P . 14-20-57 14-20-42 2 Odor Removal Filter Series AMF How to Order AMF150 to AMF850 AMF 250 03 R B Option R IN-OUT reversal direction Body size Bracket Accessory (Option) 150 Standard 1 8 250 Standard 1 4 350 Standard 3 8 450 Standard 1 2 550 Standard 3 4 650 850 B 1 4 B 3 8 04 B 1 2 06 B Nil Nil B Piping port (B dimension) 1 Standard 11 2 Standard 01 B 1 8 02 03 Thread type Nil Rc F G N
Applicable dryer Capacity Model Inlet voltage Outlet voltage A B C D E F Weight (kg) 200, 220 230, 240 VAC (50 Hz) 200 to 260 VAC (60 Hz) 100 VAC (50 Hz) 100 to 110 VAC (60 Hz) Single phase Single turn IDF-TR500-2 IDF1E-10 to 8E-10 IDU3E-10, 4E-10 500 VA 118 140 150 70 112 142 6 IDF-TR500-3, 4 C VOLUTAGE SELECTOR FUSE B OUT PUT IN PUT E D 4-F A Input cord 2 m Transformer part no.
C J G5-S 150 cm3/min or less 200 cm3/min or less 300 cm3/min or less Supply pressure 0.1 MPa Total allowable leakage 800 cm3/min or less 1000 cm3/min or less 1200 cm3/min or less Weight/Standard Type: MQQT Supply pressure 0.3 MPa CV 1500 cm3/min or less 2000 cm3/min or less 3000 cm3/min or less Supply pressure 0.5 MPa (g) Note 1) Use clean, dry air with no freezing.
C J G5-S 100 CV 250 = 0.7 200 MVGQ 0.5 0.1 0.3 150 CC 100 50 RB 0 1,000 2,000 3,000 J Maximum speed Vmax (mm/s) : Cylinder load ratio Vmax: Maximum speed (Refer to page 10-6-5.) D-X 20Data 10-6-19
Note 1) Please consult with SMC if other specifications for surface treatment are required. 0 50 100 150 200 250 300 Speed [mm/s] Relationship between speed and impact acceleration Laser marking Hexagon wrench 8-18-2 8-18-3 3 Series CYV Model Selection 1 Caution on Design (1) The allowable load mass moment differs depending on the workpiece mounting method, cylinder mounting orientation and
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Heat Resistant, Operating Temperature(°C): -10~150, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Without built-in magnet, Port thread
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Heat Resistant, Operating Temperature(°C): -10~150, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Without built-in magnet, Port thread
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Heat Resistant, Operating Temperature(°C): -10~150, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Without built-in magnet, Port thread
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Heat Resistant, Operating Temperature(°C): -10~150, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Without built-in magnet, Port thread
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RND BODY, ACTUATOR, NCJ2 ROUND BODY CYLINDER, GC, 16MM NCJ2 OTHERS (COMBO), .00000 lb
Input/Output (3)IP AddressSI IP Address (3) (1) (2) -66No.EX-OMS0026CN 2Generic Ethernet Module [I/O Configuration][Ethernet][New Module] [Select Module Type][Generic Ethernet Module][Create] -67No.EX-OMS0026CN [Module Properties] (1)Name (2)CommConnection Parameters (3)IP AddressSI IP Address (4)Assembly Instance Description Decimal Common Format Data-INT Data-SINT Input 100 100 Output 150
(Without sensor), Response time: 150 ms or less Accuracy 1.0%F.S. 1.5%F.S. 2.0%F.S.
ms 0.6F.S. 1.0F.S. 1.5F.S. 420 mA() 300 (DC12 V)600 (DC24 V) 50 0.2F.S.() 150 ms 2 1.0F.S. 1.5F.S. 2.0F.S. 0.5F.S. 2 digits 0.5F.S.1 digit 31/2 72(/) OUT1ON()OUT2ON() 2 ()Low5 msLow0.4 V 121 2 3 2barpsimmHginHg kPakgf/cm 2barpsi MPakPakgf/m kPammH2O -31No.PS-OMG0001CN-H PSE3 IP40 050 -1060 () 3585RH() AC1000 V 1 50 M(DC500 V) 0.5%F.S. (25 ) PSE35P4PPSE3T PBTPBT(PSE3)PPE(PSE3T
N2CO2Ar () -4No.PF-OMJ0005CN-I () * UL UL1310 2 UL1585 2 30[Vrms] 42.4[V ]2 UL , (100 20 ) JIS B 8392-1 1.1.21.6.2 -5No.PF-OMJ0005CN-I * 14 FG (49 N () IN () -6No.PF-OMJ0005CN-I * () 6 33 () () 30 m DC(-)() -7No.PF-OMJ0005CN-I * () () CE 0~50 -8No.PF-OMJ0005CN-I * 3 (20 ) LED * OUT * 23% -9No.PF-OMJ0005CN-I 7 PFM (12) 2 (11) 10 0.210(5)L/min 1 25 0.525(12.5)L/min (11) 50 150
Installation distance mm Detection range mm IZD10-110 Sensor head 10 45 20 85 Installation distance 25 100 Detection hole 30 120 40 150 50 180 Installation distance mm Detection range mm IZD10-510 Detection range 25 100 30 120 Detection hole 40 150 50 180 Sensor head 60 205 70 225 75 235 6-3.
Discharge time is the time required to reduce electricity on the static plate (150 mm x 150 mm, static capacity 20 pF) from 1000 V to 100 V. The above shown values are measured using SMC's measurement instruments and conditions, and not the guaranteed values.3. Ionizer Functions -13- 3. Ionizer Functions 3.1 Functions 1.
Discharge time is the time required to reduce electricity on the static plate (150 mm x 150 mm, static capacity 20 pF) from 1000 V to 100 V. The above shown values are measured using SMC's measurement instruments and conditions, and not the guaranteed values.3. Ionizer Functions -13- 3. Ionizer Functions 3.1 Functions 1.
In general, 80 to 100 mesh (150 to 180 m) filters are recommended. When transferring a coagulable liquid, take measures to prevent it from coagulating in the pump. Precautions to observe when transferring slurry Basically, it is not recommended to transfer slurry because this will result in seating failure and wearing of the check valve and accumulation of particles.
Operating fluid Eliminate all solid material larger than 150 m in the fluid to avoid valve failure. Piping Caution 1. Piping to pilot port Condensation may be formed in the piping to the pilot port, due to factors such as its length. The life of the valve will be shortened if condensed moisture enters the pilot port.
Table 3-1 Quality standard for fresh water (tap water) Item Standard value pH25oC 6.5 to 8.2 Electric conductivity (25oC) (S/cm) 100 to 800 Chloride ion (mgCl-/L) 200 or less 2-/L) 200 or less Sulphate ion (mgSO4 Acid consumption (pH4.8) (mgCaCO3/L) 100 or less Total hardness (mgCaCO3/L) 200 or less Calcium hardness (mgCaCO3/L) 150 or less Quality item Ion silica (mgSiO2/L) 50 or less Iron