Porting Port size Weight lb (g) Small Size Pressure Gauge 15mm Reverse flow function available on the standard model IN OUT Total weight (n: stations) Regulator (Except manifold) (80 X n) + 23 Common IN 1 8 1 8 .13 (57) NARM1000 (79 X n) + 25 Individual IN 1 8 1 8 Common IN (188 X n) + 43 1 4 1 8 .3 (136) NARM2000 Individual IN (187 X n) + 45 1 8 1 8 Space Saving How to Order Option NARM 1000
M12 Connector Cable (4 Pins) Made by OMRON Part number Cable length [mm] ZS-37-L 300 ZS-37-M 500 ZS-37-N 1000 ZS-37-P 2000 ZS-37-C 5000 Part number Cable length [mm] Changing the entry direction After separating the terminal block and housing, the cord entry can be changed by attaching the housing in the opposite direction 180.
Order Connector Assembly for L/M Plug Connector Construction Series SX Positive common specifications 2 position single JIS Symbol 2 position single For single solenoid: SX100 40 4S For double solenoid, 3 position: SX100 40 4D Negative common specifications For single solenoid: SX100 41 4S For double solenoid, 3 position: SX100 41 4D Lead wire length Nil 300 mm 6 600 mm 10 15 20 25 30 50 1000
With light/surge voltage suppressor (Non-polar type) : SY100-30-A U Without lead wire (with connector and 2 of sockets only) Lead wire length Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Rated voltage 5 6 V S R 1 2 Electrical entry 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] G H L LN LO M MN
FLOW CAPACITY . 10-32 port 1/8" NPT port .6 CFM (16 LPM) @ 30 PSI (207 kPa) set .7 CFM (19 LPM) @ 30 PSI (207 kPa) set Operating characteristics are influenced by flow and outlet restriction Part Number Description RV-5200-10RV-5200-30RV-5200-60RV-5200-1000-10 PSI, 10-32 ports 0-30 PSI, 10-32 ports 0-60 PSI, 10-32 ports 0-100 PSI, 10-32 ports XX XX XX XX 0-10 PSI, 1/8" NPT ports 0-30 PSI,
Electrical entry Grommet Power supply voltage 12 to 24 VDC Current consumption 40 mA or less Output specification NPN open collector 2 outputs PNP open collector 2 outputs Load voltage 28 VDC or less Impact resistance 980 m/s2 Insulation resistance 50 M or more (500 VDC measured via megohmmeter) between lead wire and case Withstand voltage 1000 VAC for 1 minute (between lead wire and case
14 Flow rate (l/min (ANR)) Inlet pressure : 0.5 MPa Inlet pressure : 0.5 MPa Flow rate (l/min (ANR)) Effective area (mm2) Effective area (mm2) 20 10 11,12,13 12 10,11 08,09 1000 10 15 8 500 10 6 500 4 5 2 0 0 5 10 0 5 10 0 Number of needle rotations Number of needle rotations 548 Series ASP Speed Controller with Pilot Check Valve with One-touch Fitting Dimensions Applicable tubing O.D. d
Display the error code on LCD. 3 1/2 digits (5 mm-size numerals) Overcurrent, Overpressure, Data error Pressure during 0 clear 0 to 60C (No dewing) 1000 Vp-p, Pulse width 1 s, Rise time 1 ns 1000 VAC in 50/60 Hz for 1 minute between live parts and case 2 M or more (at 500 VDC by megameter) betweeen live parts and case 10 to 500 Hz Pulse width 1.5 mm or acceleration 98 m/s2 (at the smaller
Co., Ltd. 65 or less 1.5 m 3 m 5 m AXT100-DS25-015 Cable 25 cores x 24AWG AXT100-DS25-030 Voltage limit VAC, 1 min. 1000 AXT100-DS25-050 For other commercial connectors, use a 25 pins type with female connector conforming to MIL-C24308. Insulation resistance Mkm, 20C 5 or less Note) The minimum bending radius for D-sub connector cables is 20 mm.
BMB4-050 BMB3T-050 BT-06 BMB4-063 BMB3T-080 6-12-2 Series C95 Specifications Bore size (mm) 32 40 63 100 50 80 Action Double acting Fluid Air 1.5 MPa Proof pressure 1.0 MPa Max. operating pressure 0.05 MPa Min. operating pressure Without auto switch: 10 to 70C (No freezing) With auto switch: 10 to 60C (No freezing) Ambient and fluid temperature Not required (Non-lube) Lubrication 50 to 1000
1500 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 25 3000 32 3000 40 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 50 5000 63 Note 1) Long stroke specification (XB11) applies to the strokes exceeding 2000 mm.
(mm) 12 REA 25 300 Cylinder stroke (mm) Type Port type Symbol Nil TN TF Rc NPT G Model Bore size (mm) Maximum manufacturable stroke (mm) Port size Model Standard stroke (mm) Lubrication Rc1/8 NPT1/8 G1/8 Rc1/4 NPT1/4 G1/4 12-REA25 12-REA32 25 32 40 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 12-REA40 12-REA50 50 1300 Non-lube 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000
Thermo-chiller/ Rack Mount Type HRR Series How to Order Option U Air-cooled Refrigeration HRR A 20 012 (UL Standards) Cooling capacity Option 012 1000/1200 W (50/60 Hz) 018 1600/1800 W (50/60 Hz) 024 2000/2400 W (50/60 Hz) 030 2500/3000 W (50/60 Hz) Nil None DM With electric conductivity control function, Applicable to DI water piping M Applicable to DI water piping T High-pressure pump mounted
Model Piping Port size Weight (g) IN side OUT side Total weight (n: stations) Regulator (Except manifold) IR Small size pressure gauge 15 Backflow function available on the standard model Space-saving (80 x n) + 23 (79 x n) + 25 (188 x n) + 43 (187 x n) + 45 Common IN Individual IN Common IN Individual IN 1 8 1 8 ARM1000 57 1 8 1 8 IRV 1 4 1 8 ARM2000 136 1 8 1 8 VEX How to Order SRH ARM 1000
14 Flow rate (l/min (ANR)) 20 Flow rate (l/min (ANR)) 10,11 12 Effective area (mm2) Effective area (mm2) 12 10,11,12 08,09 1000 10 15 8 500 06,07 10 6 500 4 5 2 0 0 5 10 0 5 10 0 Number of needle rotations Number of needle rotations 15-9-15
Flow rate (l/min (ANR)) 14 Inlet pressure : 0.5 MPa Inlet pressure : 0.5 MPa Flow rate (l/min (ANR)) Effective area (mm2) Effective area (mm2) 20 10 11,12,13 12 1000 10,11 08,09 10 15 8 500 10 6 500 4 5 2 0 0 5 10 0 5 10 0 Number of needle rotations Number of needle rotations 548
psig/bar unit MPa unit Surface finish No gauge port No code Seat material Surface finish Ra 10 in. (0.25 m) Standard 25 in. (0.62 m) Code No pressure gauge (Connections: 1/4 inch face seal male) 0 Code Material PCTFE (Standard) Vespel 3) PTFE 4) 5) No code Q No code VS TF -30 in.Hg to 30 psig -30 in.Hg to 60 psig -30 in.Hg to 100 psig -30 in.Hg to 160 psig 0 to 200 psig 0 to 400 psig 0 to 1000
mm, to 1200 mm 20 to 63 Stroke length tolerance to 1000 mm, to 1500 mm 80, 100 Basic type, Axial foot type, Front flange type, Rear flange type, Integral clevis type Mounting JIS symbol Double acting/Single rod Standard Strokes (mm) Note 1) Standard stroke Long stroke Bore size 25, 50, 75, 100, 125, 150, 200 201 to 350 20 Minimum stroke for mounting auto switches 301 to 400 25 301 to 450
mm, to 1200 mm 40 to 63 to 1000 mm, to 1500 mm 80, 100 2
XC14 Change of rod end shape Minimum operating pressure (MPa) Head: 0.15 Rod: 0.2 Change of trunnion bracket mounting position DWithout auto switch: 10 to 80C With auto switch: 10 to 60C Ambient and fluid temperature 8 to 300 mm/s Piston speed Cushion seal type Cushion Rod Sizes +0.8 0 +1.25 0 +1.0 0 +1.4 0 +1.8 0 Stroke length tolerance to 100 st , 101 to 250 st , 251 to 630 st , 631 to 1000