Adapter connection thread Symbol Thread dia. 1 A8 Symbol Pad dia. 1 02 to 08 2 A10 B5 2 10 to 16 3 A14 3 20 to 32 B8 4 40, 50 T 2 ZP B5 [q Adaptor] S ZP 06 B5 R [w Type R adaptor] Buffer connection thread B5 Symbol S Pad dia. 02 to 16 Pad dia.

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: A2 [URJ1/4 (Face Seal Fitting)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: A2 [URJ1/4 (Face Seal Fitting)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: A2 [URJ1/4 (Face Seal Fitting)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: A2 [URJ1/4 (Face Seal Fitting)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation

1 w @0 !8 t !4 !5 @2 @1 #2 #4 #5 #7 #6 #8 Component Parts No. Description Cylinder tube No.

) UM:-A12-06 ZP3-T (10/13/16) B:-A12-06 ZP3-T (015/02/035) U:-A3 ZP3-T (015/02/035) U:-B3 ZP3-T (015/02/035) U:-A6-@ ZP3-(015/02/035)U: ZP3A-T1-A3 ZP3A-T1-B3 ZP3A-T1-A6-B3 ZP3A-T3-A5 ZP3A-T3-B5 Note 1) ; in the table indicates the pad material.

Base material: Aluminum Fluid: Air VXE2 VXED2 VXEZ2 Common SUP Individual SUP u u w w t e t e y r q y r o o q y i y i IN OUT OUT port IN port Base material: Brass (C37), Stainless steel Fluid: Water/Oil Common SUP u w t e y r o q y OUT i IN port Component Parts Material No.

(g) n: Number of stations W = 30n + 50 W = 37n + 63 W = 61n + 101 W = 79n + 127 W = 100n + 151 Note 1) For 10 stations or more (5 stations or more in case of SS5Y7), supply pressure to P port on both sides and exhaust from EA and EB ports on both sides.

(g) n: Number of stations W = 30n + 50 W = 37n + 63 W = 61n + 101 W = 79n + 127 W = 100n + 151 Note 1) For 10 stations or more (5 stations or more in case of SS5Y7), supply pressure to P port on both sides and exhaust from EA and EB ports on both sides.

(For details, refer to page 4-4-25.) 4-4-20 3 Port Pilot Operated Solenoid Valve Rubber Seal Series SYJ500 Construction q e r t w y q e r t w y N.C. N.O.

8 stations 4 stations 02 2 stations 02 2 stations 02 2 stations (2) (2) (2) Applicable up to 20 solenoids.

D1 Reverse-connection preventing diode D2 Surge killer (Surge absorbing diode) D3 Surge killer (Surge absorbing diode) T R Output transistor W I R I N G E X A M P L E S H O W T O C H A N G E P R E S S U R E U N I T: W h e n t h e u n i t c h a n g e s w i t c h ( 5 ) U N I T i s a d j u s t e d t o e a c h p o s i t i o n , t h e u n i t a n d figures of the pressure display change.