SMC Corporation of America
Elite Part Number Search
Search Results "XLAV-40G-M9NA-5HZ"

Valve Type: Normally Closed, Bellows Seal, Flange Size: 40, Flange Type: KF (NW), Valve Direction: w/Indicator, Rear Flange Surface, Version: 2, Auto Switch: A90--Reed, AC Volt, Horizontal, 0.5M, Lead Wire: 3m, Number: 2pcs, Valve Open/Closed, Voltage: 24 VDC, Electrical Entry: L Type Plug Connector, Surge Suppressor: w/Light & Surge Voltage Suppressor, Non-polar Type, Non-standard Indicator

Valve Type: Normally Closed, Bellows Seal, Flange Size: 40, Flange Type: KF (NW), Valve Direction: w/Indicator, Rear Flange Surface, Version: 2, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire: 5m, Number: 2pcs, Valve Open/Closed, Voltage: 24 VDC, Electrical Entry: G [Grommet (Lead Wire Length 300mm)], Surge Suppressor: w/Light & Surge Voltage Suppressor, Non-standard

Valve Type: Normally Closed, Bellows Seal, Flange Size: 40, Flange Type: KF (NW), Valve Direction: w/Indicator, Rear Flange Surface, Version: 2, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire: 3m, Number: 2pcs, Valve Open/Closed, Voltage: 24 VDC, Electrical Entry: H [Grommet ( Lead Wire Length 600mm)], Surge Suppressor: -, Non-standard Indicator: -, Body Surface

Valve Type: Normally Closed, Bellows Seal, Flange Size: 40, Flange Type: KF (NW), Valve Direction: w/Indicator, Rear Flange Surface, Version: 2, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire: 5m, Number: 2pcs, Valve Open/Closed, Voltage: 24 VDC, Electrical Entry: L Type Plug Connector, Surge Suppressor: w/Light & Surge Voltage Suppressor, Non-standard Indicator

Valve Type: XLFV (Normally Closed, O-ring Seal), Flange Size: 40, Flange Type: KF (NW), Valve Direction: G (w/Indicator, Rear Flange Surface), Version: 2 (Refresh), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: A (2pcs, Valve Open/Closed), Voltage: 5 (24 VDC), Electrical Entry: H [Grommet ( Lead Wire Length

Valve Type: Normally Closed, O-ring Seal, Flange Size: 40, Flange Type: KF (NW), Valve Direction: w/Indicator, Rear Flange Surface, Version: Refresh, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: 2pcs, Valve Open/Closed, Voltage: 24 VDC, Electrical Entry: H [Grommet ( Lead Wire Length 600mm)], Surge Suppressor

Valve Type: XLAV (Normally Closed, Bellows Seal), Flange Size: 25, Flange Type: KF (NW), Valve Direction: F (w/Indicator, Left Flange Surface), Version: None, Auto Switch: w/o Auto Switch and w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Voltage: 5 (24 VDC), Electrical Entry: H [Grommet ( Lead Wire Length 600mm)], Surge Suppressor: Z (w/Light

Valve Type: XLAV (Normally Closed, Bellows Seal), Flange Size: 16, Flange Type: KF (NW), Valve Direction: G (w/Indicator, Rear Flange Surface), Version: None, Auto Switch: w/o Auto Switch and w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Voltage: 5 (24 VDC), Electrical Entry: H [Grommet ( Lead Wire Length 600mm)], Surge Suppressor: Z (w/Light

Valve Type: XLAV (Normally Closed, Bellows Seal), Flange Size: 25, Flange Type: KF (NW), Valve Direction: J (w/Indicator, Right Flange Surface), Version: None, Auto Switch: w/o Auto Switch and w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Voltage: 5 (24 VDC), Electrical Entry: H [Grommet ( Lead Wire Length 600mm)], Surge Suppressor: Z (w/Light

Valve Type: XLAV (Normally Closed, Bellows Seal), Flange Size: 50, Flange Type: KF (NW), Valve Direction: G (w/Indicator, Rear Flange Surface), Version: None, Auto Switch: w/o Auto Switch and w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Voltage: 5 (24 VDC), Electrical Entry: H [Grommet ( Lead Wire Length 600mm)], Surge Suppressor: Z (w/Light

Valve Type: XLAV (Normally Closed, Bellows Seal), Flange Size: 40, Flange Type: KF (NW), Valve Direction: F (w/Indicator, Left Flange Surface), Version: None, Auto Switch: w/o Auto Switch and w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Voltage: 5 (24 VDC), Electrical Entry: H [Grommet ( Lead Wire Length 600mm)], Surge Suppressor: Z (w/Light

Valve Type: XLAV (Normally Closed, Bellows Seal), Flange Size: 25, Flange Type: KF (NW), Valve Direction: G (w/Indicator, Rear Flange Surface), Version: None, Auto Switch: w/o Auto Switch and w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Voltage: 5 (24 VDC), Electrical Entry: H [Grommet ( Lead Wire Length 600mm)], Surge Suppressor: Z (w/Light

Valve Type: Normally Closed, Bellows Seal, Flange Size: 25, Flange Type: KF (NW), Valve Direction: w/Indicator, Left Flange Surface, Version: None, Auto Switch: w/o Auto Switch and w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Voltage: 24 VDC, Electrical Entry: H [Grommet ( Lead Wire Length 600mm)], Surge Suppressor: w/Light & Surge Voltage Suppressor

Valve Type: Normally Closed, Bellows Seal, Flange Size: 16, Flange Type: KF (NW), Valve Direction: w/Indicator, Rear Flange Surface, Version: None, Auto Switch: w/o Auto Switch and w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Voltage: 24 VDC, Electrical Entry: H [Grommet ( Lead Wire Length 600mm)], Surge Suppressor: w/Light & Surge Voltage Suppressor

Valve Type: Normally Closed, Bellows Seal, Flange Size: 25, Flange Type: KF (NW), Valve Direction: w/Indicator, Right Flange Surface, Version: None, Auto Switch: w/o Auto Switch and w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Voltage: 24 VDC, Electrical Entry: H [Grommet ( Lead Wire Length 600mm)], Surge Suppressor: w/Light & Surge Voltage Suppressor

Valve Type: Normally Closed, Bellows Seal, Flange Size: 50, Flange Type: KF (NW), Valve Direction: w/Indicator, Rear Flange Surface, Version: None, Auto Switch: w/o Auto Switch and w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Voltage: 24 VDC, Electrical Entry: H [Grommet ( Lead Wire Length 600mm)], Surge Suppressor: w/Light & Surge Voltage Suppressor

Valve Type: Normally Closed, Bellows Seal, Flange Size: 40, Flange Type: KF (NW), Valve Direction: w/Indicator, Left Flange Surface, Version: None, Auto Switch: w/o Auto Switch and w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Voltage: 24 VDC, Electrical Entry: H [Grommet ( Lead Wire Length 600mm)], Surge Suppressor: w/Light & Surge Voltage Suppressor

Valve Type: Normally Closed, Bellows Seal, Flange Size: 25, Flange Type: KF (NW), Valve Direction: w/Indicator, Rear Flange Surface, Version: None, Auto Switch: w/o Auto Switch and w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Voltage: 24 VDC, Electrical Entry: H [Grommet ( Lead Wire Length 600mm)], Surge Suppressor: w/Light & Surge Voltage Suppressor

-16-2 40 108 38 30 17 41 XLAV-25-2 50 121 48 40 26 46 XLAV-40-2 65 171 66 55 41 54.5 XLAV-50-2 70 185 79 75 52 61 XLAV-63-2 88 212 100 87 95 70 80.5 XLAV-80-2 90 257 117 114 110 83 90.5 Model K L M N S T XLAV-16-2 17.2 10.2 3.6 3.6 M5 M5 XLAV-25-2 21.4 10.2 3.6 3.6 M5 M5 XLAV-40-2 33.9 10.2 3.6 3.6 M5 M5 XLAV-50-2 38.2 10.2 3.6 3.6 M5 M5 XLAV-63-2 43.8 12 4 2 Rc1/8 M5 XLAV-80-2 59.8 12 4

A XLAV: Air operated, With solenoid valve J N M Port 1(P) K L Port 3(R) Solenoid valve [mm] Model J K L M N XLAV-16-2 41 18.5 8.5 2.7 3 XLAV-25-2 45.5 22.5 8.5 2.7 3 XLAV-40-2 54.5 35 8.5 2.7 3 XLAV-50-2 61 39.5 8.5 2.7 3 XLAV-63-2 80.5 44 12 4 2 XLAV-80-2 90.5 60 12 4 2 6 Aluminum High Vacuum Angle Valve Double Acting, Bellows Seal RoHS XLC Series How to Order q w e r t y u XLC 2 M9N 16