Rated Flow Range: 0.01 to 1 L/min, Flow Adjustment Valve: None (Straight), Port Size: ø4, Output Specification: Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V, Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: Bracket, w/o Flow Adjustment Valve, Calibration Certificate: Calibration Certificate, Made to Order: -
Rated Flow Range: 0.02 to 2 L/min, Flow Adjustment Valve: None (Straight), Port Size: ø4, Output Specification: Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V, Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: Bracket, w/o Flow Adjustment Valve, Calibration Certificate: Calibration Certificate, Made to Order: -
Rated Flow Range: 0.05 to 5 L/min, Flow Adjustment Valve: None (Straight), Port Size: ø4, Output Specification: Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V, Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: Bracket, w/o Flow Adjustment Valve, Calibration Certificate: Calibration Certificate, Made to Order: -
Rated Flow Range: 0.5 to 50 L/min, Flow Adjustment Valve: None (Straight), Port Size: 1/4, Output Specification: Out 1: PNP; Out 2: PNP, Lead Wire: Lead Wire w/Connector + Rubber Cover for Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: Bracket, w/o Flow Adjustment Valve, Calibration Certificate: Calibration Certificate, Made to Order: -
Rated Flow Range: 0.02 to 2 L/min, Flow Adjustment Valve: None (Straight), Port Size: NPT1/8, Output Specification: Out 1: NPN; Out 2: Analog 4 to 20 mA, Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: Bracket, w/o Flow Adjustment Valve, Calibration Certificate: Calibration Certificate, Made to Order: -
Rated Flow Range: 2 to 200 L/min, Flow Adjustment Valve: None (Straight), Port Size: Rc1/4, Output Specification: Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V, Lead Wire: Lead Wire w/Connector + Rubber Cover for Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: Bracket, w/o Flow Adjustment Valve, Calibration Certificate: Calibration Certificate,
Rated Flow Range: 0.1 to 10 L/min, Flow Adjustment Valve: None (Straight), Port Size: ø6, Output Specification: Out 1: IO-Link or NPN/PNP, Lead Wire: w/M12 Conversion Lead Wire and Connector, 0.1m, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: Bracket, w/o Flow Adjustment Valve, Calibration Certificate: Calibration Certificate, Made to Order: -
Rated Flow Range: 1 to 100 L/min, Flow Adjustment Valve: None (Straight), Port Size: NPT1/4, Output Specification: Out 1: PNP; Out 2: Analog 4 to 20 mA, Lead Wire: Lead Wire w/Connector + Rubber Cover for Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: Bracket, w/o Flow Adjustment Valve, Calibration Certificate: Calibration Certificate, Made to Order:
Rated Flow Range: 2 to 200 L/min, Flow Adjustment Valve: None (Straight), Port Size: NPT1/4, Output Specification: Out 1: PNP; Out 2: Analog 4 to 20 mA, Lead Wire: Lead Wire w/Connector + Rubber Cover for Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: Bracket, w/o Flow Adjustment Valve, Calibration Certificate: Calibration Certificate, Made to Order:
Rated Flow Range: 0.01 to 1 L/min, Flow Adjustment Valve: None (Straight), Port Size: NPT1/8, Output Specification: Out 1: PNP; Out 2: Analog 4 to 20 mA, Lead Wire: Lead Wire w/Connector + Rubber Cover for Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: Bracket, w/o Flow Adjustment Valve, Calibration Certificate: Calibration Certificate, Made to Order:
Size: 16, Motor Mounting Position: Right Side Parallel, Motor Type: Servo Motor, 24 VDC, Lead Screw: LEY16: 2.5mm; LEY25: 3mm; LEY32/40: 4mm, Stroke: 30mm, Motor Option: w/Motor Cover, Rod End Thread: Female Rod End, Mounting: Ends Tapped (Standard), Actuator Cable Type: Robotic Cable, Flexible Cable, Cable Length: 10m, Controller/Driver Type: -, I/O Cable Length: -, Protocol: -, Suffix:
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
Rated Flow Range: 05 (0.05 to 5 L/min), Flow Adjustment Valve: None (Straight), Port Size: 01 (Rc1/8), Output Specification: L3 (Out 1: IO-Link or NPN/PNP, Out 2: Analog 1-5V), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve), Calibration Certificate: A (Calibration
Rated Flow Range: 21 (2 to 200 L/min), Flow Adjustment Valve: None (Straight), Port Size: 02 (Rc1/4), Output Specification: A (Out 1: NPN; Out 2: NPN), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve), Calibration Certificate: A (Calibration Certificate), Made
Rated Flow Range: 10 (0.1 to 10 L/min), Flow Adjustment Valve: None (Straight), Port Size: 01 (Rc1/8), Output Specification: L3 (Out 1: IO-Link or NPN/PNP, Out 2: Analog 1-5V), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve), Calibration Certificate: A (Calibration
Rated Flow Range: 50 (0.5 to 50 L/min), Flow Adjustment Valve: None (Straight), Port Size: N7 (1/4), Output Specification: L2 (Out 1: IO-Link or NPN/PNP, Out 2: NPN, PNP, or Input), Lead Wire: N (w/o Lead Wire w/Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve), Calibration Certificate: A (Calibration Certificate),
Rated Flow Range: 50 (0.5 to 50 L/min), Flow Adjustment Valve: None (Straight), Port Size: N7 (1/4), Output Specification: L2 (Out 1: IO-Link or NPN/PNP, Out 2: NPN, PNP, or Input), Lead Wire: Q (w/M12 Conversion Lead Wire and Connector, 0.1m), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve), Calibration Certificate: A (Calibration
Rated Flow Range: 25 (0.3 to 25 L/min), Flow Adjustment Valve: None (Straight), Port Size: N7 (1/4), Output Specification: L (Out 1: IO-Link or NPN/PNP), Lead Wire: Q (w/M12 Conversion Lead Wire and Connector, 0.1m), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve), Calibration Certificate: A (Calibration Certificate), Made to
Series PF3W digital flow switch is perfect for applications requiring a constantly monitored flow of cooling or cleaning water. The PF3W series has been improved both in design and operating performance over the PF2W flow switch. Depending on the selected model, the PF3W is up to 40% smaller in volume, offering improved piping space and flexibility. Designed to work with fluids up to 90ºC