Calculation of kinetic energy E1 12 15 25 11 7 6 5 Kinetic energy E1 Use Formula to calculate E1. Substitute 50 for m and 0.3 for . 4. Calculation of kinetic energy E1 Using the equation suitable for the classification of impact.
to 600 Accumulated pulse output wiring examples NPN 2 output type LFElAlll NPN + Analog output type LFElClll/LFElDlll Max. 28 V, 80 mA Black OUT1 Load White OUT2 (LFE A only) Load 0 V or Blue DC () 50 ms 50 ms PNP 2 output type LFElBlll Brown DC (+) Black OUT1 Max. 80 mA Load White OUT2 0 V or Load 50 ms 50 ms * When accumulated pulse output is selected, the indicator light is turned off
K J E Size variations Standard strokes Model Auto switch 20 30 40 50 100 60 70 80 90 C(D)U20 20 to 32 Direct mounting type auto switch C(D)U25 C(D)U32 Features 2 Free-Mounting Cylinder with Air Cushion Series CU 20, 25, 32 How to Order CU 32 32 50 50 A A F9BW With auto switch CDU Without auto switch Number of auto switches With auto switch (built-in magnet) 2 pcs. Nil S 1 pc.
Unrestricted 300/50 m/s2 Lubrication Mounting orientation Impact/Vibration resistance Enclosure(2) Dustproof Grommet (G), DIN terminal (D) 100, 110, 200, 220, 240 V 6, 12, 24, 48 V 10% of rated voltage 9.5 VA/50 Hz, 8 VA/60 Hz 7 VA/50 Hz, 5 VA/60 Hz 3.5 VA/50 Hz, 3.3 VA/60 Hz 3 VA/50 Hz, 2.8 VA/60 Hz 4 W (Standard), 2 W (Low power consumption type) 4.3 W (Standard), 2.3 W (Low power consumption
LED display.32 10. 1 LED display.32 10. 2 Controller IF communication status and LED display.33 11. Mode.34 11. 1 Outline.34 11. 2. Step data input mode .34 11. 3. Numerical data input mode.34 11. 4. Data writing mode.36 12.
D1 D2 L1 L2 M A 5 32 3 16 3 16 1 4 1 4 5 16 5 16 3 8 3 8 1 2 1 2 KQ2L01-03 KQ2L01-05 KQ2L03-05 KQ2L03-07 KQ2L05-07 KQ2L05-09 KQ2L07-09 KQ2L07-11 KQ2L09-11 KQ2L09-13 KQ2L11-13 9.6 7 10 10 8 3 7 6 3 8 11 12 17 17 30 25 17 17.5 25 13.5 2.2 2.5 3 2.5 1 8 15.5 33 33.5 26 34.5 35.5 36.5 37.5 40.5 41.5 43 21.5 22.5 14.5 23.5 23 24.5 23.5 5 32 16 18 10.4 3 16 3.5 16.5 19.5 10 11.4 1 4 4.6 17 20.5
override Rated voltage Nil Push type 1 2 3 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz B Locking type (Slotted) C Locking type (Manual) 110 to 120 VAC, 50/60 Hz 4 Surge voltage suppressor Option 220 VAC, 50/60 Hz Indicator light 24 VDC 12 VDC 5 6 Light/Surge voltage suppressor E EZ Nil None 7 240 VAC, 50/60 Hz With light/surge voltage suppressor (Type E, T, D, or Y only) 9 Other Z Option S With
Hole diameter 5 9 Features 1 3 Port Direct Operated Poppet 3 Port Direct Operated Poppet Solenoid Valve Series VKF300 How to Order Valves Electrical entry Rated voltage 100VAC 50/60 Hz 200VAC 50/60 Hz 110VAC 50/60 Hz 220VAC 50/60 Hz 24VDC 12VDC 240VAC 50/60 Hz Other DO-DIN terminal (without connector) 1 2 3 G-grommet (lead wire length: 300mm) H-grommet (lead wire length: 600mm) D-DIN type
F F MHL2-10D Z-X85 MHL2-16D Z-X85 1 2 1 2 MHL2-10DZ-X85 MHL2-16DZ-X85 25 25 70 60 70 60 20 20 Pressure 0.6 MPa Gripping force [N] Gripping force [N] Gripping force [N] Gripping force [N] Pressure 0.6 MPa Pressure 0.6 MPa 50 50 Pressure 0.6 MPa 0.5 MPa 0.5 MPa 15 15 40 40 0.5 MPa 0.5 MPa 0.4 MPa 0.4 MPa 30 30 10 10 0.4 MPa 0.4 MPa 0.30 MPa 0.3 MPa 20 20 5 5 10 10 0 0 10 20 30 40 50 60 70 0
(For details, refer to "Specific Product Precautions 1" on Page 11.)
25 10 25 Ball screw specifications Shaft length [mm] Stroke + 284.5 Lead [mm] 50 25 10 Impact/Vibration resistance [m/s2] *5 50/20 Actuation type Ball screw Guide type Linear guide Operating temperature range [] 5 to 40 Operating humidity range [%RH] 90 or lessNo condensation 4.58 Actuation unit weight [kg] specifications 0.43 0.05 Other inertia [kgcm] Other *6 Friction coeffcient 0.8 Mechaincal
11 11 23 11 23 SOL.A SOL.B SOL.B Light/Surge voltage suppressor Station 10 Station 10 SOL.A SOL.A 10 10 Light/Surge voltage suppressor Light/Surge voltage suppressor 15 15 15 SOL.B SOL.B SOL.B Station 2 Station 2 Station 2 2 2 SOL.A SOL.A SOL.A Light/Surge voltage suppressor Light/Surge voltage suppressor Light/Surge voltage suppressor 2 SOL.B SOL.B SOL.B 14 Station 1 Station 1 14 14 Station
CNG D-G39/K39 11 11 10 MNB Since the operating range is provided as a guideline including hysteresis, it cannot be guaranteed (assuming approximately 30% dispersion). It may vary substantially depending on an ambient environment. CNA CNS CLS CLQ RLQ MLU MLGP ML1C The above figure shows the mounting example of D-A9(V)/M9(V)/M9W(V)/ M9A(V)L.
End Lock Cylinder Standard type CA2 Standard type CA2W Standard/Non-rotating rod CA2K Standard/Non-rotating rod CA2KW Low friction CA2Q 40, 50, 63, 80, 100 Series CBA2 How to Order L L 150 150 Y7BW 50 50 H H N N CBA2 CDBA2 Without auto switch With auto switch Number of auto switches With auto switch Nil S n 2 pcs. 1 pc. n pcs.
LED display.34 10. 1 LED display.34 10. 2 Controller IF communication status and LED display.35 11. Mode.36 11. 1 Outline.36 11. 2. Step data input mode .36 11. 3. Numerical data input mode.36 11. 4. Data writing mode.38 12.
35.6 36.8 43.6 44.6 23.5 24.2 25.2 32.6 33.7 35.2 32.6 38.3 39.1 40.6 41.8 51.1 52.1 20.7 21.4 23.5 24.2 6 7 8 12 13 22 25 36 40 44 48 85 89 6 7 12 9 12 18 16 24 22 25 36 40 52 93 106 38 39.2 40.7 40.7 44.8 53.2 59.8 59 64.4 71.6 76 77.7 82.1 4.5 5.2 6.2 5.2 6.3 6.7 8.1 7.4 8.2 9.8 11 38 39.2 48.7 40.7 40.7 50 52.2 52.2 54.4 59.8 59 64.4 70.8 76.9 83.1 8.4 9.3 11.6 9.3 11.6 12.8 15.2 12.8
Table 15 Parts where grease is to be applied Application of grease Grease Body (inner sliding surface) Piston(Seal groove) Slider(Sliding surface) GR-S-010 Piston seal Tube gasket 23 24 25 O-ring 5 11 1 16 12 7 23 24 12 11 4 25 4 24 25 23 -34- (2) Mount the tube gasket 11 to the left cover 3 to mount to the body 1 . (3) Insert the rack 16 and the piston 4 into the body 1 .
Refer to back page 50 for Safety Instructions and pages 3 to 9 for 3/4/5 Port Solenoid Valve Precautions.
Then, Sending completed [IN: 19.0]changes from 1 to 0. 35 - 11.