As the circulating fluid temperature is within the set range of "AS.06", "AS.06" alarm monitoring starts. Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts.
Load factor: ((Load weight x 9.8)/Theoretical force) x 100% Conditions Series CJ2 Series CM2 6 x 1 m AS3301F-06 12 x 1 m AS4001F-12 AN200-02 AS2301F-06 AN110-01 Series MB/CA2 Series CJ2 Series CM2 Series MB/CA2 Body ported Tubing bore x Length Speed controller Silencer Base mounted Tubing bore x Length Speed controller Silencer AN200-02 AN3301F-06 AS1301F-06 6 x 1 m AS3001F-06 SYJ7120-01
AL10, 20 AL30, 40, 40-06 AL50, 60 1 8 Body Zinc die-cast Aluminum die-cast Platinum silver Housing Platinum silver Aluminum die-cast Replacement parts Part no. Material Description No.
3/4 1 Thread type ON-flow range Note 1) IF30 is available for 06.
Port Size: 0 (ZM Ejector Mounting), Switch & Voltage: 21 (Reed Switch/100VAC)
Type: 000 (Lever Type Feedback), Pressure Gauge: 2 (0.3MPa), Construction: 1 (w/Terminal Box)
Type: 100 (Rotary Type), Pressure Gauge: 2 (0.3MPa), Construction: 1 (w/Terminal Box)
Model: 2000, Output Pressure: 0.1MPa, Terminals: Conduit, Thread: Rc(PT), Input Signal: 4~20mA, Port Size: 2 [1/4" (2000,4000)], Accessory: None, Pressure Gauge: Indication of psi and k
Type: Lever Type Feedback, Pressure Gauge: 0.3MPa, Construction: w/Terminal Box, Accessories: -, Connection: -
Type: Rotary Type, Pressure Gauge: 0.3MPa, Construction: w/Terminal Box, Accessories: -, Connection: -
Body Size: 32, Pilot Type: Air Operated, Port: 1/4, Thread: Rc, Voltage: None, Electrical Entry: None, Light/Surge Voltage Suppressor: None, Manual Override: Non-locking Push Style or None, Option: -
Body Size: 32, Pilot Type: 0 (Air Operated), Port: 02 (1/4), Thread: Rc, Voltage: None, Electrical Entry: None, Light/Surge Voltage Suppressor: None, Manual Override: Non-locking Push Style or None
Body Size: 22, Pilot Type: 0 (Air Operated), Port: 02 (1/4), Thread: Rc, Voltage: None, Electrical Entry: None, Light/Surge Voltage Suppressor: None, Manual Override: Non-locking Push Style or None
Port Size: ZM Ejector Mounting, Switch & Voltage: Reed Switch/100VAC, Lead Wire Length: -
Body Size: 22, Pilot Type: Air Operated, Port: 1/4, Thread: Rc, Voltage: None, Electrical Entry: None, Light/Surge Voltage Suppressor: None, Manual Override: Non-locking Push Style or None, Option: -
Function: 2 Position Double, Body Option: Class 2, Piping: Side, Port Size: 1/4, Voltage: 100VAC 50/60HZ, Electrical Entry: -, Thread: -, Option: -
Function: 2 Position Single, Body Option: Class 2, Piping: Side, Port Size: 1/4, Voltage: 100VAC 50/60HZ, Electrical Entry: -, Thread: -, Option: -
Function: 2 Position Single, Body Option: Class 3, Piping: Side, Port Size: 1/4, Voltage: 100VAC 50/60HZ, Electrical Entry: -, Thread: -, Option: -
Function: 3 Position Exhaust Center, Body Option: Class 3, Piping: Side, Port Size: 1/4, Voltage: 100VAC 50/60HZ, Electrical Entry: -, Thread: -, Option: -
Body Option: 3/8 Basis, Port Size: 1/4, Voltage: 100VAC 50/60HZ, Lead Wire: -, Option: -, Thread: -