ZK2 CH A 2 04 L A KQ2P 06 Applicable stations 02 04 06 08 10 For 2 stations manifold For 4 stations manifold For 6 stations manifold For 8 stations manifold For 10 stations manifold d Model and dimensions D Applicable size d 6 8 1/4" 5/16" Weight (g) Note A L D Symbol 06 08 07 09 White White Orange Orange 18 20.5 18 20.5 35 39 35 39 8 10 8.5 10 1 2 1 2 Connector type 1 2 D sub-connector (
(mm) Applicable fitting size 6 8 10 4 8 10 12 10 12 12 16 16 KGE10-02 R 1/4 Model 10 -03 R 3/8 KGR04-06 KGE12-03 R 3/8 12 4 -08 -04 R 1/2 -10 KGE16-03 R 3/8 16 KGR06-04 -04 R 1/2 -08 6 Tube Cap KGC -10 -12 KGR08-10 Applicable tubing O.D.
-06-06 ZH10DS-06-06-08 ZH10DL-06-06-08 ZH13DS-08-10-10 ZH13DL-08-10-10 ZH15DS-10-12-12 ZH15DL-10-12-12 12.8 6 24 21 7.8 6 17 24 12.8 6 24 21 6 17 24 12.8 6 24 22 6 17 24 12.8 6 24 22 6 17 24 13.7 6 26 24.5 8 20 28 13.7 6 26 24.5 8 20 28 15.3 10 28 27 10 22 30 15.3 10 28 27 10 22 30 Applicable tubing diameter J 7.8 7.8 7.8 9.6 9.6 10.7 10.7 ZH ZU Courtesy of Steven Engineering, Inc.-230 Ryan
Pad form Flat/Flat with ribs Deep Bellows Stroke (mm) Vacuum entry port Model 04 06 08 04 06 08 04 06 08 2004, 3507, 4010 ZPR02 to 08 Thin section flat series (10 to 16) 38 6 39 38 39 10 ZPR10 to 16 39 40 39 40 40 41 10 ZPR20 25 54 55 56 55 56 57 57 58 59 ZPR32 ZPR40 ZPR50 56 61 126 132 57 58 127 128 62 138 145 63 139 146 129 133 10 Weight by Stroke (g) Stroke (mm) Model 10 15 20 25 30 40
Pad diameter (mm) 02 04 2 4 ZCU Vacuum entry port (Refer to Table (2) for applications.) 06 6 AMJ 08 8 10 10 Misc. 13 13 Table (2) Vacuum Entry/Mounting Thread Diameter 16 16 Thread dia.
Purchasing order is available in units of 10 pieces. KQ2P-04 KQ2P-06 KQ2P-08 KQ2P-10 KQ2P-03 KQ2P-07 KQ2P-09 KQ2P-11 4 6 8 10 5/32" 1/4" 5/16" 3/8" 16 18 20.5 22 16 18 20.5 22 32 35 39 43 32 35 39 43 6 8 10 12 6 8.5 10 11.5 Port plug VVQ1000-58A The plug is used to block the cylinder port.
SY7000222-1A [for 10 valves (30 pcs.)] SY5000222-1A [for 10 valves (20 pcs.)] SY7000221-1A [for 10 valves (30 pcs.)] SY3000222-1A [for 10 valves (20 pcs.)] SY5000221-1A [for 10 valves (20 pcs.)] SY300023-24A [for 10 valves (20 pcs.)]
/B5m/B64/B59W Note 1) BD1-10M BA-04 BA-05 BA-08 BA-10 Note 1) The auto switches listed below cannot be mounted on 63.
10 6 6 8 8 10 10 300 300 300 300 300 300 600 600 600 600 600 600 KNL3-06-150 KNL3-06-200 KNL3-08-200 KNL3-08-250 KNL3-10-250 KNL3-10-300 KNL6-06-150 KNL6-06-200 KNL6-08-200 KNL6-08-250 KNL6-10-250 KNL6-10-300 O.D.
P=17.5 1 2 3 4 5 6 7 8 n: Stations 53 Silencer cover Blanking plug (For One-touch fitting) L Dimensions 04 06 08 10 Applicable fittings size d 4 6 8 10 A A L D Model KQ2PKQ2P-04 KQ2P-06 KQ2P-08 KQ2P-10 16 18 20.5 22 32 35 39 43 6 8 10 12 It is inserted into an unused cylinder port and SUP/EXH ports.
Option: Pressure gauge G15-10-01 How to Order NARM2000-4A2-N01G G15 P10 01 Symbol Units Nil MPa P PSI Common IN Individual IN IN M5 x 0.8 .39 (10) Max. pressure indication 10 150PSI (1.0MPa) .59 (15) IN OUT OUT *Pressure gauge for 30psig (0.2MPa) is not available.
When ordering with manifolds, add "-N" at the end of the manifold number. 1 2 3 4 5 6 7 8 ... n: Stations 53 Silencer cover Blanking plug (for One-touch fitting) L Dimensions 04 06 08 10 Applicable fitting size d 4 6 8 10 A Model A L D KQ2PKQ2P-04 KQ2P-06 KQ2P-08 KQ2P-10 16 18 20.5 22 32 35 39 43 6 8 10 12 This is inserted into the cylinder port and SUP and EXH ports that are not used.
, 09, 10 06, 07, 08, 09, 10 01, 23, 03, 04, 06, 07 01, 23, 03, 04, 06, 07 08, 09, 10, 11 08, 09, 10, 11 03, 04 400 200 06, 07 TMH 02 01, 23 300 50 03, 04 ASD 200 100 01, 23 AS 100 AS-FE 0 0 0 5 0 10 5 0 10 5 0 10 KE Number of needle rotations Number of needle rotations Number of needle rotations Note) -U10/32 has the same specification as M5.
, 09, 10 06, 07, 08, 09, 10 01, 23, 03, 04, 06, 07 01, 23, 03, 04, 06, 07 08, 09, 10, 11 08, 09, 10, 11 03, 04 200 400 06, 07 TMH 02 01, 23 300 50 03, 04 ASD 100 200 01, 23 AS 100 AS-FE 0 0 0 5 0 10 5 0 10 5 0 10 KE Number of needle rotations Number of needle rotations Number of needle rotations Note) -U10/32 has the same specification as M5.
Dimensions Applicable fitting size d 4 Model A L D 10-KQP-04 16 32 6 6 10-KQP-06 18 35 8 8 10-KQP-08 20.5 39 10 10 10-KQP-10 22 43 12 12 10-KQP-12 24 44.5 14 10-KQP-01 16 31.5 5 10-KQP-03 16 32 6 10-KQP-07 18 35 8.5 10-KQP-09 20.5 39 10 10-KQP-11 22 43 11.5 Series Part no 10-SY9000 SY9000-57-1A 1 8" 5 32" Cable assembly 1 4" AXT100-FC261 5 16" 3 to 3 8" Red Terminal no.
32 6 36.5 41.5 10 44 54 8.5 13.5 16 5,10 16 8 5.4 35.5 40.5 5, 10 38 8 39 44 10.5 46 56 9.5 14.5 20 5, 10 20 10 7 36.5 41.5 5, 10 47 7 41 46 11 47.5 57.5 10 15 25 5, 10 25 12 10 37.5 42.5 5, 10 52 12 42.5 47.5 10.5 50 50 12 17 32 5, 10 32 16 13.3 38 43 5, 10 45 13 45 50 11 56.5 66.5 12 17 40 5, 10 40 16 18.3 44.5 41.5 5, 10 52 13 51.5 56.5 10.5 68.5 88.5 18 28 50 10, 20 50 20 17.6 50.5 60.5
(mm) 3.2 Applicable fitting size d 4 6 8 8 10 KQ2L06-10 38.5 19 Effective area (mm2) Nylon Urethane Note) Mass (g) L1 Applicable tubing Model D1 D2 L1 L2 A M KQ2L23-04 KQ2L04-06 KQ2L04-08 2 3 11 9.6 7 8 10 17 25 26 35 13.5 15.5 3 2.5 14.5 22 18 24 D1 4 18 4.2 4.2 10.4 16 6 KQ2L06-08 12.8 10 19.5 30.5 11.4 9.0 12 17 20 33.5 21.6 14.9 20 20.5 18.5 12 KQ2L08-12 40.5 27 26 L2 8 10 KQ2L08-10 15.2
pressure: 0.5 MPa Inlet pressure: 0.5 MPa 100 200 3 400 Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) 6 Effective area (mm2) Effective area (mm2) Effective area (mm2) 06, 08 08, 10 1.0 300 06 04 2 4 50 100 200 0.5 1 2 100 0.0 0 0 0 0 0 0 5 10 0 5 10 0 5 10 Number of needle rotations (turns) Number of needle rotations (turns) Number of needle rotations (turns) ASG520F
-06-08-01S-3 33 80 83 84 17 20 15.5 12.8 45.4 17 11.1 18.5 76.5 77 78 41 6 KM14-06-08-02S-3 15.2 12.8 KM14-06-08-03S-3 1 4 3 8 1 2 10 6 KM14-06-10-02S-3 44 45 67 7.5 KM14-06-10-03S-3 18.5 12.8 KM14-06-10-04S-3 87.5 88.5 92 81.5 82 84 19 22 21 19 12.8 45.4 17 12.8 21 1 4 3 8 1 2 10 8 KM14-08-10-02S-3 48 88 89 90.5 94 95 98.5 19 71 7.5 KM14-08-10-03S-3 18.5 15.2 KM14-08-10-04S-3 22 22.5 19
EB:3/8 NPTF) O.08(:::2.!