M36 x 1.5 21 47 50 64 4 Compact Cylinder/ Double Acting: Double Rod Series CQ2W 180, 200 How to Order CQ2WB 180 180 50 50 D D C C Z76 With Auto Switch CDQ2WB With auto switch (built-in magnet) Number of auto switches 2 pcs. Nil S 1 pc. n "n" pcs.
205 4 3 2 20 Data 10 20 30 40 50 100 200 300 1 1 2 3 4 5 10 20 304050 100 200300400 Eccentric distance l (mm) 10 400 Eccentric distance l (mm) MGTL100 300 200 300 MGTM100 200 P = 0.5 MPa 100 P = 0.5 MPa Load weight m(kg) Larger than 75st Load weight m(kg) 40 50 100 Larger than 50st 50st 25st 30 25, 50st 20 50 40 10 30 5 4 3 2 20 1 10 20 30 40 50 100 200 300 1 2 3 4 5 10 20 304050 100 200
L3: Analogue output: 1 to 5 V or 0 to 10 V Output impedance: 1 k L4: Analogue output: 4 to 20 mA Max. load impedance: 600 Min. load impedance: 50 PNP + Analogue output type PF3A7##H-##-L3/L4#-## Maximum load current: 80 mA Internal voltage drop 1.5 V max.
time . 4-2 4.7 Signal output . 4-2 Chapter 5 Checks, Maintenance and Adjustment . 5-1 5.1 Daily inspection . 5-1 5.2 Regular maintenance . 5-2 5.2.1 Maintenance for water-cooled condenser . 5-2 5.2.2 Auto Drain Maintenance . 5-6 5.3 Adjustment . 5-8 5.3.1 Capacity Control Valve . 5-8 5.3.2 Sight glass (for IDF240D-3-W only) . 5-8 IDF190D/240D Series IDX-OM-Y002 Contents Chapter 6 Troubleshooting
Cover Cushion Valve Fig. (5) How to Adjust the Air cushion 20 - Internal structure and parts description Rotary actuator internal structure Without air cushion Size 30 Size 50 to 100 21 - Component parts No.
-025X11 50 EJ302S-050X11 75 EJ302S-075X11 1 EJ402S-001X11 3 EJ402S-003X11 5 EJ402S-005X11 10 EJ402S-010X11 65 x 500 25 EJ402S-025X11 50 EJ402S-050X11 75 EJ402S-075X11 Note) Seals are not necessary.
-025X11 50 EJ302S-050X11 75 EJ302S-075X11 1 EJ402S-001X11 3 EJ402S-003X11 5 EJ402S-005X11 10 EJ402S-010X11 65 x 500 25 EJ402S-025X11 50 EJ402S-050X11 75 EJ402S-075X11 Note) Seals are not necessary.
Extension locking Retraction locking Retraction locking Variations Bore size (mm) Standard stroke (mm) Locking direction Mounting Series 20 25 30 40 50 75 100 LOCK 32 Extension lock Through hole LOCK 40 RLQ LOCK 50 Retraction lock Both ends tapped 63 Compact Cylinder with Air Cushion and Lock Series RLQ 32, 40, 50, 63 How to Order B 32 50 M F RLQ B 32 50 M F F9BW RDLQ With auto switch Number
Minimum auto switch mounting stroke (mm) Bore size (mm) Auto switch Number of auto switch mounted 20 25 32 40 50 63 80 100 model 1 pc. 5 D-A9(V) D-M9(V) 2 pcs. 10 1 pc. 5 N o t e 2 ) D-M9W(V) D-M9AV 2 pcs 10 1 pc. 5 N o t e 2 ) D-M9A 2 pcs. 10 N o t e 2 ) 1 pc. 5 N o t e 1 ) 5 D-Z7/D-Z80 D-Y59/D-Y7P 2 pcs. 10 1 pc. 5 D-Y69 D-Y7PV 2 pcs. 5 1 pc. 5 N o t e 2 ) D-Y7W(V) D-Y7BA 2 pcs. 10 N o
override Rated voltage Nil Push type 1 2 3 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz B Locking type (Slotted) C Locking type (Manual) 110 to 120 VAC, 50/60 Hz 4 Surge voltage suppressor Option 220 VAC, 50/60 Hz Indicator light 24 VDC 12 VDC 5 6 Light/Surge voltage suppressor E EZ Nil None 7 240 VAC, 50/60 Hz With light/surge voltage suppressor (Type E, T, D, or Y only) 9 Other Z Option S With
03(S)A 5/32" 8.2 AS221F-02-07(S)A 1/4" 11.2 23.4 32.7 (32.8) 19 (19) AS221F-02-09(S)A 5/16" 13.2 23.9 33.2 (33.3) 14.2 19 (20) AS221F-02-11(S)A 3/8" 15.5 26.4 35.7 (35.8) 15.6 20 (21) AS321F-02-07(S)A 1/4" 1/4 19 11.2 16.6 21.8 32.1 36.4 50 48.4 44.5 42.9 13.3 40 (40) AS321F-02-09(S)A 5/16" 13.2 22.7 33 14.2 41 (41) AS321F-02-11(S)A 3/8" 15.5 26.7 37 35.9 15.6 AS321F-03-07(S)A 1/4" 3/8 19
of max. rated flow [ 2.00] 2.00 L/min (4 L type) [ 8.0] 8.0 L/min (16 L type) [ 20.0] 20.0 L/min (40 L type) [ 50] 50 L/min (100 L type) [ 126] 126 L/min (250 L type) [ P_1] Set value (OUT1) [F 1]/[ oUt1] Page 29 5% of max. rated flow [ 0.20] 0.20 L/min (4 L type) [ 0.8] 0.8 L/min (16 L type) [ 2.0] 2.0 L/min (40 L type) [ 5] 5 L/min (100 L type) [ 12] 12 L/min (250 L type) [ H_1] Hysteresis
to 55 (23 to 131) Ambient temperature C (F) 5 to 50 (23 to 122) 5 to 55 (23 to 131) 5 to 50 (23 to 122) Outlet air atmospheric pressure dew point C (F) Standard performance 20 (-4) Inlet air flow rate l/min (ANR) (SCFM) Note 2) 625 (22.0) 62 (2.19) 125 (4.41) 250 (8.82) 375 (13.24) Outlet air flow rate l/min (ANR) (SCFM) 50 (1.8) 100 (3.5) 200 (7.1) 300 (10.6) 500 (1.77) Purge air flow rate
to 50 5 to 55 5 to 50 Outlet air atmospheric pressure dew point C Standard performance 20 Inlet air flow rate l/min (ANR) Note 2) 625 62 125 250 375 Outlet air flow rate l/min (ANR) 50 100 200 300 500 Purge air flow rate l/min (ANR) Note 3) 12 25 50 75 125 Inlet air pressure MPa 0.7 Inlet air temperature C 25 25 25 1l/min (ANR) {inlet air pressure at 0.7MPa} Inlet air saturation temperature
VN Rated voltage 1 2 3 4 5 6 7 8 9 Solenoid valve option Nil Standard 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 48 VAC 50/60 Hz Other (Please contact SMC separately.) LVC Select an option mark in page 17-3-10 by Applicable Fluids Check List for special fluids outside of the standard.
/60Hz) 200 to 230VAC (50/60Hz) 3-phase 200 to 230VAC (50/60Hz) option Analog monitor output Regenerative option PC LEC-MR-RBRS-422 interface When using this software, order USB cable separately.
50 R5 5 100 100 R8 8 * RA 10 * Motor option RB 15 * Controller *Refer to catalog.
3.5 1.5 M 30 41 50 N 51 64 81 Q 24 35 40 U 5 7 7 V 33 45 50 W 34.5 41 AC21 AC31 AC41 * Without relief valve option ** With relief valve option mm AC-A A* 90 117 154 AA** 140 181 238 B 160 220 239 C 73 86 92 E 30 38 F 45.5 58.5 75.5 G 40 55 80 J 26 29.5 37.5 K 5 3.5 1.5 M 30 41 50 N 51 64 81 Q 24 35 40 U 5 7 7 V 33 45 50 W 34.5 41 AC21A AC31A AC41A * Without relief valve option ** With
point oC 10 Amount of cooling water (50/60Hz) Note 2) L/min 100 Cooling tower capacity Note 3) k W(RT ) 38.5 (8.5) Cooling water pressure drop (50/60Hz) MPa 0.05 (excluding automatic fluid filling valve) Fluid port size 1 1/4 union Power supply voltage (frequency) Note 4) Three-phase AC200V (50Hz) / AC200,220V (60Hz) characteristic Electric Power consumption (50/60Hz) Note 5) k W 11.6 Running