Combination screw M3 Tightening torque 0.5 to 0.6 Nm Combination screw M3 A Conduit terminal View A-A (Internal connection diagram) G + mark mark + 1 2 Series VC A Conduit When used as an IP65 equivalent, use seal (Part no. VCW20-156) to install the wiring conduit. Also, use the tightening torque below for the conduit.

Manifold base recommended dimensions Lead wire Base mounting hole 1 (IN) 2 (OUT) 1 (IN) 9.5 or more Valve mounting pitch 2 (OUT) A A M3 x 0.5 Thread depth 5 2 (OUT) port 1 (IN) port 3 M3 x 0.5 Thread depth 5 Electrical entry can be on the either side, right or left. 2 (OUT) port 3 11 11 40 Sectional view A-A (2:1) 4 4 46 or more RZ12.5 1 (IN) port 510 High Speed 2 Port Valve SX10 Series Control

(ANR) ( 0.8 ppm) Note 3) Note 4) AWM20 to AWM40 Outlet side oil mist concentratio Max. 0.1 mg/m3 (ANR) (Before saturated with 0.001 mg/m3 (ANR) or less 0.008 ppm) Note 3) Note 4) AWD20 to AWD40 AWM20 to AWM40 330 150 820 Rated flow (l/min (ANR)) Note 5) AWD20 to AWD40 180 90 450 25 8 45 Drain capacity (cm3) Polycarbonate Bowl material Semi-standard Standard Bowl guard Relieving type Regulator

Appearance Terminal block For wiring, please refer to P.2-5 10,11Remote control 12,13Operation 14,15Failure L1,L2,L3: Power supply PE: Ground 15 14 13 12 11 10 PE L3 L2 L1 Customer Connection Side Customer Connection Side Terminal connecting screw: M3 Terminal connecting screw: M5 Crimped terminal width: 6.5mm or less Crimped terminal width: 13mm or less Applicable electric wire: 8mm 2

Terminal block For wiring, please refer to P.2-5 10,11Remote control 12,13Operation 14,15Failure R,S,T: Power supply PE: Ground 15 14 13 12 11 10 R S T To the users machine To the users machine Terminal connecting screw: M3 Terminal connecting screw: M5 Crimped terminal width: 6.5mm or less Crimped terminal width: 13mm or less Applicable electric wire: 8mm 2 or more Applicable electric wire

Refer to page 5-11-4.) Not required (Use turbine oil Class 1 lSO VG32, if lubricated.) Free 300/50 VPA342: VP300-27-1A VPA542: VP500-27-1A VPA742: VP700-27-1A Bracket (With screw) Option N.C. N.O. Note) Impact resistance: No malfunction from test using drop impact tester, to axis and right angle directions of main valve, each one time when pilot signal ON and OFF.

D-X 20Data 10-9-11 11 Lever Detection Switch (Proximity Switch) Proximity Switch Specifications/Maker: OMRON Corp. Mounting Position E2E-X1C1 E2E-X2D1-N Model RSH20, 32 RS1H50, 63, 80 Applicable cylinder bore size E2E-X1C1 (For RSH20/32) While holding the lever in the detection range of the switch, screw in the switch gradually until the indicator light (red) turns on.

No.PS-OMU0009-D PRODUCT NAME Digital Pressure Switch MODEL / Series / Product Number ZSE20C(F) ISE20C(H) Table of Contents Safety Instructions 2 Model Indication and How to Order 9 Summary of Product parts 11 Definition and terminology 12 Mounting and Installation 16 Installation 16 Piping 19 Wiring 21 Outline of Settings [Measurement mode] 24 Pressure Setting 25 3 Step Setting Mode 26 Simple

ZX B B A B A B ZR P1 A A ZM 10 9 4 5 ZMA ZQ 3 ZH ZU ZL ZY ZF 11 ZP Section A-A' (Ejector) 12 SP 2 7 ZCUK AMJ 8 AMV AEP HEP Related Equipment 6 1 Section B-B' (Solenoid valve) Component Parts Replacement Parts Description Material Note Description Part no. No. No.

D-X 20Data 10-9-11 11 Lever Detection Switch (Proximity Switch) Proximity Switch Specifications/Maker: OMRON Corp. Mounting Position E2E-X1C1 E2E-X2D1-N Model RSH20, 32 RS1H50, 63, 80 Applicable cylinder bore size E2E-X1C1 (For RSH20/32) While holding the lever in the detection range of the switch, screw in the switch gradually until the indicator light (red) turns on.

Load factor 1 = m3 / m3 max = 7.025 / 22.5 = 0.31 m3 M2: Moment Z M2 max (from 2 of graph MY2H / M2) = 19.5 (Nm) . M2 = m3 x g x Z = 7.025 x 9.8 x 37.8 x 103 = 2.60 (Nm) Load factor 2 = M2 / M2 max = 2.60 / 19.5 = 0.13 m3 M2 5 Series E-MY2 Selection Example cont. X M3: Moment M3 max (from 3 of graph MY2H / M3) = 19.5 (Nm) .

Type AS1200-M3 Direct cylinder elbow type 2 Bore size JIS Symbol Direct cylinder flat elbow type 4 Symbol Bore size Applicable series Control type AS1200-M3 AS1400-M3 M3 M3 x 0.5 Meter-out Meter-in 0 1 AS120-M5 AS120-U10/32 AS220-01 AS220-02 AS320-03 AS420-04 M5 x 0.8 10-32UNF 1/8 1/4 3/8 1/2 M5 U10/32 01 02 03 04 P.15-11-3 Thread type Cylinder side R Tube side Rc Symbol Metric thread (M3

12 1 L/min SI SI ON-OFF ON 0 20 1 atm()[Anr] ripple -13No.PF-OMS0001CN-A 9022545 -14No.PF-OMS0001CN-A 2 0.50.7 Nm M4 (4 ) (71 ) M4 -15No.PF-OMS0001CN-A M3 (2 ) (71 ) 0.50.7 Nm M3 -16No.PF-OMS0001CN-A IN8cm 2F.S.

Description and Functions 9 5-1 LED indication 9 5-2 Terminal board 9 5-3 Address setting 10 5-4 Setting of Hold/Clear 11 6. Wiring 12 6-1 Communication wiring 12 6-2 Terminal resistance 13 6-3 Cable for communication line 13 6-4 Wiring to power supply 13 7. Troubleshooting 14 -1No.EX-OMF0012-B 1.

Standard Strokes Stroke (mm) Bore size (mm) Bore size (mm) Mounting bracket Applicable switch Note 50 100 75 125 150 175 200 250 300 400 500 25 Switch mounting screw (M3 X 0.5 X 8 l ) Square nut 12 V V V V V V D-A7, A8 D-A7lH, A80H D-A73C, A80C D-A79W D-F7lV D-F7, J7 D-J79C D-F7lWV D-F79W, J79W 12 20 BQ-1 20 V V V V V V V V 32 V V V V V V V V V Switch mounting screw (M3 X 0.5 X 10 l )

Moment (Nm) Payload (N) ML1C/M2,M3 How to calculate the load ratio A. Consider q Max. payload, w static moment, e dynamic moment (when stopper collides) when calculating the Max. allowable moment and payload. Evaluate q and w as a (average speed), and e as (collision speed =1.4a).

For details, refer to the pressure gauge guide on page 14-11-1.

B H 10 Y-J010B 15.2 8 21 M4 x 0.7 CP95 SNJ-006B 16 Y-J016B 6 NTJ-006A 16.6 11 21 M5 x 0.8 9.2 8 M6 x 1.0 4 6 5.5 6.4 M3 x 0.5 2.4 SNJ-010B 10 NTJ-010A 12.7 11 M8 x 1.0 4 10 7 8.1 M4 x 0.7 3.2 NDd9 NDH10 R1 NX U1 Part no.

Cool from 30C (303 K) to 20C (293 K). : Clear water Density : 1 x 103 kg/m3 Specific heat C: 4.2 x 103 J/(kgK) Water bath Refer to the information shown below for the typical physical property values by circulating fluid.

Suitable screw torque (Nm) Body size M3 0.07 M5 0.3 1/8 1 1/4 1.5 3/8 4 1/2 10 15-8-6 Flow Control Equipment Precautions Series ASN2 Handling of One-touch Fittings Caution Selection 1. Refer to page 15-1-11 for One-touch Fitting. Warning 1.