32 100 D Standard Type With Auto Switch CDNG L N 32 100 D B53 Number of auto switches With auto switch (with magnet) 2 pcs.

suppressor With light/surge voltage suppressor 19.5 14.5 n-M5 x 0.8 2-4.3 8.5 mounting hole 21.6 17 P E PE 9.5 9.5 43 Max. 10 78 4-Rc 1/8 2-M5 x 0.8 (Pilot EXH) (Pilot EXH) 2-M5x0.8 2-M5 x 0.8 (Pilot EXH) 300 (Lead wire length) 300 (Lead wire length) 76 68.5 2-M5 x 0.8 (Pilot EXH) Stations n: Stations Formula L1 = 16n + 11 L2 = 16n + 22 2 43 54 3 59 70 4 75 86 5 91 102 6 107 118 7 123 134

For IITV00-n Total weight (g) Stations (n) x 100 + 130 (Weight of end block A, B assembly) + Weight (g) of DIN rail Note 2) Specifications other than the following are optional.

25-MLA [ISE35-N-25-M (Switch body only)] Digital pressure switch Note 5) NPN output: Wiring top entry ISE35-R-25-MLA [ISE35-R-25-M (Switch body only)] PNP output: Wiring bottom entry ISE35-N-65-MLA [ISE35-N-65-M (Switch body only)] PNP output: Wiring top entry ISE35-R-65-MLA [ISE35-R-65-M (Switch body only)] Note 1) Assembly of a bracket and set nuts.

S 1 pc n Mounting style n pcs. Auto switch Through-hole (Standard) Front flange style B F Nil Without auto switch (Built-in magnet) Both ends tapped style Rear flange style A G For the applicable auto switch model, refer to the teble below. Auto switches are shipped together, (but not assembled).

1/8 1/4 3/8 1/2 AS2000E AS2000E/3000E/4000E AS3000E/4000E AS4000E With residual pressure release valve Thread type Nil N F Rc NPT G Caution Be sure to read before handling.

Bore size Applicable series 02 03 04 06 10 12 14 20 Note 1) AS800 is available as special.

Conditions: Operating pressure 0.5MPa, Operating oil Turbine oil Class 1 (ISO VG32), Piping length 1m AS420-02, 03, 04 AS500-06 AS2000-01, 02 AS600-10 AS3000-02, 03 AS4000-02, 03, 04 Circuit 4.12-12

1 3 Port Air Operated Valve Series VPA3145/3165/3185 How to Order SA 04 4 5 1 VPA3 VA Thread type SA VPA Air operated valve Nil Rc G NPT NPTF F N T VA 1 Number of pilot VM Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Port size (IN, OUT port) Single Port size Rc

(Normally open) B 4 VP 5 6 24 VDC 12 VDC Thread type VG Rc Nil G F 7 240 VAC, 50/60 Hz 9 Other VP NPT N Option NPTF T Electrical entry S070 G Grommet D DIN terminal Port size VQ 04 06 10 1 2 Rc T Conduit terminal E Grommet terminal 3 4 Rc Rc 1 VKF Light/Surge voltage suppressor VQZ Nil None S With surge voltage suppressor (Only grommet type is only available.)

Thread type 20 30 40 50 Rc NPT G Nil N F Semi-standard specifications Description Flow direction: Right l Left PSI as unit displayed on label Symbol Nil R Z Note) Port size Symbol Body size 20 ) ) Port size 50 ) ) 40 ) ) ) ) 30 ) ) Note) Only for the NPT thread.

load No load Load ratio Load ratio Bore size (mm) Bore size (mm) AS4000-02/03/04 AS3000-02/03 Piping bore Piping bore Cylinder driving speed (mm/s) Cylinder driving speed (mm/s) Circuit diagram No load No load Load ratio Load ratio Speed controller Bore size (mm) Bore size (mm) 10-17-12 Product Profile: Hydraulic Cylinders: Series CH For details, refer to the catalog CAT.

Stations: 04 (4 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj.

Stations: 04 (4 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: Flow Adj.

Stations: 04 (4 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj.

(Normally open) B Electrical entry G Grommet D DIN terminal Thread type Rc Nil G F T Conduit terminal E Grommet terminal NPT N NPTF T Light/Surge voltage suppressor Nil None Port size S With surge voltage suppressor (Only grommet type is only available.) 04 06 10 1 2 3 4 1 Z With light/surge voltage suppressor (Except grommet type) How to Order Pilot Valve Assembly X84 VO307 G 1 SYJ Valve

How to Order 04 VGA342 A Caution Port size Fluid passage Port thread 1 2 04 Rc(PT) A Normally closed (N.C.) qChange of fluid passage (Standard) Rc(PT) 3 4 06 Rc(PT) B Normally open (N.O.) (Option) 10 Rc(PT)1 F G(PF) N NPT T NPTF Dimensions N.C. N.O. Please note that the pressure in the valve should be exhausted when changing the fluid passage.

HEADQUARTERS 3011 N. FRANKLIN ROAD INDIANAPOLIS INDIANA 46226

The tensile strength of the power supply cord is 49 N (5 kgf). If the cord is pulled with a greater force, it could lead to a malfunction. When handling the product, make sure to hold it by its body. 3. Never move the switch assembly or loosen the switch assembly mounting screws.

The tensile strength of the power cord is 49 N, and pulling it with a greater force can cause failure. 3. When handling the product, never move or loosen the switch assembly or the switch assembly mounting screws.