10 50 100 150 200 250 15 600 500 400 300 200 100 20 200 400 600 800 1000 25 200 400 600 800 1000 1200 1400 Flow rate Q [kg/h] ( ): Saturated steam holding heat (kcal/kg) ( ): Saturation temperature (C) For Water How to read the graph The pressure differential to generate a flow rate of 25 L/min water is as follows.
IP63, JIS C 0920 Rainproof construction Except solid state switch with timer (D-M5TL, G5NTL/F7NTL/F5NTL) and magnetic resistant 2-color indication type solid state switch (D-P5DWL). D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).
Air operated External pilot solenoid Selection Procedure Table (1) Applicable Fluids Check List Copper alloy: Standard NBR : A FKM : B EPR : C Stainless steel: S NBR : A FKM : B EPR : C Fluid Wetted part Body material Aluminum: L NBR : A FKM : B EPR : C Wetted part Seal material Applicable fluids Air (Standard, Dry) Low vacuum (Up to 101kPa) Refer to Table (1) to check that the desired fluid
Specifications: Same as standard type Relation between Port Positions and Cushion Valve Positions (Rod chamfer) Series Symbols according to mounting bracket (relation of positions) Cushion Valve Port Cushion Valve Port Cushion Valve Port Cushion Valve Port Port Cushion Valve Port Cushion Valve Port Cushion Valve A A A A A A A D D D D D D B B B B B B D B C C C C C C C CS2 Basic Foot Rod flange
auto switch: 10 to 70C (No freezing) With auto switch: 10 to 60C (No freezing) Ambient and fluid temperature ML2B Rubber bumper Cushion Piston speed Piston rod size Rod end thread Rod end thread tolerance Stroke tolerance Port size Vacuum port, Refief port 1 to 200 mm/s 0.5 to 200 mm/s C J G5-S 8 M8 x 1.25 10 12 14 M14 x 1.5 8 M8 x 1.25 10 12 14 M14 x 1.5 M10 x 1.25 M10 x 1.25 JIS Class
(1) LECSS2-T P+DP+CG3G4 G3G4 P+D P+D P P+ C C G3 D (3) (1) G4 5m 5 m (12) 1.
Indication Item Setting and selection Setting range [High] Set the temperature range of the circulating fluid SP. +0.1 C to +10.0 C +1.0 C Upper/lower temperature limit (1) High/ Low [Low] Set the temperature range of the circulating fluid SP. -0.1 C to -10.0 C -1.0 C TEMP READY signal is output when the set time has passed after the circulating fluid temperature rises/drops within the
Plug for cylinder port Silencer for EXH port Double check block Individual SUP/EXH DIN rail mounting SY Built-in silencer SYJ Blank plate Name plate SX VK VZ VF Except for S kit Except for L kit Except for C kit Except for C kit Except for C kit Except for C kit VFR VP7 P.1.10-26 P.1.10-21 VP4 VQ Except for S kit Except for S kit Except for S kit Except for S kit VQ4 VQZ P.1.10-66 P.1.10-
Basic Rc(PT)P Rc(PT)P GA H2 NN NN GB H1 MM I ND D NB NE C Effective Thread E E NF N JC 10 10 N JD A K F NA S+Stroke F H B WH ZZ+Stroke (mm) Stroke range (mm) 200 to 700 200 to 700 200 to 1000 200 to 1000 Bore (mm) 20 25 32 40 Eff. thread length 15.5 19.5 19.5 21 H1 5 6 6 8 H 44 48 51 54.5 GB 47.5 49.5 51.5 51.5 GA 53.5 56.5 55 56 F 16 16 19 21 E 14.5 18 18 20.5 D 10 12 12 16 C 40.5 45.5 51.5
]) Approx.17 (4.5 [gal]) Circulating fluid port Rc 3/4 Facility water C/MPa 10 to 25 / 0.3 to 0.7 (45 to 100 [PSIG]) Required flow of facility water*9 (50Hz/60Hz) L/min 5/5 6/6 15/22 18/23 (1.3/1.3[gal/min]) (1.6/1.6[gal/min]) (4.0/5.8[gal/min]) (4.8/6.0[gal/min]) Facility water port Rc 1/2 Power supply 3-phase 50/60Hz AC200/200 to 208V10% Main breaker size A 30 60 W415D1080 Dimensions*7
200 P = 0.5 MPa m MGTL63 P = 0.5 MPa 100 MGTM63 100 Load mass m (kg) Load mass m (kg) Larger than 100st Larger than 50st 50 40 50st or smaller 75, 100st 30 20 50 25, 50st 40 10 l 30 5 4 3 m 20 2 10 1 10 20 30 40 50 100 200 300 1 2 3 4 5 10 20 30 40 50 100 200 300 400 Eccentric distance l (mm) Eccentric distance l (mm) 300 300 200 MGTL80 P = 0.5 MPa 200 MGTM80 P = 0.5 MPa 100 Load mass m
fluid temperature [C] [60 Hz] Circulating fluid temperature [C] 012 018 024 A W HRS -20 (Single-phase 200 to 230 VAC) 1000 1000 Ambient 40C Ambient 32C Ambient 25C Ambient 40C 800 800 600 600 Ambient 32C 400 400 Ambient 5C Ambient 20C Ambient 25C Ambient 5C Ambient 20C 200 200 0 5 10 15 20 25 30 35 40 45 0 5 10 15 20 25 30 35 40 45 [50 Hz] Circulating fluid temperature [C] [60 Hz] Circulating
(ARBQ5000-00 A B C 1 5) q AXT632-25-6 (M4 x 114) 4 Valve + Interface regulator SQ w AXT632-66-1 (M4 x 64) 2 Not necessary when mounting the sub-plate.
-m LECSS2-m L11 L21 For single phase 200 VAC For three phase 200 VAC L1 CNP1 NFB MC CNP3 L1 CNP1 NFB MC CNP3 Single phase 200 to 230 VAC Three phase 200 to 230 VAC L2 L2 U U U Motor V U Motor V L3 L3 V V W M N W M N() W W P1 P1 PE PE P2 P2 CNP2 CNP2 P P(+) Regeneration option Regeneration option C C D D Detector Detector CN2 CN2 L11 L11 L21 L21 Note) For single phase 200 to 230 VAC, power
AD27-A With bowl guard AD27-C-A AD37-A AD47-A Normally open (N.O.)
How to Order B 20 30 D C CQSY Without auto switch F9BW S B 20 30 D C CDQSY With auto switch Number of auto switches Built-in magnet 2 pcs. 1 pc. n pcs.
ML2B 0.020 0.018 0.016 0.014 0.012 0.010 0.008 0.006 0.004 0.002 0.000 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 Pressure MPa Pressure equivalent to sliding resistance Smooth operation with less sticking and slipping CA2D50-200N CQSYB12 -30DCM C J G5-S Average speed Average speed 2.52mm/s Speed mm/s Displacement mm Displacement mm 3.0 CV 2.60 mm/s 0 Speed wave form -3.0 MVGQ CA2YD50-200 Operating direction
100 100 Load weight m(kg) Load weight m(kg) 63 63 63 50 50 50 50 40 30 50 40 30 MLGC 40 40 40 CNA 20 20 10 10 CB 5 4 3 5 4 3 CV/MVG 2 2 CXW 1 100 200 300 400 500 1000 1 100 200 300 400 500 1000 CXS Max. speed V(mm/s) Max. speed V(mm/s) CXT Graph n Graph c 0.4MPa P < 0.5MPa 0.4MPa P < 0.5MPa 1000 1000 MX 100 100 100 500 400 300 500 400 300 80 80 80 MXU 100 100 100 63 63 63 200 200
Therefore, if the target temp. is 23.0 C and 1.5 C is set in this item, the warning [WRN] arises when temp. lowers 21.5 C. H i g h T e m p . C u t o f f M O D E < 7 0 . 0 C 8. High Temp. Cutoff Setting range : 11.0 to 70.0 C Min. increment : 0.1 C Indicated content : High temp. cutoff by internal temp. sensor (Ex. : 70.0 C).