46) I.D.holding :12.6 (56) MHK2-20D 20 10 16 26 8.3 O.D. holding:18.0 (80) I.D. holding :19.3 (86) MHK2-25D 25 14 19 33 15.5 MHK2-12S 120 12 2.0 (9) 4 9 13 2.7 Normally open Normally closed MHK2-16S 16 5.2 (23) 6 14.6 20.6 4.0 MHK2-20S 20 7.6 (34) 10 16 26 8.4 L1 MHK2-25S 25 13.0 (58) 14 19 33 15.6 Single acting L2 MHK2-12C 12 2.7 (12) 4 9 13 2.7 MHK2-16C 16 5.6 (25) 6 14.6 20.6 4.1 MHK2-20C
Speed controller Cylinder Solenoid valve Tube Silencer Maximum return speed mm/s 100 200 300 6 ASD230FG CJ2 VJ500 TU0604 1m AN11001 10 16 Cylinder size 20 ASD330FG CM2 VZ500 TU0604 1m AN11001 25 Cylinder size 32 Values for pressure of 0.5MPa and temperature of 20C.
(Variation: 10%) *7 The value when there is an ambient temperature of 20C and when the rated voltage is applied. The value depends on the ambient environment.
O.D. 1/8" 5/32" 5/32" 3/16" 1/4" 5/16" 3/8" 3/8" 1/2" 1/4" 5/16" 3/16" 1/4" 1/8" 5/32" Inch size 3/8" 5/16" 3/16" 1/4" Flow Direction Symbols on Body Meter-out type Meter-in type Flow rate (l/min (ANR)) Controlled flow (Free flow) 100 180 230 260 390 460 660 790 920 1580 1710 Symbol Effective area (mm2) 1.5 2.7 3.5 4 6 7 10 12 14 12 26 Note) Flow rate values are measured at 0.5 MPa and 20C
AFF75B-N20D-T 424 2 8.67 0.39 1.46 23.15 AFF-EL75B 18.64 AFW675-N20-E1 675 2 8.67 0.39 2.56 11.02 E1702-E1 18.64 AFW954-N25-E1 954 2 1/2 8.67 0.39 2.56 25.35 E3127-E1 18.64 AFW1300-N30-E1 1300 3 8.67 0.39 2.56 34.17 E3783-E1 18.64 AFW1530-N30-E1 1530 3 8.67 0.39 2.56 41.89 E3843-E1 AFW675-AFW1530 Filter Performance (ISO8573.1) Particle Size CL.3 Oil Content CL.4 Flow @ 0.7MPa (100 PSI) & 20C
The minimum bending radius indicates the value, at which the tubing gets bended at the temperature of 20C.
Please contact SMC for further details. 2 Based on the JIS B 8419:2010 dynamic performance test (Coil temperature: 20C, pressure: 0.5 MPa, at the rated voltage) 3 Impact resistance: No malfunction occurred when it was tested in the axial direction and at a right angle to both the main valve and the armature in both an energized and de-energized state, once for each condition.
NO OFF n-2 n-1 Real-time flow rate Flow rate conversion Normal condition: 0C, 101.3 kPa, dry air Standard condition: 20C, 101.3 kPa, 65%RH (ANR) Switchable between these conditions.
response frequency Green LED (stable detection) Red LED (unstable detection) Red LED (lights up when ON) Indicator light Ambient temperature 10 to 55C 25 to 70C Environmental resistance Ambient humidity 45 to 85% RH Power line: 240Vp, pulse width of 0.5s Noise resistance Temperature characteristics Voltage characteristics Detecting distance fluctuation Within +15/10% of detecting distance at 20C
TISA01BU-20X4 Made to Order eThe value of the min. bending radius is at a temperature of 20C and O.D. variable rate 10% max.
Flow rate conversion PF2 NO OFF n-2 n-1 High flow rate Basic state: 0C, 101.3 kPa Standard state: 20C, 101.3 kPa, 65%RH (ANR) Switchable between these states.
/32" 3/16" 5/16" 3/8" 1/2" 5/32" 5/16" 3/8" 3/16", 1/4" Flow rate (L/min (ANR)) 180 230 100 260 390 660 790 460 920 1580 1710 Controlled flow Free flow Sonic conductance dm3/(sbar) 0.54 0.7 0.3 0.8 1.2 1.4 2 2.4 2.8 4.8 5.2 Critical pressure ratio Controlled flow 0.25 0.3 0.25 0.25 0.2 Free flow 0.2 0.3 0.2 0.3 0.4 Note) Flow rate values are at a pressure of 0.5 MPa and a temperature of 20C
type Meter-in type Inch size 3/16" 5/16" 3/8" Indication symbol 1/4" Flow rate (L/min (ANR)) 100 180 230 260 390 460 660 790 920 1580 1710 Controlled flow Free flow Sonic conductance dm3/(sbar) 4.4 4.8 0.28 0.50 0.64 0.72 1.1 1.3 1.8 2.2 2.6 Symbol Critical pressure ratio 0.2 0.25 0.3 0.25 0.25 Controlled flow Free flow 0.4 0.2 0.3 0.2 0.3 Note) Flow rate values are measured at 0.5 MPa and 20C
When the ambient temperature is 20C 5C and rated voltage is applied. Changing coils from AC to DC and vice versa is impossible, because of different core shapes. VXD21 0, 22 0, 23 0 are possible to exchange coil from AC to DC, but impossible from DC to AC. (Hum sound may generate because of no shading coil for DC.)
The value of the max. operating pressure is at a temperature of 20C. Refer to the burst pressure characteristics curve for other temperatures. Furthermore, abnormal temperature rises caused by adiabatic compression may result in the burst of the tube.
(Coil temperature: 20C, at rated voltage, without surge suppressor) Note 2) When operating the locking type manually, apply torque of 0.2 Nm or less. Note 3) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
The value of the max. operating pressure is at a temperature of 20C. Refer to the burst pressure characteristics curve for other temperatures. Furthermore, abnormal temperature rises caused by adiabatic compression may result in the burst of the tube.
The value of the max. operating pressure is at a temperature of 20C. Refer to the burst pressure characteristics curve for other temperatures. Furthermore, abnormal temperature rises caused by adiabatic compression may result in the burst of the tube.
10 6 (m 2 ) VX32 AC (Full wave rectification) 50/60 10 8.5 60 1 3 5 0.08 1.5 1.0 0.6 220 1.9 VX311 -00 DC 8.5 60 11 60 9.5 50 1 3 5 0.16 0.5 0.3 220 3.8 VX312 -00 50 55 22 60 47 18 AC 0.6 370 VX3225-00 2.2 0.19 4.6 VX33 1.0 530 VX3325-00 AC (Full wave rectification) 50/60 14 11.5 60 1 3 5 0.24 DC 11.5 60 0.3 0.2 5.8 220 1.0 VX313 -00 Note) They are values in an ambient temperatue of 20C