Stations: 02 (2 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 40 (5 to 40 L/min), Return Unit Components: S (w/Flow Adj.
Stations: 02 (2 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 40 (5 to 40 L/min), Return Unit Components: S (w/Flow Adj.
Stations: 02 (2 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 40 (5 to 40 L/min), Return Unit Components: P (w/o Flow Adj.
Function: 2 (2 Position Double), Piping: 4 (Base Mounted), Exhaust: 4 (Base), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: D (DIN Terminal w/Connector), Light/Surge Suppressor: Z (With light/surge voltage suppressor), Manual Override: D (Push-turn Locking Slotted Type), Port Size: 04 (1/2), Thread: F (G)
Function: 2 (2 Position Double), Piping: 4 (Base Mounted), Exhaust: 4 (Base), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: D (DIN Terminal w/Connector), Light/Surge Suppressor: S (Surge Voltage Suppressor), Manual Override: D (Push-turn Locking Slotted Type), Port Size: 04 (1/2), Thread: N (NPT)
Stations: 06 (6 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: P (w/o Flow Adj.
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: E (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V; Temp.: None; Temperature Sensor: None)
Stations: 05 (5 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: Rc, Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj.
Stations: 08 (8 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj.
Stations: 10 (10 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj.
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: L2 [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate/Temp.: Switch Output (N/P); Temperature Sensor: None]
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: L2T [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate/Temp.: Switch Output (N/P); Temperature Sensor: Yes]
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: L2 [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate/Temp.: Switch Output (N/P); Temperature Sensor: None]
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: L2T [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate/Temp.: Switch Output (N/P); Temperature Sensor: Yes]
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: L2 [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate/Temp.: Switch Output (N/P); Temperature Sensor: None]
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: L2T [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate/Temp.: Switch Output (N/P); Temperature Sensor: Yes]
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m)
Stations: 06 (6 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj.
Stations: 06 (6 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: P (w/o Flow Adj.