Search Results "LEJS63S3A-1000-R5A1"

125, 140 M30 x 1.5 54000 36000 3 55000 160 M36 x 1.5 71000 55000 Option/Thread nominal size JA20-8-100 JA25-10-150 JA32-10-100 JA40-12-125 JA40-12-150 JA40-12-175 JA50-16-150 JA63-16-200 JA80-20-250 20 M8 x 1 1100 1100 1000 0.5 Series JA 25 M10 x 1.5 2500 2500 2000 0.5 Precautions 32 M10 x 1 2500 2500 2000 0.5 30, 40 M12 x 1.25 4400 4400 4400 0.75 Be sure to read before handling.

V = 2gH/1000 x 60 Obtain the total amount of the workpiece. Total weight m = 10 x 0.1 (kg) = 1 (kg) Obtain the intersection of the transfer speed V and the total weight of workpiece m.

Lateral load Operating pressure: 1 MPa 1000 200 300 500 Stroke Eccentric distance 100 100 Load weight (kg) 10 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 63 Allowable lateral load (N) 50 40 63 1 32 25 20 50 40 10 32 0.1 25 10 100 200 300 500 1000 Maximum piston

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com V (mm/s) = Auto switch operating range (mm) Load operating time (ms) 1000 3. Keep wiring as short as possible.

Standard equipped with shock absorber -X 75 100 125 150 200 250 300 20 25 32 40 50 63 80 100 20 25 32 40 50 20Series MGC P . 8-21-6 Data Series MGG V V V V V V V V V V V V V V Guide Cylinder Guide Table Cylinder with Turntable Series MGC Long stroke Bore size (mm) Standard stroke (mm) Compact type of series MGG Lightweight, space-saving 250 300 350 400 450 500 600 700 800 900 1000 1100 1200

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Enclosure: IP65

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, HIGH RIGIDITY RODLESS SLIDE, S, ACTUATOR, ELECTRIC ACTUATOR, MC, 40MM LE ELECTRIC ACTUATOR, 30.64425 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, HIGH RIGIDITY RODLESS SLIDE, S, ACTUATOR, ELECTRIC ACTUATOR, MC, 40MM LE ELECTRIC ACTUATOR

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, HIGH RIGIDITY RODLESS SLIDE, S, ACTUATOR, ELECTRIC ACTUATOR, MC, 40MM LE ELECTRIC ACTUATOR, 17.41651 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, HIGH RIGIDITY RODLESS SLIDE, S, ACTUATOR, ELECTRIC ACTUATOR, MC, 40MM LE ELECTRIC ACTUATOR, 22.35854 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, HIGH RIGIDITY RODLESS SLIDE, S, ACTUATOR, ELECTRIC ACTUATOR, MC, 40MM LE ELECTRIC ACTUATOR, 20.72345 lb

Generates error per channel when the output value exceeds the upper limit. 4 Enable Generates an error. 3 Val: -32766 to 32767 Scale upper limit setting 1 (UpLm/Scl) Does not generate an error. 3 Val: -32766 to 32767 Disable Val: 1000 Generates error per channel when the output value exceeds the set value.

(no condensation) Environment Withstand voltage 1000 VAC, 1 min. between terminals and case Insulation resistance 50 M min.

(No condensation) Withstand voltage 7 1000 VAC, for 1 minute between the terminals and housing Insulation resistance 50 M min.

Viscosities up to 1000 mPa s can be used. Ratio of discharge amount to fresh water(%) 100 90 80 70 60 50 40 30 20 10 0 1000 100 10 1 Viscosity(mPa s) mPas Silicone oil Lubricant Vegetable oil Water 1 60 to 80 340 950 1500 3150 980 0 Viscosity (mPa s) 0 100 1000 10 Medical barium Cutting oil Tomato juice Honey Woosterource 4500 45 150 2000 to 3000 2650 8 - 8.

No, Yes MENU 2 Signal Direction Open, Close 3 Position Limit Low 0.0% [0..100%] METHOD 4 Position Limit High 100.0 % [0..100%] 5 Travel Rate Open 0.0 %/s [0..1000%/s] Editable variable 6 Travel Rate Close 0.0 %/s [0..1000%/s] 7 Low Cut-off 2.0 % [0..100%] Read-only variable 8 High Cut-off 100.0 % [0..100%] 9 Split Range Low 0.0 % [0..100%] in ND9000HT only Split Range High 100.0 % [0..100%

Heat resistant lead wire (between sensor unit and amplifier unit) 3.4 Lead wire Oilproof heavy-duty vinyl code (amplifier unit grommet) 3.4, 0.2 mm2, 3-wire, 3000 mm Impact resistance Sensor unit: 1000 m/s2, Amplifier unit: 300 m/s2 Insulation resistance 50 M or more under the test voltage 500 VDC (between lead wire and case) Withstand voltage 1000 VAC, 1 min.

The maximum piston speed is: Auto switch operating range [mm] V [mm/s] = 1000 Load operating time [ms] (2) Take precautions when multiple actuators are used close together. When using two or more actuators with auto switches in close proximity to each other, maintain a minimum separation distance of at least 40 mm.

The maximum piston speed is: V [mm/s] = Operating range of product [mm] x 1000 Operating time of load [ms] Take precautions when multiple actuators are used close together. When using two or more actuators with auto switches in close proximity to each other, maintain a minimum separation distance of at least 40 mm.