(Example) SS3YJA7-41-03-01. 1 set SYJA714 . 2 sets SYJ700-10-2A . 1 set (Example) SS3YJA5-40-03-01. 1 set SYJA514 . 2 sets SYJ500-10-3A . 1 set The asterisk denotes the symbol for assembly.
(guideline) Command 2400bps 19200bps 57600bps EE 145 25 10 EU 105 20 10 AB 105 20 10 MO 245 35 15 MD 115 20 10 OE 130 20 10 Calculation Example) Number of controllers connected: 5 Required transmission commands: EE,EU, AB Communication response time ( 25 + 20 + 20 ) x 5 = 325 ms Response time (guidline) 500 450 400 Response time [ms] EE 350 EU,AB,MD,OE 300 MO 250 200 150 100 50 0 1 2 3 4
kPa 25 kPa 50 kPa Electrical Power supply voltage 12 to 24 VDC (10%), and power supply ripple (p-p) 10% at max. spec.
(Example) SS3YJ7-20-03 . 1 set (manifold base) SYJ712-5LZ-01 . 2 sets (valve) SYJ700-10-1A . 1 set (blanking plate assembly) SS3YJ7-42R-03-01 . 1 set (manifold base) SYJ714R-5G . 2 sets (valve) SYJ700-10-2A . 1 set (blanking plate assembly) The asterisk denotes the symbol for assembly.
Without adjuster type is not available for the 11-MXP6 series. 11-MXP How to Order MXPJ6 Clean series 11 Vacuum suction type 11 MXPJ6 10 22 MXPJ6 10 11-MXPJ6 Copper, fluorine and silicone-free + Low particle generation Stroke 5 10 5 mm 10 mm 22 Vacuum suction type With auto switch type is not available for the 11-MXPJ6 series.
218 210 to 420 Max. speed[mm/s] *1 *3 400 200 100 400 200 400 200 Actuator specifications Pushing speed[mm/s] 20 to 30 10 to 30 5 to 30 20 to 30 10 to 30 20 to 30 10 to 30 Max. acceleration/deceleration[mm/s2] 5000 Positioning repeatability [mm] 0.01 Lost motion[mm] *4 0.1 or less Screw lead[mm] 10 5 2.5 12 6 16 8 Impact/Vibration resistance[m/s2] *5 50/20 Actuation type Ball screw (In-line
1122Series MXP/MXPJ6 Air slide table 6, 10, 12, 16 How to Order Clean series 11 Vacuum suction type MXP 11 12 15 M9N MXP 22 12 15 M9N Copper, fluorine and silicon-free + low particle generation Number of auto switches Nil s n 2 pcs. 1 pc. n pcs. 22 Vacuum suction type Bore size Stroke mm Type of auto switch 6 10 12 16 5, 10 10, 20 15, 25 20, 30 Nil Without auto switch Refer to the table
10 VX 0 0 10 30 40 50 20 60 VX3 10 20 Discharge rate (l/min) Discharge rate (l /min) VXA Selection from Flow Characteristic Graph (PA3000) VN Required specifications example: Find the pilot air pressure and pilot air consumption for a discharge rate of 6 l/min and a total lifting range of 25 m.
140 100 95 90 85 80 75 70 65 60 Flow rate (l/min (ANR)) VAC side pressure (kPa) IRV20-C10 (One-touch fitting 10) IRV20 53.0 0 10 53.5 SET side pressure (kPa) 20 54.0 Set pressure (kPa) 30 54.5 40 55.0 50 55.5 60 56.0 70 Set point 56.5 80 90 57.0 100 95 90 85 80 75 70 65 60 0 50 100 150 200 250 Flow rate (l/min (ANR)) VAC side pressure (kPa) 2 Vacuum Regulator Series IRV10/20 Construction
For detecting fine pressures, warm up the product for 10 to 15 minutes. Check if the product satisfies the specified accuracy after 10 minutes warm up time. Insufficient warm-up time Product failure Replace the product. -69No.PS-OMU0003-D Problem No.
ZS-40-M Taptite screw for PF3W711 (4 x 10), 4 pcs.
For detecting fine pressures, warm up the product for 10 to 15 minutes. Check if the product satisfies the specified accuracy after 10 minutes warm up time. Insufficient warm-up time Product failure Replace the product. -70No.PS-OMU0006-D Problem No.
0.31 0.28 0.31 0.28 U W M5 x 0.8 U W 597 4 Port Direct Operated Poppet Solenoid Valve 10-VQD1000 Dimensions L plug connector: 10-VQD1121-L-M5 M plug connector: 10-VQD1121-M-M5 Directional Control Valves Air Grippers Modular F.
ATTACHMENTS / ACCESSORIES OPTIONS PART NUMBER Attachments / Accessories (Options) part number Section Model Descriptio For AC10*-A For AC20*-A For AC25*-A For AC30*-A For AC40*-A For AC40*-06-A Note1) Pressure gauge Standard G27-10-01 G36-10-01 G46-10-01 Round type G27-10-01 Note2) G36-4-01 G46-4-01 0.2 MPa setting Round type Standard G36-10-01-L G46-10-01-L Option G36-4-01-L G46-4-01-L
Operator Buna N 10 Recssed Non-Lockihg OPeralor PB 0103 61 l Scrws' Pilot Covers (4) Hold Down Bolt (8.32 x 1 Y'!')
Specification for Option L 10 1 Safety instructions . 10 1 10 2 Specification . 10 1 10 3 Maintenance . 10 2 Chapter 11 Specification for Option M 11 1 Safety instructions . 11 1 11 2 Specifications . 11 2 11 3 Cautions for handling the motor type auto drain . 11 2 11 4 Electric circuit . 11 2 Chapter 12 Specification for Option R 12 1 Safety instructions . 12 1 12 2 Specifications . 12
Operator Buna N 10 Recssed Non-Lockihg OPeralor PB 0103 61 l Scrws' Pilot Covers (4) Hold Down Bolt (8.32 x 1 Y'!')
For a 10 orifice (VXS23/Port size 1/4), P 0.05 MPa The optimum size for a pressure differential of P 0.2 MPa and a flow of 50 L/min will be the VXS23 (10 orifice, port size 3/8). 500 400 VXS26 25 Cv = 12 300 VXS25 20 Cv = 9.2 200 VXS24 15 Cv = 5.3 Flow rate Q [L/min] 100 VXS23 Port size 3/8 10 Cv = 2.8 VXS23 Port size 1/4 10 Cv = 2.4 50 40 30 25 20 10 0.01 0.02 0.03 0.04 0.05 0.1 0.2 0.3
10 0 0 10 30 40 50 20 60 10 20 Discharge rate l/min Discharge rate l/min Selection from flow rate characteristic graphs (PA3000) Required specification example: 3.
15 20 25 32 10, 20, 30, 40, 50 M5 x 0.8 10, 20, 30, 40, 50, 75, 100 1/8 Double acting (Both sides) Non-lube 10-/12-/21-CXS6 6 Single rod 10-/12-/21-CXS10 10-/12-/21-CXS15 10-/12-/21-CXS20 10-/12-/21-CXS25 10-/12-/21-CXS32 10, 20, 30, 40, 50 10 15 20 25 32 M5 x 0.8 10, 20, 30, 40, 50, 75, 100 1/8 Specifications Suction Flow Rate of Vacuum Suction Type (Reference values) Bore size (mm)