Magnet: D (Built-in Magnet), Shaft Type: W (Double Shaft with Single Flat), Size: 30 mm, Rotating Angle: 180 (180°), Vane Type: S (Single Vane), Connecting Port Location: Side Ported, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Electrical Entry/Lead Wire Length: L (3m)
Magnet: D (Built-in Magnet), Size: 20, Rotating Angle: 90 (90°), Vane Type: D (Double Vane), Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Electrical Entry/Lead Wire Length: L (3m)
Magnet: D (Built-in Magnet), Size: 15, Rotating Angle: 180 (180°), Vane Type: S (Single Vane), Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal
Magnet: D (Built-in Magnet), Size: 40, Rotating Angle: 180 (180°), Vane Type: S (Single Vane), Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Electrical Entry/Lead Wire Length: L (3m), Number: S (1 pc.)
Magnet: D (Built-in Magnet), Size: 30, Rotating Angle: 270 (270°), Vane Type: S (Single Vane), Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Electrical Entry/Lead Wire Length: L (3m)
Magnet: D (Built-in), Mounting: R (Front Block), Bore Size: 044 (7/16"), Stroke: 0050 (1/2"), Cushion: w/o Rubber Bumper, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: MAPC (1.0m Cord Length, M8-3 Pin Connector), Number: S (1 pc.)
Magnet: D (Built-in), Mounting: R (Front Block), Bore Size: 075 (3/4"), Stroke: 0150 ( 1 1/2"), Cushion: w/o Rubber Bumper, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector)
Magnet: D (Built-in), Mounting: R (Front Block), Bore Size: 075 (3/4"), Stroke: 0150 ( 1 1/2"), Cushion: w/o Rubber Bumper, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)
Magnet: D (Built-in), Mounting: R (Front Block), Bore Size: 075 (3/4"), Stroke: 0500 (5"), Cushion: C (Rubber Bumper), Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)
Magnet: D (Built-in), Mounting: R (Front Block), Bore Size: 075 (3/4"), Stroke: 0600 (6"), Cushion: C (Rubber Bumper), Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: R (Front Block), Bore Size: 106 (1 1/16"), Stroke: 0200 (2"), Cushion: C (Rubber Bumper), Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: R (Front Block), Bore Size: 044 (7/16"), Stroke: 0400 (4"), Cushion: C (Rubber Bumper), Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal
Magnet: D (Built-in), Mounting: R (Front Block), Bore Size: 075 (3/4"), Stroke: 0500 (5"), Cushion: w/o Rubber Bumper, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal
Magnet: D (Built-in), Mounting: R (Front Block), Bore Size: 106 (1 1/16"), Stroke: 0800 (8"), Cushion: C (Rubber Bumper), Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)
(P.29~32) < Applicable Auto switches > Solid state switch D-M9N(V)M9P(V)M9B(V) D-M9NW(V)M9PW(V)M9BW(V) D-M9NA(V)M9PA(V)M9BA(V) Reed switch D-A90(V)A93(V)A96(V) How to mount and move the auto switch Fig. 8 Attach the auto switch mounting bracket to the cylinder tie rod so that the bottom surface of the auto switch mounting bracket contacts the cylinder tube.
(P.20) < Applicable Auto switches > Solid state switch D-M9N(V)M9P(V)M9B(V) D-M9NW(V)M9PW(V)M9BW(V) D-M9NA(V)M9PA(V)M9BA(V) Reed switch D-A90(V)A93(V)A96(V) How to mount and move the auto switch Fig. 8 Note 1) For the tightening of the mounting screws (M2.5), use a precision screwdriver with a handle diameter of approximately 5 to 6 mm.
(P.27 to 29) < Applicable Auto switches > Solid state switch D-M9N(V)M9P(V)M9B(V) D-M9NW(V)M9PW(V)M9BW(V) D-M9NA(V)M9PA(V)M9BA(V) Reed switch D-A90(V)A93(V)A96(V) How to mount and move the auto switch Fig. 8 Attach the auto switch mounting bracket to the cylinder tie rod so that the bottom surface of the auto switch mounting bracket contacts the cylinder tube.
Recommended tool: Description Part number Wire stripper D-M9N-SWY : For 2-wire type auto switches, a round wire stripper (2.0) can be used. -9No.D-S-OMI0002-C Operating Environment Caution (1) Do not use in a location where surges are generated.
(D-M9 only) Operation Environment Recommended Tool Description Model Wire stripper D-M9N-SWY * Stripper for a round cable (2.0) can be used for a 2-wire type cable. Warning (1) Never use in an atmosphere with explosive gases. Auto switches are not designed with explosion-proof construction. Never use in an atmosphere containing explosive gas since this may cause a serious explosion.
(D-M9 only) Operation Environment Recommended Tool Description Model Wire stripper D-M9N-SWY * Stripper for a round cable (2.0) can be used for a 2-wire type cable. Warning (1) Never use in an atmosphere with explosive gases. Auto switches are not designed with explosion-proof construction. Never use in an atmosphere containing explosive gas since this may cause a serious explosion.