Nozzle Diameter: 05 (ø0.5mm), Vacuum Pressure: S (-90 kPa), SUP: 06 (One-touch Fitting ø6), VAC: 06 (One-touch Fitting ø6), EXH: 06 (One-touch Fitting ø6), Accessories: NS (w/o Standard Bracket, w/Silencer)
Main Body Shape: Pipe Type, Additional Function: -, Ultimate Vacuum(kPa): -90, Air Consumption Flow Rate(l/min): 13, Vacuum Port Connecting Port Shape: Rc1/8, Vacuum Port One-Touch Fitting Size: -, Air Supply Port Connecting Shape: One-Touch Couplings, Air Supply Port One-Touch Fitting Size: Ø6, Application: Manifolds, Operating Pressure Range(MPa): 0.1~0.6, Operating Temperature Range(°C
Main Body Shape: Pipe Type, Additional Function: -, Ultimate Vacuum(kPa): -90, Air Consumption Flow Rate(l/min): 13, Vacuum Port Connecting Port Shape: One-Touch Couplings, Vacuum Port One-Touch Fitting Size: Ø6, Air Supply Port Connecting Shape: One-Touch Couplings, Air Supply Port One-Touch Fitting Size: Ø6, Application: Manifolds, Operating Pressure Range(MPa): 0.1~0.6, Operating Temperature
Main Body Shape: Pipe Type, Additional Function: Silencers, Ultimate Vacuum(kPa): -90, Air Consumption Flow Rate(l/min): 13, Vacuum Port Connecting Port Shape: One-Touch Couplings, Vacuum Port One-Touch Fitting Size: Ø6, Air Supply Port Connecting Shape: One-Touch Couplings, Air Supply Port One-Touch Fitting Size: Ø6, Application: Manifolds, Operating Pressure Range(MPa): 0.1~0.6, Operating
Lightweight, point-of-use ZH and ZU series vacuum generators combine design simplicity with high performance. Simply plug an air supply tube in one end, and vacuum is ready at the other end. The slim ZU generators are extra compact. The ZH and ZU immediate response may be quicker than central vacuum systems. Also, these generators are often smaller and lighter than the bulky vacuum lines
Lightweight, point-of-use ZH and ZU series vacuum generators combine design simplicity with high performance. Simply plug an air supply tube in one end, and vacuum is ready at the other end. The slim ZU generators are extra compact. The ZH and ZU immediate response may be quicker than central vacuum systems. Also, these generators are often smaller and lighter than the bulky vacuum lines
Nozzle Diameter: 07 (ø0.7mm), Vacuum Pressure: L (-48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A), SUP: 06 (One-touch Fitting ø6), VAC: 06 (One-touch Fitting ø6), EXH: 06 (One-touch Fitting ø6), Accessories: S (w/Standard Bracket, w/Silencer)
Nozzle Diameter: 07 (ø0.7mm), Vacuum Pressure: S (-90 kPa), SUP: 06 (One-touch Fitting ø6), VAC: 06 (One-touch Fitting ø6), EXH: 06 (One-touch Fitting ø6), Accessories: S (w/Standard Bracket, w/Silencer)
Nozzle Diameter: 05 (ø0.5mm), Vacuum Pressure: L (-48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A), SUP: 06 (One-touch Fitting ø6), VAC: 06 (One-touch Fitting ø6), EXH: 06 (One-touch Fitting ø6), Accessories: S (w/Standard Bracket, w/Silencer)
Main Body Shape: Pipe Type, Additional Function: Silencers, Ultimate Vacuum(kPa): -48, Air Consumption Flow Rate(l/min): 13, Vacuum Port Connecting Port Shape: One-Touch Couplings, Vacuum Port One-Touch Fitting Size: Ø6, Air Supply Port Connecting Shape: One-Touch Couplings, Air Supply Port One-Touch Fitting Size: Ø6, Application: Manifolds, Operating Pressure Range(MPa): 0.1~0.6, Operating
Main Body Shape: Pipe Type, Additional Function: Silencers, Ultimate Vacuum(kPa): -48, Air Consumption Flow Rate(l/min): 27, Vacuum Port Connecting Port Shape: One-Touch Couplings, Vacuum Port One-Touch Fitting Size: Ø6, Air Supply Port Connecting Shape: One-Touch Couplings, Air Supply Port One-Touch Fitting Size: Ø6, Application: Manifolds, Operating Pressure Range(MPa): 0.1~0.6, Operating
Main Body Shape: Pipe Type, Additional Function: Silencers, Ultimate Vacuum(kPa): -90, Air Consumption Flow Rate(l/min): 27, Vacuum Port Connecting Port Shape: One-Touch Couplings, Vacuum Port One-Touch Fitting Size: Ø6, Air Supply Port Connecting Shape: One-Touch Couplings, Air Supply Port One-Touch Fitting Size: Ø6, Application: Manifolds, Operating Pressure Range(MPa): 0.1~0.6, Operating
.: 06 (ø6), Actuator Type: 06 (Roller Plunger), Suffix: S (Hard Steel Roller)
Number of Ports: 3 Port, Piping Direction, Bar Height: Side Ported, Short, Tube O.D.: ø6, Actuator Type: Roller Plunger, Suffix: Hard Steel Roller, Indicator: -, Bracket: -
Lightweight, point-of-use ZH and ZU series vacuum generators combine design simplicity with high performance. Simply plug an air supply tube in one end, and vacuum is ready at the other end. The slim ZU generators are extra compact. The ZH and ZU i, Vacuum Ejector, Body Ported, VACUUM EJECTOR, 5 lb
CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 28 23.5 30 Piping adapter AC25, AC30 AF30, AR30, AW30 AL30, AFM30, AFD30, AWM30, AWD30 30 30 32 AC40 AF40, AR40, AW40 AL40, AFM40, AFD40 AWM40, AWD40 36 36 32 AC40-06, AF40-06, AR40-06, AW40-06 AL40-06, AFM40-06, AFD40-06 E500-06 44 40 32 3/4 E600-06 E600-10 3/4 1 AC50, AC55, AC60, AC50B
AW4000 AL4000, AFM4000, AFD4000 3/8 33 35 42.2 1/2 50 35 42.2 3/4 AC400-06 AF4000-06, AR4000-06, AW4000-06 AL4000-06, AFM4000-06, AFD4000-06 3/4 E50-06 36 44 46.2 To order piping adapter with bracket, the parts number as shown below.
/08)-(B5/B6/B8) ZPR-(04/06/08)-(A5/A6/A8) y t t Component Parts No.
YV Sizes 40-06, 50, and 60 have been added to the AC series. Sizes 40-06, 50, and 60 have been added to the AF, AR(K), and AL. The VHS40-06 and 50 have been added. Size 40-06 has been added to the AFM/AFD. Sizes 40-06 and 60 have been added to the AW(K). Made to order options have been added. Number of pages has been increased from 104 to 112.
3/4 E500-06 3/4 32 40 44 AC40-06, AF40-06, AR40-06, AW40-06 AL40-06, AFM40-06, AFD40-06 E600-06 3/4 35 48 53 AC50, AC55, AC60, AC50B, AC55B, AC60B AF50, AR50, AL50, AF60, AR60, AL60 E600-10 1 Notes) in model numbers indicates a thread type.