SMC Corporation of America
Elite Part Number Search
Search Results "CDQ2B100-25+25D-XC11"

Magnet: D (Built-in Magnet), Mounting: B (Through-hole, Standard), Bore Size: 50mm, Stroke: 25mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.

Magnet: None, Mounting: A (Both Ends Tapped), Bore Size: 25mm, Stroke: 25mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: XC6 (Stainless Steel)

Magnet: None, Mounting: B (Through-hole, Standard), Bore Size: 25mm, Stroke: 25mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: XC6 (Stainless Steel)

Magnet: None, Mounting: B (Through-hole, Standard), Bore Size: 32mm, Stroke: 25mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: XC6 (Stainless Steel)

Magnet: None, Mounting: B (Through-hole, Standard), Bore Size: 63mm, Stroke: 25mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: XC35 (w/Coil Scrapper)

Magnet: None, Mounting: L (Foot), Bore Size: 32mm, Stroke: 25mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: XC35 (w/Coil Scrapper)

Magnet: None, Mounting: L (Foot), Bore Size: 63mm, Stroke: 25mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: XC4 (w/Heavy Duty Scrapper)

Magnet: D (Built-in Magnet), Mounting: A (Both Ends Tapped), Bore Size: 32mm, Stroke: 25mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: XC35 (w/Coil Scrapper)

Magnet: None, Mounting: B (Through-hole, Standard), Bore Size: 25mm, Stroke: 25mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: XC4 (w/Heavy Duty Scrapper)

Magnet: D (Built-in Magnet), Mounting: B (Through-hole, Standard), Bore Size: 40mm, Stroke: 25mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.

Magnet: None, Mounting: A (Both Ends Tapped), Bore Size: 16mm, Stroke: 25mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: XC6 (Stainless Steel)

Magnet: None, Mounting: A (Both Ends Tapped), Bore Size: 20mm, Stroke: 25mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: XC6 (Stainless Steel)

Magnet: None, Mounting: B (Through-hole, Standard), Bore Size: 20mm, Stroke: 25mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: XC6 (Stainless Steel)

Magnet: D (Built-in Magnet), Mounting: A (Both Ends Tapped), Bore Size: 40mm, Stroke: 25mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: XC6 (Stainless Steel)

Magnet: None, Mounting: D (Doulbe Clevis), Bore Size: 12mm, Stroke: 25mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: XC6 (Stainless Steel)

Magnet: None, Mounting: A (Both Ends Tapped), Bore Size: 12mm, Stroke: 25mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: XC6 (Stainless Steel)

Magnet: None, Mounting: B (Through-hole, Standard), Bore Size: 20mm, Stroke: 25mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: XC4 (w/Heavy Duty Scrapper)

Magnet: D (Built-in Magnet), Bore Size: 20mm, Thread Type: Rc (or M5 x 0.8), Stroke: 25mm, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in), Mounting: B [Through Hole, Both Ends Tapped (Standard)], Bore Size: 25mm, Stroke: 25mm, Option: Standard (Rod End Female Thread), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in), Mounting: B [Through Hole, Both Ends Tapped (Standard)], Bore Size: 25mm, Stroke: 25mm, Option: Standard (Rod End Female Thread), Auto Switch: M9PV--Solid State, Gen. Purpose, 3 Wire PNP, Vertical, 0.5M, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)