(Example) 40D-A3C-4 50D-A3C-5 63D-A3C-6 80D-A3C-8 100D-A3C-10 When other brackets are ordered separately, order by the above part numbers. Stainless steel mounting screw kit A set of stainless steel mounting screws (with set screws) described below is available and can be used as required by the operating environment.

(Example) 40D-A3C-4, 63D-A3C-6, 100D-A3C-10 50D-A3C-5, 80D-A3C-8 To order the mounting brackets separately, use the part number shown above.

Magnet: None, VAC Side Tube/Rod End Shape: Rod Piping/Male Thread, Bore Size: 32mm, Port Thread: NPT1/8, Bore 32, Stroke: 30mm, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard / Vacuum, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.11 to 0.7, Specification: Without built-in magnet,

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard / Vacuum, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.11 to 0.7, Specification: Without built-in magnet,

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard / Vacuum, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.11 to 0.7, Specification: Without built-in magnet,

Magnet: None, VAC Side Tube/Rod End Shape: Q (Rod Piping/Male Thread), Bore Size: 32mm, Port Thread: TN (NPT1/8, Bore 32), Stroke: 50mm

Magnet: None, VAC Side Tube/Rod End Shape: Q (Rod Piping/Male Thread), Bore Size: 32mm, Port Thread: TN (NPT1/8, Bore 32), Stroke: 25mm

Magnet: None, VAC Side Tube/Rod End Shape: Q (Rod Piping/Male Thread), Bore Size: 32mm, Port Thread: TN (NPT1/8, Bore 32), Stroke: 30mm

Magnet: None, VAC Side Tube/Rod End Shape: Q (Rod Piping/Male Thread), Bore Size: 32mm, Port Thread: TN (NPT1/8, Bore 32), Stroke: 10mm

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard / Vacuum, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.11 to 0.7, Specification: Without built-in magnet,

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard / Vacuum, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.11 to 0.7, Specification: Without built-in magnet,

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard / Vacuum, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.11 to 0.7, Specification: Without built-in magnet,

11L]: [21L]: [51L]: 10 to 100 L/min type (PF2A511) 20 to 200 L/min type (PF2A521) 50 to 500 L/min type (PF2A551) [10L]: [50L]: PF2W30 series PF2W33 series [11L]: 10 to 100 L/min type (PF2W511) 0.5 to 4 L/min type (PF2W504) [04L]: [20L]: [40L]: 2 to 16 L/min type (PF2W520) 5 to 40 L/min type (PF2W540) PF2D30 series 0.4 to 4 L/min type (PF2D504) 1.8 to 20 L/min type (PF2D520) [04d]: [20d]: [40d

PF2D20 series 0.4 to 1.8 to 4 L/min type (PF2D504) [04d]: [20d]: [40d]: 20 L/min type (PF2D520) 40 L/min type (PF2D540) 4 to Press the button. (continued) -22No.PF-OMH0003-F Selection of display mode Select the display of instantaneous flow or accumulated flow. Press the button to select. [d_1]: display instantaneous flow [d_2]: display accumulated flow Press the button.

MH*-OMC0028 PRODUCT NAME Parallel Type Air Gripper MODEL / Series / Product Number MHL2-10D* MHL2-16D* MHL2-20D* MHL2-25D* MHL2-32D* MHL2-40D* Contents 1. Safety Instructions 2. Product Specifications 3. Operating method or operation 3-1. Operating environment 3-2. Air supply 3-3. Lubrication 3-4. Mounting 3-5. Finger attachment 3-6. Selection 3-7.

Filter Regulator + Mist Separator ACG20D/30D/40D Options/Attachments Part No. Options/Attachments part no. ACG20D ACG30D ACG40D Model Description Pressure gauge Note 1) GB2-10AS GB3-10AS GB4-10AS 0 to 1.0 MPa 0 to 0.3 MPa Standard Optional N.C. N.O.

Filter Regulator + Mist Separator ACG20D/30D/40D Options/Attachments Part No. Options/Attachments part no. ACG20D ACG30D ACG40D Model Description Pressure gauge Note 1) 0 to 1.0 MPa 0 to 0.3 MPa Standard Optional N.C. N.O.

MLGC 40 50 63 80 100 MNB 40D-UA MNB 50D-UA CNG P 0.3 MPa MNB 63D-UA Piston rod assembly MNB 80D-UA MNB MNB100D-UA CNA 2. How to replace lock unit 1) Loosen the tie-rod nuts (4 pcs.) on the cylinder head cover side by using a hexagon wrench. For the applicable hexagon wrench, refer to the table below.

Bore size (mm) 40 50 63 80 100 Lock unit order number MNB 40D-UA MNB 50D-UA P0.3MPa Piston rod assembly P0.3MPa MNB 63D-UA MNB 80D-UA MNB100D-UA 2. Replacement of lock units. 1) Loosen the tie-rod nuts (4pcs.) on the cylinder head cover using a hexagon wrench. Refer to the table below for the applicable hexagon wrench.