Quick exhaust Normal operation High speed supply B 1/2 PP PA C D PA PP 1(P) 2 2(A) 1 1/2 PP = approx.
Port 3 (R) 1/4 (P1) Refer to page 2449. 2 x port size Port 2 (A),1 (P) 2 x d Mounting hole A (Air operated) For bracket mounting Max. O Min.
Quick exhaust Normal operation High speed supply B 1/2 PP PA C D PP PA 1(P) 2 2(A) 1 1/2 PP = approx.
gauge G36-10-01 1 MPa Description Part no.
Fig.1-3 shows the location of the communication port. 1 6 Serial communication connector D sub 9 female pin (socket) type 9 5 1 14 Contact input / output signal connector D sub 25 female pin (socket) type 25 13 Fig.1-3 Communication port 1.3 Communication port HRL Series 1-4 HRX-OM-W069 Chapter 1 Read before using 1.4 Touch panel flow Press the [Comm.
Series VS R8b S RUBBER SEAL/METAL SEAL SERIES VSR8/VSS8 2-position Single solenoid (FG-S) (A)(B) 4 2 5 1 3 (EA)(P)(EB) Double solenoid (FG-D) (Metal) (A)(B) 4 2 5 1 3 (EA)(P)(EB) Double solenoid (FG-D) (Rubber) (A)(B) 4 2 5 1 3 (EA)(P)(EB) 3-position Closed center (FHG-D) (A)(B) 4 2 5 1 3 (EA)(P)(EB) Exhaust center (FJG-D) (A)(B) 4 2 5 1 3 (EA)(P)(EB) Pressure center (FIG-D) (A)(B) 4 2 5
16DD-M9(W,A)V D-P3WA 56mm Nm D-M9(V) D-M9W(V) D-M9A(V) D-P3DWA 0.050.15 -12- (mm) L1 L2 L3 L4 L5 L6 16 5 MHM-16D 1 1 1 1 MHM-25D 36 34 MHM-32D 50 24 MHM-50D 23 25 80 41 / 3 NPN 3 PNP PLC PLC 2 2 PLC PLC PLC PLC -13- AND(),OR() *50ms 3 NPN OR 3 NPN AND 1 1 1 2 2 2 3 PNP AND 3 PNP OR 1 1 1 2 2 2 2 AND 2 OR 2 AND ON , 2 ON 20V 2 OR OFF OFF 1 1 ON 2 2 ON =-2 OFF =2
Approx. 1.1 mm Insulator Colours Brown, blue, black, white Sheath Finish O.D. 4 -53No.PF-OMX0007-A Characteristics data Flow rate/Analogue output 0 L/min A 2 B 0 L/min C 2 D Voltage output (1 to 5 V) 1 1 V 1.04 V 5 V Voltage output (0 to 10 V) 1, 3 0 V 0.1 V 10 V Current output 1 4 mA 4.16 mA 20 mA Models Minimum value of rated flow range *4 Maximum value of rated flow range PF3A701H 10 L
Note Weight Lead wire and M12 connector LFE-1-A3 Lead wire length 3 m Approx. 175 g Option Part no. Note Weight Bracket LFE-1-D Tapping screw for LFE1 (3 x 10), 4 pcs. Approx. 45 g LFE-2-D Tapping screw for LFE2 (3 x 10), 4 pcs. Approx. 70 g LFE-3-D Tapping screw for LFE3 (3 x 10), 4 pcs.
(SW1) (SW1) (SW2-3, SW2-4) (SW2-3, SW2-4) 0 1 0 17 1 2 1 18 2 3 2 19 3 4 3 20 4 5 4 21 5 6 5 22 6 7 6 23 ON ON 7 8 7 24 8 9 8 25 1 2 3 4 1 2 3 4 9 10 9 26 A 11 A 27 B 12 B 28 C 13 C 29 D 14 D 30 E 15 E 31 F 16 F 32 -13- Auxiliary axis number Auxiliary axis number Axis selection rotary switch Axis selection rotary switch Control Control setting switch setting switch axis No. axis No.
Fittings & Tubing Air Cylinders Rotary Actuators How to Order Manifold 10 SS5Q13 08 FD2 D CE-compliant Clean series Nil Q CE-compliant Stations 1 station 01 1(P), 3(R) port size 24 Note) 24 stations Nil 1(P), 3(R) port 8 One-touch fittings 1(P), 3(R) port 5/16" One-touch fittings Note) The maximum number of stations depends on the type of electrical entries. 00T Option Nil 02 to 24 Note
(16 outputs) 0 1 Digital output unit EX600-DYF (16 outputs) 0 1 EX600-DME (8 inputs/8 outputs) 1 1 Digital I/O unit EX600-DMF (8 inputs/8 outputs) 1 1 Analog input Unit EX600-AXA 2 (1 word / 1 channel) 0 (2 channels) (2 channels) 0 2 Analog output Unit EX600-AYA (1 word / 1 channel) Analog I/O Unit EX600-AMB 2 2 (2/2 channels) (1 word / 1 channel) (1 word /1 channel) Note) 1 word is equivalent
Accuracy [%F.S.] 50% 50% 50% 40% 40% 40% With 1 1/4" connected With 1 1/2" connected 30% 30% 30% With 3/4" connected Elbow piping (2") Elbow piping (1 1/2") 20% 20% 20% Elbow piping (1") 10% 10% 10% 3% 3% 3% 8 7 6 5 4 3 2 1 0 0% 0% 0% 8 7 6 5 4 3 2 1 0 8 7 6 5 4 3 2 1 0 Straight section [d] Straight section [d] Straight section [d] Straight When piping with diameter smaller than the straight
side Stations12345678n U side Negative common N Stations are counted from station 1 on the D-side.
.: IZ-OMR0035 PRODUCT NAME Ionizer MODEL / Series IZF21/31 Series 1 Doc. No.: IZ-OMR0035 Contents Safety Instructions . 3 1. How to Order. 8 1-1. Ionizer . 8 1-2. Accessories. 8 1-3. Option . 10 2. Procedures to Operation . 10 3. Installation and Wiring . 11 3-1 Installation . 11 3-1-1. Precautions for Installation . 11 3-1-2. Installation of Ionizer . 12 3-2. Wiring . 13 3-2-1.
1 w !2 y u !3 !4 i !5 !9 !6 !7 @0 @1 !8 No.
1 V or less -19No.PS-OMX1005 -C NPN open collector 1 output Max. 28 V, 80 mA Residual voltage 1 V or less Analog voltage output Output impedance approx. 1 k -D NPN open collector 1 output Max. 28 V, 80 mA Residual voltage 1 V or less Analog current output Max. load impedance 300 at 12 V power supply voltage 600 at 24 V power supply voltage Min. load impedance 50 -E PNP open collector
VNA VNA 2 1 2 1 2 1 VNA VNA D-X Technical Data 1177
Tube deformation ratio at the minimum bending radius = L D 2d 1 x 100 Mandrel Here, : Deformation ratio (%) d : Tube O.D.
100 Rotary type Connection Applicable model Pressure gauge Air Electric Symbol IP800-00 IP800-01 Symbol Pressure Nil Rc1/4 G1/2 0 None M Rc1/4 M201.5 1 0.2 MPa N Rc1/4 1/2NPT 2 0.3 MPa 1 1/4NPT G1/2 3 1.0 MPa 2 1/4NPT M201.5 3 1/4NPT 1/2NPT 4 G1/4 G1/2 Construction Note 1) 5 G1/4 M201.5 0 No terminal box 6 G1/4 1/2NPT With terminal box (Exsd BT5) TIIS (Japan) explosion-proof