Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: M9P, Lead Wire Length(m): 0.5, The number
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: Without auto switch, Lead Wire Length
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without built-in magnet, Auto Switches: Without auto switch, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: High speed / high frequency, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: NPT
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: High speed / high frequency, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: High speed / high frequency, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: High speed / high frequency, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: High speed / high frequency, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: High speed / high frequency, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.08 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: Without auto switch
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.08 to 1.0, Specification: Built-in magnet, Port thread type: NPT, Auto Switches: Without auto switch
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.08 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: Without auto switch
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Environment, Applications: Clean Room, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: Without auto switch, Lead Wire Length(m): N/A,
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Clean Room, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: Without auto switch, Lead Wire Length(m): N/A
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Auto Switches: None, Lead
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Auto Switches: None, Lead
Bearing Type: Slide Bearing, Bore Size: 12mm, Thread Type: Rc; Bore Size 12, 16: M5 x 0.8, Stroke: 125mm, Stroke Adjustment: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: Low Speed Cylinder, 5 to 50mm/s