Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.08~0.97, Cushion: With
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Auto Switches: M9P, Lead Wire Length(m): 5, The number
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 25, Cylinder Operation Method: [Single Action Retraction] Single Acting, Spring Extend, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): null~1.0, Port thread type: NPT,
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05 to 1, Specification: Built-in magnet,
How Grip: Pinch, Parallel Type / Open, Parallel Type, Number of Fingers: 2 Pcs., Open Dimension L1(mm): 33.3, Closed Dimension L2(mm): 19.3, Type: [Main Body] Body, Operation Method: Double Acting, Main Body Shape: Square Shape, Gripping Force (Closed Side at 0.5 Mpa)(N): 65, Gripping Force (Open Side at 0.5 Mpa)(N): 104, Environment, Applications: Standard, Additional Function: With Linear
How Grip: Pinch, Chuck Type / Open, Chuck Type, Number of Fingers: 2 Pcs., Open Dimension L1(mm): 16, Closed Dimension L2(mm): -, Type: [Main Body] Body, Operation Method: Double Acting, Main Body Shape: Square Shape (Flat Shape), Gripping Force (Closed Side at 0.5 Mpa)(N): 19, Gripping Force (Open Side at 0.5 Mpa)(N): 19, Environment, Applications: Standard, Additional Function: With Linear
How Grip: Pinch, Chuck Type / Open, Chuck Type, Number of Fingers: 2 Pcs., Open Dimension L1(mm): 24, Closed Dimension L2(mm): -, Type: [Main Body] Body, Operation Method: Double Acting, Main Body Shape: Square Shape (Flat Shape), Gripping Force (Closed Side at 0.5 Mpa)(N): 48, Gripping Force (Open Side at 0.5 Mpa)(N): 48, Environment, Applications: Standard, Additional Function: With Linear
How Grip: Pinch, Parallel Type / Open, Parallel Type, Number of Fingers: 2 Pcs., Open Dimension L1(mm): 15.2, Closed Dimension L2(mm): 11.2, Type: [Main Body] Body, Operation Method: Double Acting, Main Body Shape: Cylindrical Shape, Gripping Force (Closed Side at 0.5 Mpa)(N): 10, Gripping Force (Open Side at 0.5 Mpa)(N): 18, Environment, Applications: Standard, Additional Function: Not Provided
How Grip: Pinch, Parallel Type / Open, Parallel Type, Number of Fingers: 2 Pcs., Open Dimension L1(mm): 15.2, Closed Dimension L2(mm): 11.2, Type: [Main Body] Body, Operation Method: Double Acting, Main Body Shape: Cylindrical Shape, Gripping Force (Closed Side at 0.5 Mpa)(N): 10, Gripping Force (Open Side at 0.5 Mpa)(N): 18, Environment, Applications: Standard, Additional Function: Not Provided
How Grip: Pinch, Parallel Type / Open, Parallel Type, Number of Fingers: 2 Pcs., Open Dimension L1(mm): 20.9, Closed Dimension L2(mm): 14.9, Type: [Main Body] Body, Operation Method: Double Acting, Main Body Shape: Cylindrical Shape, Gripping Force (Closed Side at 0.5 Mpa)(N): 30, Gripping Force (Open Side at 0.5 Mpa)(N): 40, Environment, Applications: Standard, Additional Function: Not Provided
How Grip: Pinch, Parallel Type / Open, Parallel Type, Number of Fingers: 2 Pcs., Open Dimension L1(mm): 20.9, Closed Dimension L2(mm): 14.9, Type: [Main Body] Body, Operation Method: Double Acting, Main Body Shape: Cylindrical Shape, Gripping Force (Closed Side at 0.5 Mpa)(N): 30, Gripping Force (Open Side at 0.5 Mpa)(N): 40, Environment, Applications: Standard, Additional Function: Not Provided
How Grip: Pinch, Parallel Type / Open, Parallel Type, Number of Fingers: 2 Pcs., Open Dimension L1(mm): 20.9, Closed Dimension L2(mm): 14.9, Type: [Main Body] Body, Operation Method: Double Acting, Main Body Shape: Cylindrical Shape, Gripping Force (Closed Side at 0.5 Mpa)(N): 30, Gripping Force (Open Side at 0.5 Mpa)(N): 40, Environment, Applications: Standard, Additional Function: Not Provided
How Grip: Pinch, Parallel Type / Open, Parallel Type, Number of Fingers: 2 Pcs., Open Dimension L1(mm): 26.3, Closed Dimension L2(mm): 16.3, Type: [Main Body] Body, Operation Method: Double Acting, Main Body Shape: Cylindrical Shape, Gripping Force (Closed Side at 0.5 Mpa)(N): 41, Gripping Force (Open Side at 0.5 Mpa)(N): 66, Environment, Applications: Standard, Additional Function: Not Provided
How Grip: Pinch, Parallel Type / Open, Parallel Type, Number of Fingers: 2 Pcs., Open Dimension L1(mm): 26.3, Closed Dimension L2(mm): 16.3, Type: [Main Body] Body, Operation Method: Double Acting, Main Body Shape: Cylindrical Shape, Gripping Force (Closed Side at 0.5 Mpa)(N): 41, Gripping Force (Open Side at 0.5 Mpa)(N): 66, Environment, Applications: Standard, Additional Function: Not Provided
How Grip: Pinch, Parallel Type / Open, Parallel Type, Number of Fingers: 2 Pcs., Open Dimension L1(mm): 33.3, Closed Dimension L2(mm): 19.3, Type: [Main Body] Body, Operation Method: Double Acting, Main Body Shape: Cylindrical Shape, Gripping Force (Closed Side at 0.5 Mpa)(N): 68, Gripping Force (Open Side at 0.5 Mpa)(N): 100, Environment, Applications: Standard, Additional Function: Not
How Grip: Pinch, Parallel Type / Open, Parallel Type, Number of Fingers: 2 Pcs., Open Dimension L1(mm): 33.3, Closed Dimension L2(mm): 19.3, Type: [Main Body] Body, Operation Method: Double Acting, Main Body Shape: Cylindrical Shape, Gripping Force (Closed Side at 0.5 Mpa)(N): 68, Gripping Force (Open Side at 0.5 Mpa)(N): 100, Environment, Applications: Standard, Additional Function: Not
How Grip: Pinch, Parallel Type / Open, Parallel Type, Number of Fingers: 2 Pcs., Open Dimension L1(mm): 33.3, Closed Dimension L2(mm): 19.3, Type: [Main Body] Body, Operation Method: Double Acting, Main Body Shape: Cylindrical Shape, Gripping Force (Closed Side at 0.5 Mpa)(N): 68, Gripping Force (Open Side at 0.5 Mpa)(N): 100, Environment, Applications: Standard, Additional Function: Not
Oscillation Angle A: 100°, Torque (Range)(N⋅m): 20 to Less than 50, Type: Rotary Actuator Both Sides Shaft Outputs, Main Body Shape: Round Shape, Operation Method: Double Vane, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.1 to Less than 1, Tube Nominal Diameter: 63, Valves: Not Provided, Allowable Kinetic Energy(J): 0.16, Operating
Magnet: Built-in, Mounting: Front Flange, Bore Size: 50mm, Thread: M5x0.8 (20-25 Bore); Rc (32-100 Bore), Stroke: 50mm, Body Option: Rubber Bumper, Locking Direction: Forwarding Stroke Lock, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, 0.5M, Lead Wire or Prewired Connector: 5m, Number: -
Magnet: Built-in, Mounting: Double Clevis, Bore Size: 40mm, Thread: G, Stroke: 15mm, Body Option: Standard, Locking Direction: Retracting Stroke Lock, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, 0.5M, Lead Wire or Prewired Connector: 5m, Number: -