Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Air cushion, Auto Switches: M9P, Lead Wire

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9P, Lead

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, Cushion: Rubber cushion, Operating Pressure(MPa): 0.08 to 0.7, Specification: Built-in magnet, Auto Switches: Without

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, Cushion: Rubber cushion, Operating Pressure(MPa): 0.08 to 0.7, Specification: Built-in magnet, Auto Switches: Without

EX) Base: 6 stations, common EXH, A & B port Rc 1/2 VVPA450-061-04 1 pc. VPA4154-00 3 pcs. VPA4254-00 2 pcs. XT038N-4A 1 pc.

consult with SMC. 2 15A 1 2 15 14 3 20 16 20A 3 4 25 4 25A 1 Nil: Non-locking push type Valve size 5 to 7 32A 22 11 4 5 32 1 B 32F 22 32 28 40 6 28 40 1 4 Flange 11 2 40A Note) Semi-standard 1 2 1 B 40F Flange Electrical entry/With light/surge voltage suppressor 2 50A 33 Symbol Electrical entry Valve size 1 to 4 Valve size 5 to 7 7 50 2B 50F 33 50 Flange G GS E EZ T TZ D DZ Grommet Grommet

B N.O. 1/2 G 15 With surge voltage suppressor C 110 VAC Stainless steel D 200 VAC 5 20A H C37 N.C. 3/4 20 E 230 VAC C N.O. J Stainless steel F 24 VDC 6 25A N.C. K C37 Stainless steel 1 25 G DIN terminal 24 VDC D N.O.

B Grommet 100 VAC With surge voltage suppressor 12 One-touch fitting C 110 VAC G H J K 3/8 D 200 VAC 4 10A C37 N.C. 1/2 E 230 VAC 15 15A 3/8 Stainless steel B N.O. F 24 VDC 1/2 G DIN terminal 24 VDC L M 5 20A C37 N.C. With surge voltage suppressor 3/4 20 H 100 VAC C N.O. Stainless steel J 110 VAC 6 25A N.C. N P C37 Stainless steel 25 1 K 200 VAC D N.O. L 230 VAC 7 32A N.C.

Replacement pilot valve for the JSY3000/5000 b-side pilot valve 2 Pilot valve mounting screw (M2 x 16.5) Tightening torque: 0.15 Nm B tight flat head screw (M1.7) Tightening torque: 0.12 Nm 2 Pilot valve mounting screw (M2 x 25) Tightening torque: 0.15 Nm Loosen B tight at head screw to remove the pilot cover in the direction indicated by the arrow q.

Note) A: Non-locking push type A (projecting) 1 6A 8A 10A 10A 15A 20A 25A 32A 40A 50A 1 8 1 4 3 8 3 8 1 2 3 4 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 4 Note 2) Valve size 1 to 4 10 5 6 Note 2) Note) B: Slotted locking type B (tool required) 7 Note 2) 2 15 Note 1) CE-compliant: For D or DZ only Note 2) Semi-standard Note 3) For other rated voltages, please consult with SMC. 3 20 25

The new AW-B is available in four body sizes with piping from 1/8" to 1" in Rc, NPT and G thread types. Modular type filter regulator.; Transparent bowl guard.; Available with built-in backflow mechanism.; Rc, G(PF) or NPT threads.; Series 25A-AW-B is compatible with secondary battery applications

The new AW-B is available in four body sizes with piping from 1/8" to 1" in Rc, NPT and G thread types. Modular type filter regulator.; Transparent bowl guard.; Available with built-in backflow mechanism.; Rc, G(PF) or NPT threads.; Series 25A-AW-B is compatible with secondary battery applications

Magnet: D (Built-in Magnet), Series: J2W, Mounting: B (Basic Style), Bore Size: 10mm, Stroke: 60mm, Cushion: A (Air Cushion), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)

Magnet: Built-in, Mounting: Rod Flange, Bore: 10mm, Stroke: 60mm, Head Cover: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting: Band Mounting, Cushion: Air Cushion, Series: J2

Magnet: Built-in Magnet, Series: J2W, Mounting: Axial Foot, Bore Size: 10mm, Stroke: 60mm, Cushion: Air Cushion, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: Band Mounting

Magnet: Built-in Magnet, Series: J2W, Mounting: Basic Style, Bore Size: 16mm, Stroke: 60mm, Cushion: Air Cushion, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: Band Mounting

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Air cushion, Auto Switches: None, Lead Wire

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Air cushion, Auto Switches: None, Lead Wire

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Air cushion, Auto Switches: None, Lead Wire