SMC Corporation of America
Elite Part Number Search
Search Results "VV2Q22-03-DO"

Do not use in an atmosphere where corrosive gases, chemicals, sea water, water or water steam is present. 2. Do not expose the product to direct sunlight for an extended period of time. 3. Do not operate in a location subject to vibration or impact. 4. Do not mount the product in locations where it is exposed to radiant heat. 5.

Do not use this product with a fluid other than compressed air (e.g. oxygen, hydrogen, inflammable gas, mixed gas, etc.). -Do not use compressed air which includes chemicals, organic solvents, or corrosive gases, etc. It may lead to damage or malfunction. Do not use for caisson shield, breathing, medical purposes, air blow to any medicines and foods that enter the human body.

Example Warning Mounting 0.1 0.2 0.3 Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. 2. Insert the cable through the conduit and install the wires according to the terminal board layout below. Manifold expansion 0.4 0 Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids.

Do not touch the span calibration trimmer except when performing span calibration. Touching the trimmer may cause generation of an error in the measured pressure. Also do not turn it too hard (0.3 Nm or less) or press it too hard (5 N or less). 7. Use a soft cloth to wipe the blot off of the body.

Do not use the valves in an atmosphere having corrosive gases, chemicals, salt water, water, steam, or where there is direct contact with any of these. 2. Do not use in locations subject to vibration or impact. 3. Do not use in locations where radiated heat will be received from nearby heat sources. 4.

Do not touch the span calibration trimmer except when performing span calibration. Touching the trimmer may cause generation of an error in the measured pressure. Also do not turn it too hard (0.3 Nm or less) or press it too hard (5 N or less). 7. Use a soft cloth to wipe the blot off of the body.

Do not attempt to rotate the connector, as it is not rotatable.

Do not use until you can verify that equipment can operate properly. Verify correct mounting by suitable function and leakage inspections after air and power are connected following mounting, maintenance or conversions. 2. Do not drop or bump. Do not drop, bump or apply excessive impact (1000 m/s2) when handling.

Do not scratch or gouge the sliding part of the piston rod or guide rod. This will cause air leakage or malfunction due to damage of the seals. 2.

Conditions for mechanical operation Do not move the mechanical operation beyond the operating limit position, as this could damage the mechanical valve itself and lead to equipment malfunction. Actuator stroke Operate the mechanism within the stroke range that has been obtained through the formula given below. (Do not move beyond the operating limit position.)

Do not use tools, such as pliers, to rotate the knob. This can cause the idle rotation of the knob or damage. 3. Do not overtighten the lock nut. It is possible to tighten the lock nut (hexagon) manually. When tightening further with tools, tighten by approximately 15 to 30. Overtightening may cause breakage.

Note) The dedicated software (LEC-BCW) is required. * When controller equipped type is selected when ordering the LE series, you do not need to order this driver. * When pulse signals are open collector, order the current limiting resistor (LEC-PA-R-m) separately. The driver is sold as single unit after the compatible actuator is set.

Do not mount this kit on other products. Carefully read the procedure manual included with this kit before performing the installation.

Do not use with flammable or highly permeable fluids. Fire, explosion, damage or corrosion can result.

Do not use the product in a place where static electricity is a problem. Otherwise it can cause failure or malfunction of the system. 1 L+ Brown 18 to 30 VDC 2 N.C.

Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. UP button Selects a mode and the display shown at the sub screen, and increases the ON/OFF set values.

Do not apply fluid under leaking conditions. Safety cannot be assured in the case of unexpected malfunction.

Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. 5% of rated flow Hysteresis Setting of hysteresis can prevent chattering. UP button Selects a mode and the display shown at the sub screen, and increases the ON/OFF set values.

Do not use in the atmosphere and environment over the rated specifications. 2. Do not use in the environment of corrosive gas or liquid splash. 3. Do not use in an environment where oil and chemicals are used. Maintenance Caution 1. Perform periodic inspection. 249

Do not apply rotational torque to the cylinder rod. In order to prevent rotational torque from acting upon the cylinder rod, mount it so that the contacting surfaces of the pallet and cylinder are parallel to one another. 4. Do not use oil, etc. on the sliding parts of the piston rod. This can cause trouble with retraction or other malfunctions.