Body Size: 20, Backflow: K (w/Backflow Function), Thread: F (G), IN Port Size: 01 (1/8), OUT Port Size: 01 (1/8), Options: G (Round Pressure Gauge w/Limit Indicator), Set Pressure: 0.05 TO 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Knob: Downward, Pressure Unit: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa
Body Size: 20, Backflow: K (w/Backflow Function), Thread: Rc, IN Port Size: 01 (1/8), OUT Port Size: 01 (1/8), Options: BG (w/Bracket + Round Pressure Gauge w/Limit Indicator), Set Pressure: 0.05 TO 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Knob: Downward, Pressure Unit: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa
Body Size: 20, Backflow: K (w/Backflow Function), Thread: N (NPT), IN Port Size: 01 (1/8), OUT Port Size: 01 (1/8), Options: E (Square Embedded Type Pressure Gauge, w/Limit Indicator), Set Pressure: 1 (0.02 to 0.2 MPa Setting, Exhaust Mechanism: Relieving Type, Knob: Downward, Pressure Unit: Z (Unit on Product Label: psi, Pressure Gauge: MPa/psi Dual Scale)
Panel mount adapter ZS-46-B Panel mount adapter + Front protection cover ZS-46-D Lead wire with connector ZS-46-3L 3-core, 2 m, Non-waterproof (Without waterproof cover) Front protection cover ZS-27-01 D Panel mount adapter + Front protection cover ZS-46-D R1/8 Piping adapter ZS-46-N1 NPT1/8 Piping adapter ZS-46-N2 9
Clean One-touch Fittings Series KP How to Order KP H 06 KP P 08 01 Applicable fitting size Port size/Applicable tubing O.D.
How to Order VP 3 4 2 5 G 1 01 A Body ported Series 3 5 7 Pilot type VP300 VP500 VP700 Thread type Bracket Nil R Internal pilot External pilot Nil F N T Rc G NPT NPTF Nil F Without bracket With bracket Pressure specification Nil K Standard (0.7 MPa) High-pressure type (1.0 MPa) Coil specification Nil T Standard Rated voltage With power saving circuit (DC only) Type of actuation A B N.C.
Nil K Standard type (0.7 MPa) High-pressure type (1 MPa) Thread type Nil F N T Rc G NPT NPTF Semi-standard Rated voltage Port size Nil 01 02 1 2 3 4 5 6 7 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz 24 VDC 12 VDC 240 VAC, 50/60 Hz 1/8 (6A) Without port (For manifold) 1/4 (8A) Light/Surge voltage suppressor Nil With surge voltage suppressor None With surge voltage
R1/8 Piping adapter ZS-46-N1 A2 Bracket B (Horizontal mounting) u Option 3 Symbol Operation manual1 Calibration certicate1 Nil Y K T NPT1/8 N01 NPT1/8 Piping adapter ZS-46-N2 1 All texts are in both English and Japanese.
Controller Mounting: S (Screw Mounting), Cable Length: 1 (1 m), Inlet Port Silencer: B (ANB1-01, 55 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603), Exhaust Check Valve: K (AKH06-00, for 6mm tubing), Exhaust Solenoid Valve: V (V124-5LU-M5)
Controller Mounting: D (DIN Rail Mouting), Cable Length: 1 (1 m), Inlet Port Silencer: A (AN10-01, 62 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603), Exhaust Check Valve: K (AKH06-00, for 6mm tubing), Exhaust Solenoid Valve: V (V124-5LU-M5)
Controller Mounting: D (DIN Rail Mouting), Cable Length: 1 (1 m), Inlet Port Silencer: B (ANB1-01, 55 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603), Exhaust Check Valve: K (AKH06-00, for 6mm tubing), Exhaust Solenoid Valve: V (V124-5LU-M5)
Controller Mounting: S (Screw Mounting), Cable Length: 1 (1 m), Inlet Port Silencer: A (AN10-01, 62 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603), Exhaust Check Valve: K (AKH06-00, for 6mm tubing)
Body Ported RoHS How to Order Valve VF 3 1 3 0 5 G 1 01 Body ported Series 1 3 5 Bracket VF1000 VF3000 VF5000 Type of actuation Nil F Without bracket With bracket Thread type 1 2 3 4 5 2-position single 2-position double 3-position closed center 3-position exhaust center 3-position pressure center Rc G NPT NPTF Nil F N T VF1000/3000 Single type (The bracket cannot be connected after delivered
k=AW-B" target="_blank">here.
1) B Note 2) K Note 3) N None DIN rail length specified Back pressure check valve Special wiring specifications (Except double wiring) With name plate (Side ported only) Manifold mounting D E DIN rail mounting Direct mounting Note 1) Specify DIN rail length with D at the end.
Note 4) Specify -K for wiring specification for cases below. All single wiring Single and double mixed wiring When there are stations which do not require wiring (e.g. single SUP spacer), specify the wiring specification in the manifold specification so that the number of the solenoids is 16 maximum.
Flow Characteristics Flow characteristics Port size 1 4/2 (P A/B) 4/2 5/3 (A/B R) Manifold C [dm3/(sbar)] b Cv C [dm3/(sbar)] b Cv 1(P), 5/3(R) Port 2(B), 4(A) Port Type SS5YJ7-21P-01 1/4 1/4 1/4 2.1 1.4 1.8 0.36 0.32 0.37 0.55 0.36 0.50 2.3 2.1 2.1 0.26 0.24 0.20 0.54 0.50 0.50 1/8 C6 C8 Body ported Type SS5YJ7-21P-C6 SYJ723 for internal pilot Type SS5YJ7-21P-C8 Note) Value at manifold
B port size: 01, C4, C6, C8, N3, N7, N9.
Grommet terminal: Double VFS2210-E-01 02 Closed center VFS2310-E-01 02 Exhaust center VFS2410-E-01 02 Pressure center VFS2510-E-01 02 DIN terminal: Double VFS2210-D Y-01 02 Closed center VFS2310-D Y-01 02 Exhaust center VFS2410-D Y-01 02 Pressure center VFS2510-D Y-01 02 With light/surge voltage suppressor 151 (3 position: 159) Lead wire O.D.
C A A B B D D Dimensions Dimensions (mm) (mm) A B C D E F G H I J Y A B C D E F G H I J Y Model Model ZPX40HBJ25-01-A18 ZPX63HBJ25-01-A18 109 160 120 171 50-01-A18 50-01-A18 144 195 155 206 40 41 28 43 20.5 32 47 69 13 63 65 46 68 31.5 43 58 80 21.5 75-01-A18 75-01-A18 180 231 191 242 ZPX50HBJ25-01-A18 ZPX80HBJ25-01-A18 112.5 163.5 125.5 176.5 50-01-A18 50-01-A18 147.5 198.5 160.5 211.5 24