) (3) (4) 1 (1) 2) 01 1 S () 02 2 P () : 08 8 (3) (PD) 1) 1 B (: P ) 3 (: PD ) C 2) 1) 3)12S 0.5 8 0.7 6 (4) 1.0 4 2) 8 4 A 4) Assy 6 - No.ZQ-OM01401-B ZQ000 U A-K15L B-EA M G-3 3-N (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (1) U (6) M 6) (2) M SI (kPa) 6) (:psi) P K1 N.C.
FV4 MV4 TW4 FV6 MV6 TW6 FV8 MV8 TW8 Material Body Poppet Diaphragm Code 316L SS secondary remelt Seat material 316L SS S 316L SS Code Material PCTFE (Standard) Vespel No code Surface finish Surface finish Ra max 10 in. (0.25 m) Standard 7 in. (0.18 m) 5 in. (0.13 m) Code VS M V X Pressure gauge unit 2) Unit psig/bar MPa Code No code MPA Ports Ports 2 ports 3 ports 4 ports Code Gauge port
Mar Nm 1 = M/Ma 1 = 0.1/13 = 0.008 300 Va mm/s 3-2 Load Factor of Dynamic Moment Find the dynamic moment Me (Nm). Examine Mep.
S + Stroke ZZ + Stroke Series CY3R Thread type Bore size (mm) 15 M thread Rc thread S + Stroke 20, 25, 32, 40 NPT thread QW Z + Stroke G thread Features 1 Upgraded version of saving magnetically rodless cylinder! Upgraded version of saving magnetically rodless cylinder!
W : Mass (kg) F : Load (N) FE : Load equivalent to impact (when stopper collides) (N) a : Average speed (mm/s) M : Static moment (Nm) : Collision speed (mm/s) L1 : Distance to the center of load gravity (m) ME : Dynamic moment (Nm) g : Gravitational acceleration (9.8 m/s2) At impact: = 1.4 a 1.4 100 = 1.4 a (mm/s) FE = agW Note 4) ME = FEL1 = 0.05 agWL1 (Nm) 1 3 Note 4) Average load coefficient
valves there is no S option.
pressure center For AC voltage valves there is no S option.
SYJ7140-02 AN110-01 48 Series SYJ7000 How to Order Light/surge voltage suppressor Electrical entry for G, H, L, M, W Electrical entry for D Type of actuation Nil S Z R U Nil S Z Without light/surge voltage suppressor With surge voltage suppresor With light/surge voltage suppressor With surge voltage suppressor (Non-polar type) Without light/surge voltage suppressor With surge voltage suppressor
pressure center For AC voltage valves there is no S option.
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid state auto switches marked are produced upon receipt of order. Other than the applicable auto switches listed in How to Order, the other auto switches can be mounted. For detailed specifications, refer to page 1479.
However, please contact SMC for water-resistant products of 20 and 25. 2 1 m type lead wire is only applicable to D-A93. Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ None N (Example) H7CN Solid state auto switches marked with are produced upon receipt of order.
Please contact SMC for more information. 1674 Cylinder Speed Checker IN574-95/-73 M 3 Measurement Modes Speed (mm/s) Measures the speed of cylinders.
Also, regularly check there is no deterioration due to ozone. 444 Technical Data IZN10 Series Blow Velocity Distribution (Supply Pressure: 0.3 MPa) IZS (1) Energy saving static neutralization nozzle/IZN10-01 (2) High flow rate nozzle/IZN10-02 IZN IZN IZF ZVB IZD IZE IZH 0 0 100 100 200 200 Distance [mm] Distance [mm] 3 [m/s] 14 [m/s] 300 300 2 [m/s] 11 [m/s] 400 400 1 [m/s] 9 [m/s] 500 30
Altitude [m] 1. Max. ambient 2. Cooling capacity temp.
MN Option Nil None M plug connector S With surge voltage suppressor Z With light/surge voltage suppressor Indicator light is not available for grommet type.
Specifications 0.01m (95% filtered particle diameter) Outlet air filtration degree Max. 0.1mg/m (ANR) (0.08ppm) Note 1) Outlet air oil mist concentration (prior to oil saturation 0.01mg/m (ANR) or less (0.008ppm or less) Note 1) With inlet air oil mist concentration of 30mg/m (ANR) (24ppm) Applicable models IDG3V to IDG50V (standard dew point 20C) (4F)) IDG3HV to IDG50HV (standard dew point
The kinetic energy of load can be found using the following formula. 20 10 5 V M M 2 V 2 100 300 1000 2000 500 Ek = Ek: Kinetic energy (J) M: Weight of load (kg) V: Piston speed (m/s) Maximum drive speed (mm/s) Example) Load limit at rod end when air cylinder 63 is actuated with max. actuating speed 500 mm/s. at a maximum drive speed of 500 mm/s.
The kinetic energy of load can be found using the following formula. 20 10 5 V M M 2 V 2 100 300 1000 2000 500 Ek = Ek: Kinetic energy (J) M: Weight of load (kg) V: Piston speed (m/s) Maximum drive speed (mm/s) Example) Load limit at rod end when air cylinder 63 is actuated with max. actuating speed 500 mm/s. at a maximum drive speed of 500 mm/s.