019 5-2.Dimensions C (KF flange) (K flange) Fd Fn C J Port 1(P) S K L M N B T Port 3(R) A G A Unit: mm Model A B C Fn Fd G J XLFV-16-2 40 108 38 30 17 41 XLFV-25-2 50 121 48 40 26 46 XLFV-40-2 65 171 66 55 41 54.5 XLFV-50-2 70 185 79 75

MXW A 16 12 X11 Change of adjuster assembly Option (-X11) Standard Changing the stroke adjustment range from 5 mm to 15 mm for one side A Replace W/o shock absorber 2 Applicable bore size (mm) Nil X11 Replace A B With shock absorber Adjustment range 4 5 mm 15 mm Standard Option MXW8 MXW12 MXW16 MXW20 MXW25 8 12 16 20 25 Changing to the one with shock absorber Add B 2 A B Replace Add Changing

High Suction Vacuum Work 1 Work 2 Work n Max.A ON point OFF point Min.B Not adsorption Work 1 Work 2 Work n Atmosphere A B 4 A B 4 = A ON point Max.A: Maximum pressure value when work piece is vacuumed. Min.B : Maximum pressure value when work piece is not vacuumed.

GR-L-010 (10 g) D-X Individual -X 1225 Series RZQ Dimensions Basic style (Double end tapped): RZQA 3 x P (Port size: Rc, NPT, G) FA Q FB H effective thread depth C G I D E M K Z a a A + Full stroke L B + Full stroke M K J E W T RA 4 x O1 effective thread depth RB 4 x O1 Section a-a Basic style (Through-hole): RZQB 32, 40 Washer 2 x RR 2 x RH Flat washer: 2 positions (Included) b 2 x N 2 x

D-Y7WV D-Y7BAL D-A3 D-A44 D-G39 D-K39 D-A5 D-A6 D-A59W D-F5NTL D-F5LF D-P5DWL Bore size (mm) A A A A B A A A A B B B B B B B 32 12 11 7 4.5 0 0.5 3.5 4 0.5 9.5 8.5 4.5 2 1 1.5 0 40 12 11 7 4.5 0 0.5 3.5 4 0.5 9.5 8.5 4.5 2 1 1.5 0 50 12.5 11.5 7.5 5 0 1 4 4.5 1 10 9 5 2.5 1.5 2 0 63 12.5 11.5 7.5 5 0 1 4 4.5 1 10 9 5 2.5 1.5 2 0 80 15.5 14.5 10.5 8 2.5 4 7 7.5 4 14 13 9 6.5 5.5 6 2.5 100

0 @2 w u !1 !2 !7 !5 @0 o y !9 !8 !4 r t e !6 Component Parts MHZ Note Material Material No. Description No.

CAT.ES100-49 A Low Differential Pressure Sensor Rated differential pressure range: 0 to 2 kPa 0 to 2 0 to 2 kPa kPa 0 to 2 0 to 2 kPa kPa Accuracy: 1% F.S. 1% % F.S. F.S. 1% % F.S. F.S.

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS1000 How to Order 01 VFS1 1 20 1 G Symbol Option 2 position single F: With foot bracket Thread type 1 Nil N Rc NPT NPTF G T Port size 01 F Rc 1 8 2 position double SJ Option 2 Mountable only for VFS1120.

M K E Z a a L B + Full stroke M K A + Full stroke J E 4-O1 effective thread depth RB RA W 4-O1 T Section a-a Standard type (Through hole type)/RZQB 2-RR 50, 63 Flat washer (Included) 4-HR 2-RR Flat washer (Included) b 2-N 4-O 4-N b Section b-b (mm) Bore size (mm) A B C D E FA FB G H I J K L M N O1 O P Q RA RB RR RH T W Z 100.5 82.5 14 22.4 45 33 12.5 9 M8 x 1.25 60 4.5 17 18 34 5.5 M6 x 1.0

When ordering a valve with a lead wire of 600 mm or longer, be sure to indicate the model number of the valve without connector and connector assembly. A-C ON Orange P A P A Orange OFF A R B-C ON (Reset) A R Green 4-12-4 5 Series VQ100 Precautions Be sure to read before handling. For Safety Instructions and Solenoid Valve Precautions, refer to page 4-18-2.

V100 SY (L5) Plug assembly 1 2 3 2-4.5 mounting hole (L4) SYJ VVQ100-12A(L3) 88 (8.5) L2 VK 48.7 L1 VZ VT (45) (35) 33 25 (5.5) 23.5 VP 12.3 VG R11 (Min. bending inner radius) Manual override 21.5 (29.3) VP 104 S070 VQ VKF Stations12345n D side U side VQZ 2-M5 x 0.8 (E port) VZ 2-M5 x 0.8 (P port) VS 43.5 A A VFN 20 (8.5) 1.5 5 (7.5) n-M5 x 0.8 (A port) 5 15 P = 10 38 n: Stations (Maximum

V100 SY (L5) Plug assembly 1 2 3 2-4.5 mounting hole (L4) SYJ VVQ100-12A(L3) 88 (8.5) L2 VK 48.7 L1 VZ VT (45) (35) 33 25 (5.5) 23.5 VP 12.3 VG R11 (Min. bending inner radius) Manual override 21.5 (29.3) VP 104 S070 VQ VKF Stations12345n D side U side VQZ 2-M5 x 0.8 (E port) VZ 2-M5 x 0.8 (P port) VS 43.5 A A VFN 20 (8.5) 1.5 5 (7.5) n-M5 x 0.8 (A port) 5 15 P = 10 38 n: Stations (Maximum