Do not connect the white wire of the sensor to c of the display unit. View A Terminal block number 4 3 2 1 1 2 3 4 5 6 7 8 8 7 6 5 Series PF2D For Deionized Water and Chemicals Digital Flow Switch Functions/PF2D Refer to the operation manual how to set and to operate. Output types Flow rate measurement selection Real-time flow rate and accumulated flow rate can be selected.
Reconfiguring the operation mode, as well as the zero and span adjustments, are easy to do in the field. INSTALLATION B D Installation Transmission Din & Feed-back lever Fig. SINGLE-ACTING ACTUATOR SIGNAL PRE-Y%i-rpur SIGNAL RANGE INSTALLATION STYLE IREF. FIG. 1) OUT 1 OUT2 Direct ?
(Refer to the catalog contents for details, as some types of connectors do not meet these standards.) Power consumption: 0.6W (Current: 25mA, 24VDC) A relay output module is available for control of devices up to 110VAC, 3A.
(Inlet air pressure: 0.7 MPa, Inlet air temperature: 20C) HA How to Order AT ID 20 02 0 ID AMG ID400 Option B Bracket Z Adsorbent for low dew point Basic size AFF 20 30 40 60 Port size AM ID200 02 B 04 06 1 4 B 1 2 B 3 4 Nil Rc Thread type Misc.
Do not service or attempt to remove product and machinery/equipment until safety is confirmed. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed.
(Rubber, Metal sliding parts: Fluorine coated) Non-greased specification H/DL L/LL Single plug With check valve Single socket Metal part: Stainless steel 304, Rubber material: Fluororubber (Special FKM) Material KC With male thread sealant Seal Note 1) Do not use the S couplers with a leak tester or for vacuum retention because they are not guaranteed for zero leakage.
Example) AR30K-03BE-1NR-B w e V q Body size 20 25 30 40 50 60 Symbol Description V w With backflow function Nil Without backflow function K Note 1) With backflow function + V e Pipe thread type Nil Rc N NPT F G + 01 1/8 02 1/4 03 3/8 04 1/2 06 3/4 10 1 V r Port size + a Mounting Nil Without mounting option B Note 3) With bracket H With set nut (for panel mount) + Nil Without pressure
When the line is stopped, do not adjust or set the differenital pressure, as it could cause the differential adjustment valve to break. 3. When setting the pressure differential, if there is a fluctuation in the operating flow rate, set the pressure differential at the lower flow rate range.
Do not use the regulator with flow exceeding the Max. flow indicated in Flow Rate Characteristics as this can cause failure in pressure adjustment. Bleed port Component Parts Knob locking screw No.
Do not service or attempt to remove product and machinery/ equipment until safety is confirmed. 1. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed. 2.
NTJ-015A NT-02 NT-04 NT-05 12 M5 x 0.8 4 8 9.2 7.8 H B 20 5 13 15.0 12.5 M8 x 1.25 32, 40 8 22 25.4 21.0 M14 x 1.5 50, 63 11 27 31.2 26 M18 x 1.5 Electrical Wiring Output type The output signal of the stroke reading cylinder is A/B phase difference output (open collector output) as shown in the figure below.
axis C shaped 5 0.030 0.060 0.030 0.060 0.040 0.076 0.040 0.076 0.040 0.076 0.050 0.093 0.050 0.093 0.065 0.117 12 16 20 25 32, 40 50, 63 80 100 4.8 4.8 7.6 9.6 9.6 13.4 17 21 12 16 20 25 32, 40 50, 63 80 100 IY-G012 IY-J015 IY-G02 IY-G03 IY-G04 IY-G05 IY-G08 IY-G10 M5 X 0.8 M6 X 1 M8 X 1.25 M10 X 1.25 M14 X 1.5 M18 X 1.5 M22 X 1.5 M26 X 1.5 NTJ-015A NT-015A NT-02 NT-03 NT-04
(Inlet air pressure: 0.7 MPa, Inlet air temperature: 20C) HA How to Order AT ID 20 02 0 ID AMG ID400 Option B Bracket Z Adsorbent for low dew point Basic size AFF 20 30 40 60 Port size AM ID200 02 B 04 06 1 4 B 1 2 B 3 4 Nil Rc Thread type Misc.
NTJ-015A NT-02 NT-04 NT-05 12 7.8 M5 x 0.8 9.2 8 4 H B 20 12.5 15.0 13 5 M8 x 1.25 32, 40 21.0 25.4 22 8 M14 x 1.5 50, 63 26 31.2 27 11 M18 x 1.5 Electrical Wiring Output type The output signal of the stroke reading cylinder is A/B phase difference output (open collector output) as shown in the figure below.
Do not indicate suffix N for no lead wire on D-A3/A44/G39/K39 models.
Do not remove the hexagon socket set screw on the side of the rod. Be aware that if the hexagon socket set screw is removed with compressed air supplied to the cylinder, an internal steel ball could fly out or the compressed air could be discharged, leading to injury to humans or damage to peripheral equipment. Part no.: CQP2B50-57D CQP2B50-75D with 18 mm width spacer inside.
/Single Unit), Solenoid Valve Option: Brass Body (Aluminum for Air Type), NBR Seal, Class B, Suffix: Standard, Port Size: 04 (1/2), Thread Type: F (G), Voltage: 5 (24VDC), Lead Wire: DO (DIN Connector without Connector)
/Single Unit), Solenoid Valve Option: H (SUS Body, FKM Seal, Class B), Suffix: Standard, Port Size: 04 (1/2), Thread Type: F (G), Voltage: 5 (24VDC), Lead Wire: DO (DIN Connector without Connector)
/Single Unit), Solenoid Valve Option: Brass Body (Aluminum for Air Type), NBR Seal, Class B, Suffix: Standard, Port Size: 04 (1/2), Thread Type: F (G), Voltage: 5 (24VDC), Lead Wire: DO (DIN Connector without Connector)
/Single Unit), Solenoid Valve Option: A (Brass Body, FKM Seal, Class B), Suffix: Standard, Port Size: 04 (1/2), Thread Type: N (NPT), Voltage: 5 (24VDC), Lead Wire: DO (DIN Connector without Connector)