SMC Corporation of America
Elite Part Number Search
Search Results "ZP2V-A01-07"

Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Effective Sectional Area(mm2): 0.38, Piping Opening: M, Nominal Designation of Piping Thread: M5, Connection Tube Diameter: -, Seal Type: Elastic Seal, Flow Coefficient (Cv): 0.020596206, Piping Size (Pad Side

Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Effective Sectional Area(mm2): 0.38, Piping Opening: One-Touch Pipe, Nominal Designation of Piping Thread: -, Connection Tube Diameter: ø4, Seal Type: Elastic Seal, Flow Coefficient (Cv): 0.020596206, Piping

Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Effective Sectional Area(mm2): 0.38, Piping Opening: M, Nominal Designation of Piping Thread: M8, Connection Tube Diameter: -, Seal Type: Elastic Seal, Flow Coefficient (Cv): 0.020596206, Piping Size (Pad Side

Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Effective Sectional Area(mm2): 0.38, Piping Opening: [NPT] G, Nominal Designation of Piping Thread: 1/8, Connection Tube Diameter: -, Seal Type: Elastic Seal, Flow Coefficient (Cv): 0.020596206, Piping Size

Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Effective Sectional Area(mm2): 0.38, Piping Opening: One-Touch Pipe, Nominal Designation of Piping Thread: -, Connection Tube Diameter: ø6, Seal Type: Elastic Seal, Flow Coefficient (Cv): 0.020596206, Piping

Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Effective Sectional Area(mm2): 0.38, Piping Opening: [NPT] NPT, Nominal Designation of Piping Thread: 1/8, Connection Tube Diameter: -, Seal Type: Elastic Seal, Flow Coefficient (Cv): 0.020596206, Piping Size

Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Effective Sectional Area(mm2): 0.38, Piping Opening: [RC] R, Nominal Designation of Piping Thread: 1/8, Connection Tube Diameter: -, Seal Type: Elastic Seal, Flow Coefficient (Cv): 0.020596206, Piping Size (

Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Effective Sectional Area(mm2): 0.38, Piping Opening: M, Nominal Designation of Piping Thread: M5, Connection Tube Diameter: -, Seal Type: Elastic Seal, Flow Coefficient (Cv): 0.020596206, Piping Size (Pad Side

Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Effective Sectional Area(mm2): 0.38, Piping Opening: M, Nominal Designation of Piping Thread: M5, Connection Tube Diameter: -, Seal Type: Elastic Seal, Flow Coefficient (Cv): 0.020596206, Piping Size (Pad Side

Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Effective Sectional Area(mm2): 0.38, Piping Opening: M, Nominal Designation of Piping Thread: M6, Connection Tube Diameter: -, Seal Type: Elastic Seal, Flow Coefficient (Cv): 0.020596206, Piping Size (Pad Side

Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Effective Sectional Area(mm2): 0.38, Piping Opening: [NPT] G, Nominal Designation of Piping Thread: 1/8, Connection Tube Diameter: -, Seal Type: Elastic Seal, Flow Coefficient (Cv): 0.020596206, Piping Size

Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Effective Sectional Area(mm2): 0.38, Piping Opening: [NPT] NPT, Nominal Designation of Piping Thread: 1/8, Connection Tube Diameter: -, Seal Type: Elastic Seal, Flow Coefficient (Cv): 0.020596206, Piping Size

Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Effective Sectional Area(mm2): 0.38, Piping Opening: One-Touch Pipe, Nominal Designation of Piping Thread: -, Connection Tube Diameter: ø4, Seal Type: Elastic Seal, Flow Coefficient (Cv): 0.020596206, Piping

Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Effective Sectional Area(mm2): 0.38, Piping Opening: One-Touch Pipe, Nominal Designation of Piping Thread: -, Connection Tube Diameter: ø6, Seal Type: Elastic Seal, Flow Coefficient (Cv): 0.020596206, Piping

The cover is translucent to make it possible to check the cable reaches the end. 3, Pressure-welding the connector Use a tool (OMRON, DWT-A01) to connect wires. (1) As shown below, place the connector cover so that its center (arrowed part) is at the center of the IDC block of the tool. -14No.EX-OMM0008-D (2) Squeeze firmly on the DWT-A01 Pliers until the lock on the connector clicks into

Base mounted manifold stacking base SS07 3 A01 08 C SS073A01-04C 1 set Manifold Base no. Valve no. Ports S070A-5BG 3 set 3 port 3 SS070A-10A 1 set Blanking plate assembly no.

SUP/EXH port (Applicable tubing) Applicable tubing 3.18/2 4/2.5 A01 A02 Barb fittings (6/4) Barb fittings Write sequentially from the 1st station on the D side. Note) The outside and inside diameters of the applicable tubing are indicated for the barb fitting.

Analog In An Analog input value from a System Input (A01, A02, A03, ... A08) FB Value An analog value contained in a Function Block (T, t, N, n, Direct set, etc.) Word Comparison a 16 bit output value from a Function Block 6.1 Boolean Function Block It is possible to express the Logic functions in the form of an equation.

A01 A02 3.18/2 Barb fittings (6/4) Barb fittings 4/2.5 Note) The outside and inside diameters of the applicable tubing are indicated for the barb fitting.

Contributes to reduction in flow consumption if suction requires flow rate. 3 x Suction Supply air Vacuum Saving Valve ZP2V Can restrict the reduction of vacuum pressure even when there is no workpiece. Connection thread size for pad side M5 x 0.8 Rc1/8 M6 x 1 G1/8 M8 x 1.25 NPT1/8 R1/8 No need for switching operation when changing workpieces.