Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: w/o Lead Wire, Bracket: A2 [Bracket B (ZS-46-A2)]
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A2 [Bracket B, Horizontal Mounting (ZS-46-A2)], Operation Manual
Example) IS10M-30-6LP Symbol Description Nq Body size 20 30 40 50 a Set pressure range Nil 0.1 to 0.4 MPa V V V V 6 Note 1) 0.1 to 0.6 MPa V V V V + Semi-standard Nil 0.5 m V V V V L 3 m V V V V Z 5 m V V V V + b Lead wire length Nw 23 15 (13) c Pressure unit of the scale plate Nil MPa V V V V P Note 2) MPa/psi dual scale V V V V (23) (5000) (3000) (500) Note 1) Set pressure range of 6P (
. 5-6-8 Series VM100 P . 5-6-12 Series VM200 P . 5-6-20 Series VM400 P . 5-6-26 Series VZM500 P . 5-6-41 Series VZM400 P . 5-6-35 Series VFM300 P . 5-6-48 Series VFM200 P . 5-6-54 Series VFM800 P . 5-6-32 Transmitters Page Relay Valve P . 5-7-1 Shuttle Valve P . 5-7-3 Shuttle Valve with One-touch Fitting P . 5-7-5 AND Valve with One-touch Fitting P . 5-7-7 Time Delay Valve P . 5-7
Nq Body size 20 30 40 50 60 Symbol Description Nw Pipe thread type Nil Rc V V V V V N*1 NPT V V V V V F*2 G V V V V V + 01 1/8 V 02 1/4 V V V 03 3/8 V V 04 1/2 V 06 3/4 V V 10 1 V V + Ne Port size a Mounting Nil Without mounting option V V V V V B*3 With bracket V V V V V + Option Nr Nil Without auto drain V V V V V C*4 N.C.
L Speed: V [mm/s] a1 a2 T1 = V/a1 = 300/3000 = 0.1 [s], T3 = V/a2 = 300/3000 = 0.1 [s] Time T = T1 + T2 + T3 + T4 [s] [s] L 0.5 V (T1 + T3) V T1: Acceleration time and T3: Deceleration time can be found by the following equation.
Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: w/o Lead Wire, Bracket: A2 (Bracket B, Horizontal Mounting), Operation Manual: K (Operation Manual, Calibration Certificate)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A2 (Bracket B, Horizontal Mounting)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A2 (Bracket B, Horizontal Mounting)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A2 (Bracket B, Horizontal Mounting), Operation Manual: K (Operation Manual, Calibration Certificate)
Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A2 (Bracket B, Horizontal Mounting)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A2 (Bracket B, Horizontal Mounting)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A2 (Bracket B, Horizontal Mounting)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A2 (Bracket B, Horizontal Mounting)
Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A2 (Bracket B, Horizontal Mounting)
Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A2 (Bracket B, Horizontal Mounting)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A2 (Bracket B, Horizontal Mounting)
-01ST 20.4 27.5 1/8" 8.4 4 9.3 5/32" 9.3 20.4 27.5 12.7 14.3 AS221F-N01-03ST AS221F-01-06ST 14.2 7 35.6 11.6 R 1/8 12 1.5 13.5 6 32 3/16" 11.4 23.1 30.2 14.3 16.5 AS221F-N01-05ST AS221F-01-08ST NPT1/8 12.7 14.2 7 35.6 1.5 32 15.2 25.3 18.5 32.4 8 AS221F-N01-07ST AS221F-01-10ST 15 1/4" 13.2 23.9 31 18.5 18.5 21 33.1 40.2 10 AS221F-N01-09ST AS221F-02-04ST 5/16" 15.2 25.3 32.4 15 21 10.4 16
L Speed: V [mm/s] a1 a2 T1 = V/a1 = 300/3000 = 0.1 [s], T3 = V/a2 = 300/3000 = 0.1 [s] Time T = T1 + T2 + T3 + T4 [s] [s] L 0.5 V (T1 + T3) V T1: Acceleration time and T3: Deceleration time can be obtained by the following equation.