HS Auto switch Auto switch 12 8.5 24.5 16 A B A B 33 38.2 Auto switch mounting position Auto switch mounting height (mm) (mm) Auto switch model D-C7, C8 D-H7 D-H7W D-H7F D-H7BA D-H7 D-H7C D-H7W D-H7BA D-C7, C8 D-C73C D-C80C D-B5, B6 D-C73C D-C80C D-B5, B6 D-B59W D-G5NT D-H7C D-G5NT D-B59W D-H7F Bore size (mm) A A B A B A A HS HS HS B B B B A 20.5 (28.5) 14.5 (22.5) 17.5 (25.5) 19.5 (27.5)

VZ 1 (P) 3 (R) VS VFN Latching type (A) 2 1 (P) 3 (R) Clean Series Clean series is available for both standard and option specifications.

-60GD B1 2 2n1-M5 x 0.8 [4(A), 2(B) port] [With external pilot] 13.3 (Pitch) P = 10.5 13.3 24 24 16.2 16.2 17 36.7 34 34 B 2 B 2 B 2 B 2 B 2 2 B 2 2 B 2 B B R B 2 PE R 3 3 R 3 R 3 1 P 1 P P 1 P 1 X A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 4-One-touch fitting [1(P), 3(R) port] Applicable tube O.D.: 8 2-One-touch fitting (X, PE port) Applicable tube O.D.: 6 2n-One-touch fitting [4(A), 2(B) port

PF2A5--2 (With voltage output type) PF2A511, 521, 551 B Wiring 116 23 1.6 76.2 Brown (1) DC(+) Main circuit Black (4) OUT (Output for display unit) White (2) NC/Analog output 54 44 34 Blue (3) DC() Use this sensor by connecting it to a P/A remote type display unit Series PF2A2/3. 4-4.5 2-Port size 30 40 50 Connector pin numbers 2 1 (44.2) A 4 3 (mm) A B Output specification Pin no.

Prior to using SMC products, please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products. *3) Vacuum pads are excluded from this 1 year warranty. A vacuum pad is a consumable part, so it is warranted for a year after it is delivered.

Signal name Description 1 +24 VDC Power supply connection to operate this product. 2 0 V 1 2 3 4 3 F . G. Ground terminal with 100 or less to use it as a reference electric potential of offset voltage. 4 Error signal The error signal turns OFF when a high voltage alarm or output signal over current is generated.

Sub-plate Nil Without sub-plate 02 With sub-plate (port size: 1/4) Sub-plate single type VQ2000 PW 02 Dimensions 4 2-4.5 mounting hole 89.4 Manual override Indicator light VQ210 --02 37 45 5 121 (DC) 130.1 (AC) 22.4 (86.3) (AC) 15.5 (77.1) (DC) Clamp screw M5 x 0.8 External pilot port 78.5 (AC) 72.6 (DC) 70.7 25 25 25 15.4 12 5 2.5 14.5 19.5 G 3/8 Electrical entry 43.8 39.1 53.6 IP65

When mounting the cylinder body with mounting bolts, use tightening torques in the table below as a guide. 2. Since a lateral load (eccentric load) cannot be applied to the piston rod, build your mounting jig in such a way that a lateral load will not be applied to the piston rod. 3.

View A PFA3-B DIN rail type Sensor Blue Brown Black Analog output 1 2 3 4 3 x 7.2 (= 21.6) 8-M3 36 15 6.4 2 3.4 5 6 7 8 OUT1 N.C. Load Load 2 1 3 4 6.5 12 to 24VDC + 26 SMC FLOW SWITCH PFA312-(-M) 35.5 30 15.2 56 (4.5) 44 UNIT RESET SET Sensor Blue Brown Black Analog output 1 2 3 4 5 6 7 8 5 6 7 8 29 OUT1 N.C.

VV3Q11 (L5) (L4) (L3) (8.5) 88 L2 48.7 L1 Plug ass'y VVQ100-12A2 3 1 (35) (45) 33 (5.5) 23.5 12.3 E 3 2 R11(Min. bending inner radius) 21.5 Manual override (29.3) 104 D side U side Stations 1 2 3 4 5 n 2-M50.8(E port) 2-M50.8(P port) 42.9 A A (8.5) 20 5 15 (7.5) 5 (A port) n-M50.8 15 P=10 Dimensions n: Stations(Max.18 stations) Equation : L1=10n+32 L2=10n+43 n L 2 52 63 83 112.5 123 3 62

(Value in the initial stage.) 1 (P) 3 (R) Normally closed VQZ VZ (A) 2 VS 1 (P) 3 (R) Normally open Option Specifications Latching AC Large flow capacity Type Item Normally open 1 2 VQ120-l VQ110L-l VQ110l (A) 2 VQ110U-l Model 0.7MPa 0.6MPa 0.5MPa Max. operating pressure 3 2 0.14mm2 (Cv ) 1 2 0.68mm2 (Cv ) 0.20mm 2 (Cv ) 2 1 Effective area 0.008 0.038 0.011 1 (P) 3 (R) 0.20mm2 (Cv ) 2 3 0.68mm2

In locations where the body is exposed to water, dust, etc., there is a possibility that they can enter into the body through the breathing hole. Using a fitting/tube (M-3AU-3 fitting and TIU01tube are recommended), install piping extended to a location where there is no water, dust, etc. 1. Do not use a lubricator on the supply side of this product, as this can cause a malfunction.

Plugging one of the cylinder ports (A or B) enables use as a 3 port valve. lt should not be used in special applications such as use as a non-leakage valve. Make sure the exhaust port is open if used as a 3 port valve. Solenoid {X) represents plugged port. common Exhaust ifflg"o,BJ"". rnd Pilot valve I Exhaust air from pilot valve will flow to main valve exhaust port.

Method of Mounting Two Auto Switches at the Stroke End of a Cylinder for Strokes Less Than 20 mm Auto switch model Applicable strokes 15 mm stroke 20 mm stroke 15 6 3 A 6 A 20 0.5 D-M9m(V) D-M9mW(V) D-M9mA(V) 0.5 3 6 B 6 B The correct mounting position of the D-M9 is 3 mm from the end face of the switch holder (dimensions A and B).

of gravity (mm) a = 3000 2000 m L1 0 10 20 30 Transfer load m (kg) L2 600 L2 (mm) 400 Mer Rolling Yawing m 200 L2 Mer 0 10 20 30 Transfer load m (kg) m 4000 a = 1000 L3 (mm) L3 a = 3000 a = 2000 2000 m Mey a 0 10 20 30 Transfer load m (kg) Refer to page 183 for deflection data. 148 3 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650)

Plugging one of the cylinder ports (A or B) enables use as a 3 port valve. lt should not be used in special applications such as use as a non-leakage valve. Make sure the exhaust port is open if used as a 3 port valve. Solenoid {X) represents plugged port. common Exhaust ifflg"o,BJ"". rnd Pilot valve I Exhaust air from pilot valve will flow to main valve exhaust port.

N04 VH40 -N06 Scale: 35% 4 (B) 2 (A) 4 (B) 2 (A) 25 25 1 (P) 3 (R) 1 (P) 3 (R) 102 88 102 89 46.6 46.6 81 88 94 144 144 97 97 123 135 107.5 105.5 1 (P) 3 (R) 1 (P) 3 (R) 17 25 19 2 4-1/4,3/8,1/2NPT 4-3/4NPT VH42 -N06 (Bottom porting) VH42 -N02/N03/N04 (Bottom porting) 2 (A) 2 (A) 46 54 1 (P) 3 (R) 1 (P) 3 (R) 4 (B) 4 (B) 4-3/4NPT 4-1/4,3/8,1/2NPT 6 Body Mount/Dinensions Series VH (mm) /

A 3 position pressure center solenoid valve and regulator with check valve can be replaced with two 3 port normally open valves and a regulator with relief function. 1. Be certain to use an pneumatic circuit which will apply balancing pressure to both sides of the piston when in a locked stop.

37-81A-3-6 3 14 SY3000-37-81A-3-7 3 58 Ass'y Assy Assy SY3000-37-80A-5 A 18 21,32SA SS5YJ3SY3000-37-80A-2 B SY3000-37-80A-7 A 916 SY3000-37-80A-4 B SY3000-37-80A-5 A 18 SY3000-37-80A-2 B 20,40, 42,43SA SS5YJ5SY3000-37-80A-7 A 912 SY3000-37-80A-4 B SY3000-37-80A-9 A 1316 SY3000-37-80A-7 B SY3000-37-80A-7 A 18 SY3000-37-80A-3 B 21,41SA SS5YJ7SY3000-37-80A-10 A 912 SY3000

Port size IDK Thread size R, Rc 1/8 R, Rc 1/4 R, Rc 3/8 R, Rc 1/2 R, Rc 3/4 R, Rc 1 R, Rc 1 1/4 R, Rc 1 1/2 Symbol 01 02 03 04 06 10 12 14 Connection type Type Male thread (with sealant) Female thread Symbol M F Plug Yes No No Yes Socket Yes Yes No No Availability Built-in check valve Note) A plug with check valve should be used in combination with a socket with check valve.