Series: 7 (VP700), Pressure Specification: K (High-pressure Type, 1.0 MPa), Voltage: 3 [110 VAC, (115 VAC)], Electrical Entry: D (DIN Terminal w/Connector), Light/Surge Voltage Suppressor: w/o Light/Surge Voltage Suppressor, Manual Override: E (Push-turn Locking Type, Manual), Bracket: B (w/Bracket), Flow Direction: R (Right to Left)
Series: 7 (VP700), Pressure Specification: K (High-pressure Type, 1.0 MPa), Voltage: 3 [110 VAC, (115 VAC)], Electrical Entry: D (DIN Terminal w/Connector), Light/Surge Voltage Suppressor: w/o Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Bracket: B (w/Bracket)
Series: 7 (VP700), Pressure Specification: K (High-pressure Type, 1.0 MPa), Voltage: 3 [110 VAC, (115 VAC)], Electrical Entry: D (DIN Terminal w/Connector), Light/Surge Voltage Suppressor: w/o Light/Surge Voltage Suppressor, Manual Override: E (Push-turn Locking Type, Manual), Bracket: B (w/Bracket)
Series: 5 (VP500), Pressure Specification: K (High-pressure Type, 1.0 MPa), Voltage: 3 [110 VAC, (115 VAC)], Electrical Entry: D (DIN Terminal w/Connector), Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: E (Push-turn Locking Type, Manual), Bracket: B (w/Bracket), Flow Direction: R (Right to Left)
Series: 5 (VP500), Pressure Specification: Standard (0.7 MPa), Voltage: 3 [110 VAC, (115 VAC)], Electrical Entry: D (DIN Terminal w/Connector), Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: E (Push-turn Locking Type, Manual)
Series: 5 (VP500), Pressure Specification: K (High-pressure Type, 1.0 MPa), Voltage: 4 [220 VAC, (230 VAC)], Electrical Entry: Y [DIN Terminal (EN175301-803C) w/Connector], Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type
Series: 7 (VP700), Pressure Specification: K (High-pressure Type, 1.0 MPa), Voltage: 4 [220 VAC, (230 VAC)], Electrical Entry: Y [DIN Terminal (EN175301-803C) w/Connector], Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Bracket: w/o Bracket, Flow Direction: R (Right to Left)
0.10.45/0.65 (at 20 l/min)20Approx. 15Approx. 16Rc 3/4Stainless steel, EPDM, Copper brazing (Heat exchanger), PPS, Silicone, Fluororesin10 to 250.3 to 0.713/14Rc 1/2Stainless steel, EPDM, Copper brazing (Heat exchanger), Silicone, Brass3-phase 200 VAC 50 Hz, 3-phase 200 to 208 VAC 60 Hz Allowable voltage fluctuation ?
(50/60 Hz), 240 VAC (50/60 Hz) 12, 24 VDC?
(50/60 Hz), 240 VAC (50/60 Hz) 12, 24 VDC?
(50/60 Hz), 240 VAC (50/60 Hz) 12, 24 VDC?
(No condensation) Withstand voltage 500 VAC for 1 minute between external terminals and F.E. Insulation resistance 500 VDC, 10 M min. between external terminals and F.E.
(No condensation) Withstand voltage 500 VAC for 1 minute between external terminals and F.E. Insulation resistance 500 VDC, 10 M min. between external terminals and F.E.
(No condensation) Withstand voltage 500 VAC for 1 minute between external terminals and F.E. Insulation resistance 500 VDC, 10 M or more between external terminals and F.E.
(No condensation) Withstand voltage 500 VAC for 1 minute between external terminals and F.E. Insulation resistance 500 VDC, 10 M min. between external terminals and F.E.
General Specifications Table 4-1 EX245 series general specifications Item Specification Rated voltage 24 V DC +20% -15% Supply interruption for no loss of function 1 ms maximum Protection class IP65 (when fully installed or fitted with protective cover) (complies with IEC 60529) Insulation resistance 10 Mohm @ 500 VAC between FE and all accessible terminals to IEC 61131-2.
(No condensation) Withstand voltage 7 1000 VAC, for 1 minute between the terminals and housing Insulation resistance 50 M min.
(No condensation) Withstand voltage 7 1000 VAC, for 1 minute between the terminals and housing Insulation resistance 50 M min.
S Blow air flow adjustment needle valves Completely transparent workpieces detection is not available. *3: The AC power supply cable attached to the product has the configuration applicable to socket of 100 VAC.The cap needs to be changed when the cable is connected to a socket of voltage other than 100 VAC.
S With flow restrictors for additional air flow at two positions *3: The AC power supply cable attached to the product has the configuration applicable to socket of 100 VAC.The cap needs to be changed when the cable is connected to a socket of voltage other than 100 VAC.