Applicable tubing O.D. d Weight (g) D1 39.2 M1 L3 12.9 M2 M1 12.9 L2 14.3 L4 12.9 L1 5.2 D2 39.2 L3 23.5 Weight (g) D1 10.0 L2 13.7 L1 5.2 Model Tubing O.D. d AQ240F-04-00 Model Tubing O.D. d AQ240F-04-04 6 4 9.3 5 4 9.3 AQ240F-06-00 AQ240F-06-06 13.7 13.7 15.4 6.2 13.7 26.7 40.7 8 10.0 14.7 6 11.6 6 6 11.6 6.2 40.7 AQ340F-06-00 AQ340F-06-06 13.7 19.5 13.7 13.7 6.3 44.8 31.7 13 19.6 11.8
Ambient and fluid temperature Max. operating frequency VFN VT325-D 5 Hz Response time (1) 30 ms or less (at the pressure of 0.5 MPa) Not required (Use turbine oil Class 1 ISO VG32, if lubricated.) Lubrication Manual override Shock/Vibration resistance (2) Enclosure Non-locking push type 150/50 m/s2 Dustproof Note 1) Based on dynamic performance test, JIS B 8374-1981.
Note Manifold block assembly C6: A, B port with One-touch fitting for 6 C8: A, B port with One-touch fitting for 8 C6 C8 VQ7 VZ5000-50A-1q (a) Bolt (Both sides) For D side, With D-sub connector and P/R port with One-touch fitting for 10 For U side, With D-sub connector and P/R port with One-touch fitting for 10 SUP/EXH block assembly VZ5000-51A-1D w EVS D side SUP/EXH block assembly End block
Fieldbus interface connector layout BUS OUT/Port2: M12 4-pin socket, D-coded (SPEEDCON) No. Designation Description 1 TD+ Transmit Data + 2 RD+ Receive Data + 3 TDTransmit Data 4 RDReceive Data BUS IN/Port1: M12 4-pin socket, D-coded (SPEEDCON) No.
Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: 03-5207-8249 Fax: 03-5298-5362 https://www.smcworld.com 2019 SMC Corporation All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 1st printing AA printing AA 0AA Printed in Japan. D-G
Vacuum Filter AFJ20 to AFJ40 Symbol Vacuum lter SP AFJ40 AFJ30 AFJ20 How to Order ZCUK AMJ AFJ 30 q 03 e 80 B T Option/Nominal ltration rating/Type/Semi-standard: Select one of each for a to f. Semi-standard: When more than one specification is required, indicate in alphanumeric order.
H (Conduit terminal: T) I (DIN terminal: D) Main port 1(A), 2(B) A B C D E F G H I J K L M N P Q R S T U Model VNA2-10A VNA2-15A VNA3-20A VNA4-25A 3 8 1 2 3 4 63 144.5 55 125.5 52 42 26 29 4.5 14 24.3 72.5 2.3 80.5 25 75 34 80 84.5 124 135.5 151.5 137 153 156 172 60.5 73 1 80 90 62 72 50 60 31 36 35 40 5.5 6.5 17.5 20 28.3 33.3 84 100 2.3 2.3 92 108 30 35 84 90 43 49 89 95 93.5 99.5 Port
D-DN This catalog is printed on recycled paper with concern for the global environment.
H (Conduit terminal: T) VXA I (DIN terminal: D) VN Main port Rc A H I J K L M R B F G N S C P T D Q U E Model LVC VNA2-10A VNA2-15A VNA3-20A VNA4-25A 3 8 1 2 3 4 63 52 2.3 42 26 25 28 4.5 34 14 72.5 80.5 74.5 79.5 82.5 124 125.5 142.5 24.3 55 LVA 60.5 73 1 80 90 84 100 92 108 62 72 2.3 2.3 50 60 31 36 30 35 35 40 5.5 6.5 43 49 17.5 20 83.5 89.5 88.5 94.5 91.5 97.5 135.5 151.5 137 153 154
HRR Series 3.1 Precautions wiring communication 3-1 HRX-OM-W004 Chapter 3 Serial communication 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers.
Vacuum pressure kPa Vacuum pressure kPa Vacuum pressure ZX 60 60 60 Air consumption 50 50 50 ZR 40 40 40 ZM 30 30 30 Suction flow rate 20 20 20 ZMA Suction flow rate 10 10 10 ZQ Flow characteristics are expressed in ejector vacuum pressure and suction flow.
4000 Flow rate Q [L/min] How to read the graph The sonic range pressure to generate a flow rate of 4000 L/min (ANR) is P1 0.4 MPa for the VXB215A D(H).
Indicator 45 22.5 27 1/8 Pilot port 5 17 D E OUT IN E C B 2 x P Port size A A Dimensions [mm] Model Port size P A B C D E VXB215A D 3/8 23 55 99.8 88.3 11.5 VXB215B E 1/2 27 65 106.8 90.8 13.5 VXB215C F 3/4 32 75 111.5 93.2 16 6 VXB Series For Steam Replacement Parts How to order the maintenance kit Maintenance Kit Insulated Adapter (for Individual Parts) VXB021-20-1A (1 set) VXB215 KT *
C D E F G H J K L AS100P-04-04 AS200P-04-04 AS200P-06-06 AS250P-06-06 AS300P-08-08 AS300P-10-10 23.9 31.4 31.3 33.6 37 37.5 41.7 51.4 52.3 54.6 60.5 63.5 26.7 36.4 36.3 38.6 42 42.5 38.9 46.4 47.3 49.6 55.5 58.5 26 30 30 32 36 39 9.3 9.3 11.6 12.8 15.2 18.5 17 17.1 18 18 19 22 4 4 6 6 8 10 4 4 6 6 8 10 10 13.6 13.6 17 22 22 12.7 12.7 13.5 16.8 18.5 21 17.4 18.9 19.9 24.1 27 30.5 22.4 25.7
A 13 15 22 06 08 10 340 400 460 580 640 820 1120 1300 1600 1900 2320 2500 End bracket/IZS40-BE 35 22 4.5 30 18 2 x 5.4 105 33 L 33 Intermediate bracket/IZS40-BM 55 35 22 4.5 36 30 18 2 x 5.4 A 105 33 A A-A section 431 IZS40/41/42 Series Dimensions Ionizer/IZS41, 42 30 44 304 6.8 30 85 9 60 50 A 60 x (n-1) L n (Number of emitter cartridges), L Dimension L (mm) IZS4-340 IZS4-400 IZS4-460 IZS4
D OUT OUT IN E 2 x A (Port size) F SMC J C H 4 x K Bracket mounting thread A C D E F G H J K Model AF30-02 to 03-X2230 AF40-02 to 04-X2230 AF40-06-X2230 AF50-06 to 10-X2230 AF60-10-X2230 57 118 Rc 1/4, 3/8 Rc 1/4, 3/8, 1/2 Rc 3/4 Rc 3/4, 1 Rc 1 M4 x 0.7 x 0.5 M5 x 0.8 M5 x 0.8 M6 x 1 M6 x 1 44 35 53 14 53 258 245 169 165 78 73 60 60 63 59 47 47 73 73 95 90 70 70 24 24 20 18 95 90 75 70 1056
PA03 02: LEC-MR-RB-032 03: LEC-MR-RB-12 Set this parameter to enable the absolute position detection system. For details, refer to "LECSN-T Operation Manual, Chapter 12.
series 02 03 04 06 10 12 14 20 Caution L (2) Note 1) AS800 is available as special.
Note 3) Station numbers are started from D side although connector is mounted on D or U Side. Note 1) Maximum number is 8 stations. Note 2) It is used as +COM and -COM.
03 03 03 3/8 04 04 04 04 1/2 4 + Nil Nil Nil Nil Without mounting option a Mounting B B B B With bracket H H H H With hexagon panel nut (for panel mount) + Pressure gauge Nil Nil Nil Nil Without pressure gauge Option Note1) G G G G Round type pressure gauge 5 EA EA EA EA NPN open collector 1 output b With digital pressure switch EB EB EB EB PNP open collector 1 output EC EC EC EC NPN open