Body Size: 40, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 04 (1/2), Option: B (Assembly of a Bracket and Set Nuts), Semi-Standard 1: 12 (1 + 2), Semi-Standard 2: Standard
Body Size: 40, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 04 (1/2), Option: BG (B + G), Semi-Standard 1: 12 (1 + 2), Semi-Standard 2: Standard
Body Size: 40, Thread: N (NPT), Port Size: 04 (1/2), Option: G (For Sizes 10, 20, 30, 40 Round Type Pressure Gauge w/Limit Indicator; For For Size 10: Round Type Pressure Gauge w/o Limit Indicator ), Semi-Standard 1: 12 (1 + 2), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 40, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 04 (1/2), Option: BD (B + D), Semi-Standard 1: 12 (1 + 2), Semi-Standard 2: R (Flow Direction: Right to Left)
Body Size: 40, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 04 (1/2), Option: BDG (B + D + G), Semi-Standard 1: 12 (1 + 2), Semi-Standard 2: R (Flow Direction: Right to Left)
Body Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Option: DG (D + G), Semi-Standard 1: 12 (1 + 2), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: G (For Sizes 10, 20, 30, 40 Round Type Pressure Gauge w/Limit Indicator; For For Size 10: Round Type Pressure Gauge w/o Limit Indicator ), Semi-Standard 1: 12 (1 + 2), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Option: CG (C + G), Semi-Standard 1: 12 (1 + 2), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient & fluid temperature: -10 to 50°C VQZ2000 VALVE, SOL 4/5-PORT.
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient & fluid temperature: -10 to 50°C VQZ1000 VALVE, SOL 4/5-PORT.
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient & fluid temperature: -10 to 50°C VQZ3000 VALVE, SOL 4/5-PORT.
Plug-in type SY3000/5000/7000 series part numbers: SYS□□00, SY□□30, SY□□01, and SY□□31
Existing SY3000/5000/7000/9000 series part numbers: SY□□20, SY□□40, and SY□□45
The part numbers of the gasket assemblies for use between the plug-in type SY3000/5000/7000 series valves and manifold are as follows.
Body Size: 20, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 02 (1/4), Option: Standard, Attachment: S (Pressure Switch), Semi-Standard 1: 12 (1 + 2), Semi-Standard 2: Standard
Body Size: 20, Thread: N (NPT), Port Size: 02 (1/4), Option: G (Size 20 25, 30, 40: Round Type Pressure Gauge w/Limit Indicator; Size 10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: Standard, Semi-Standard 1: 12 (1 + 2), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 20, Thread: N (NPT), Port Size: 02 (1/4), Option: G (Size 20 25, 30, 40: Round Type Pressure Gauge w/Limit Indicator; Size 10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: S (Pressure Switch), Semi-Standard 1: 12 (1 + 2), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 25, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 03 (3/8), Option: CG (C + G), Attachment: T (T-Interface), Semi-Standard 1: 12 (1 + 2), Semi-Standard 2: R (Flow Direction: Right to Left)
Body Size: 25, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 03 (3/8), Option: C (N.C. Float Type Auto Drain), Attachment: T (T-Interface), Semi-Standard 1: 12 (1 + 2), Semi-Standard 2: R (Flow Direction: Right to Left)
Body Size: 30, Thread: N (NPT), Port Size: 02 (1/4), Option: D (N.O. Float Type Auto Drain), Attachment: Standard, Semi-Standard 1: 12 (1 + 2), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 30, Thread: N (NPT), Port Size: 02 (1/4), Option: DG (D + G), Attachment: Standard, Semi-Standard 1: 12 (1 + 2), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient & fluid temperature: -10 to 50°C 3 PORT SOLENOID VALVE.