SMC Corporation of America
Elite Part Number Search
Search Results "LEFS32LEB-500"

For further details on solenoid valves, refer to the SMC solenoid valve catalog "SYJ 300, 500, 700" (E143-B). Note 3) Solenoid valves are shipped facing downward (flange side), but can be rotated to face upward.

Vp-p, Pulse width: 1 m S, Start up: 1 nS Withstand voltage 1000 VAC(50/60 Hz) for 1 min. between lead wires and body Insulation resistance 2 M (at 500 VDC) between lead wires and body Vibration resistance 2 hrs. each in X, Y, Z directions at smaller of 10 to 500 Hz with amplitude 1.5 mm, or acceleration 10 G Impact resistance 100 G in X, Y, Z directions, 3 times each Note) Not available

For example, SMC's S-phase LX actuator motors are divided into 500 steps. Thus, one pulse in full step mode equals (360'+ 500=) 0.72'of shaft rotation. See also Stepping. Full Step A half step is the unit of incremental motion that is 1/2 the basic motion step. SMC's 2-phase LX actuator motors are divided into 200 steps. Each pulse in half step mode equals 0.9'of rotation.

N213 aOSilrtr 3 way.3 port sotenoid vatve NVZseies Rubber Seal Model 100/300/500 Low Power Consumption 1.8 WDC Compact Size, Large Flow Capacity Cv 0.05 0.5 High Speed Response Time -15 mSec (NVZ 100) Built-in One-Touch Fitting Manifolds Avaihbb Individual or Manifold Mounting Variat ions of C L Kl tmrn"..

M12 Connector Cable (4 Pins) Made by OMRON Part number Cable length [mm] ZS-37-L 300 ZS-37-M 500 ZS-37-N 1000 ZS-37-P 2000 ZS-37-C 5000 Part number Cable length [mm] Changing the entry direction After separating the terminal block and housing, the cord entry can be changed by attaching the housing in the opposite direction 180.

rate: 50% Stroke 300 mm 6 10 16 20 25 32 40 Average speed (mm/s) Series 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation SYJ3140-M5 Cylinder is in extending.

cm3/min or less (Air) Exterior leakage 0.1 cm3/min or less (With water pressure), 1 cm3/min or less (Air) Mounting orientation Upward coil Vibration/Impact Note 2) 30 m/s2 / 90 m/s2 P7, P10 (Quick fastener) C4, C6, C8, C10 (One-touch fitting) Port size Orifice diameter 1, 3, 4.5, 6 Rated voltage 24 VDC, 12 VDC 10% of rated voltage Allowable voltage fluctuation Coil insulation type Class B 500

-01-15CN1 pc. 30 3 m ZS-10-5 A-501 pc. 50 5 m 780 Compact Pressure Switch Series ZSE2/ISE2 Specifications ZSE2 For vacuum 0 to 101 kPa ISE2L For low pressure 0 to 100 kPa ISE2 For positive pressure 0 to 1 MPa Model Rated pressure range/Set pressure range Proof pressure Fluid Power supply voltage Current consumption Response time Repeatability Air/Non-corrosive, non-flammable gas 1.5 MPa 500

Cylinder Speed Chart Bore size Series CJ2 Pressure 0.5 MPa Load factor 50% Stroke 60 mm Series CM2 Pressure 0.5 MPa Load factor 50% Stroke 300 mm Series MB Pressure 0.5 MPa Load factor 50% Stroke 500 mm 6 10 16 20 25 32 40 40 50 63 80 100 Series Average speed (mm/s) 800 700 600 500 400 300 200 100 0 It is when the cylinder is extending that is meter-out controlled by speed controller which

to 1 MPa 0.1 to 0 MPa 1.5 MPa Air/Non-corrosive, non-flammable gas 12 to 24 VDC 10%, Ripple (P-P)10% or less (With power supply polarity protection) 1 output: 17 mA or less at 24 VDC, 2 output: 25 mA or less at 24 VDC 5 ms or less 1% F .S. or less IP40 Operating: 0 to 60C, Stored: 10 to 60C (With no condensation and no freezing) Operating/Stored: 35 to 85%RH (With no condensation) 10 to 500

Pulling Strength Model Without inner sleeve With inner sleeve TU1208 140 N 500 N TU1065 140 N 450 N TU0805 110 N 250 N TU0604 80 N 180 N TU0425 50 N 160 N Reference: Thrust Force Occurring at 0.8 MPa Model Load TU0425 10 N TU0604 25 N TU0805 40 N TU1065 65 N TU1208 90 N Note 3) Please consult with SMC regarding applicable tube separately.

Bore size Series MB, CA2 Pressure 0.5 MPa Load factor 50% Stroke 500 mm Series CM2 Pressure 0.5 MPa Load factor 50% Stroke 300 mm Series CJ2 Pressure 0.5 MPa Load factor 50% Stroke 60 mm Average speed (mm/s) Series 6 10 16 20 25 32 40 40 50 63 80 100 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation VQ1101 Port size: 6 one-touch fitting 800 700 600 500

Available response time settings 20 ms, 100 ms, 500 ms, 1000 ms, 2000 ms This function averages pressure values measured during the response time set by the user and then compares the average pressure value with the pressure set point value to output the result on the switch.

SDN1: 32 points SDN2: 16 points Number of outputs 32 points Connection load Series SJ2000/3000 manifold valves Output when communication error occurs Hold/Clear (Switch setting) Enclosure IP20 10 to 50C Operating temperature range Operating humidity range 35 to 85%RH (With no condensation) Withstand voltage 500 VAC for 1 min. between external terminals and FG EX 10 M or more (500 VDC) between

MRQ Mass Rotating angle Size Basic mass (g) Flange (g) Add'l stroke mass (g/mm) 80 to 100 1400 500 4 32 170 to 190 1500 80 to 100 2100 40 500 5 2300 170 to 190 Calculation: (Example) MRQBS32-50CA Basic mass 1400 g 4 x 50 = 200 g Stroke additional mass Total 1600 g For the mass of auto switch alone, refer to pages 767 to 809.

VDC Mega) Insulation resistance 10 to 500 Hz 1.5 mm amplitude or 98 m/s2 acceleration, X, Y, Z directions for 2 hours each (De-energized) Vibration resistance 980 m/s2 in X, Y, Z directions, 3 times each (De-energized) Impact resistance 2% F.S. or less (Based on 25C) Temperature characteristics Halogen-free heavy-duty cable, 3 cores, 2.7, 3 m, Conductor area: 0.15 mm2, Insulator O.D.: 0.8

-X 685 CE2 Series Cylinder Specifications Bore size (mm) 40 50 63 80 100 Fluid Air (Non-lube) Proof pressure Drive 1.5 MPa Brake 0.75 MPa Maximum operating pressure Drive 1 MPa Brake 0.5 MPa Minimum operating pressure Drive 0.1 MPa Brake 0.3 MPa Piston speed 50 to 500 mm/s* Ambient temperature 00 to 60C (No freezing) Brake system Spring and pneumatic lock type Sensor cord length 7-500 mm

Flashing: Flashing cycle of 500 ms Not automatically recovered. Turn power off and then on again. 1.6 Over current 500 ms 500 ms 0 1.0 5.0 1.3 1.2 Input signal Voltage [V] Flashing: Two ashing cycles of 250 ms at two-second intervals Error automatically resets when the supply ow rate is recovered (LED goes off).

Heat exchanger Radiating method W Water-cooled Temperature controller 007 B HED C 2 Cooling capacity Communication 003 005 007 A B RS-485 RS-232C 300 W 500 W 750 W Temperature controller Power supply 2 Single-phase 180 to 242 VAC 50/60 Hz 176

03, 04 100 200 01, 23 100 0 0 5 10 0 0 5 10 Number of needle rotations Number of needle rotations AS4201F, AS4211F AS4301F, AS4311F AS3201F, AS3211F AS3301F, AS3311F 10, 11, 12 12, 13, 16 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 1500 1000 08, 09 10, 11 Flow rate L/min (ANR) Flow rate L/min (ANR) 06, 07 1000 500 500 0 0 5 10 0 0 5 10 Number of needle rotations Number of needle rotations