Initial Setting method 18 4.1 GSDML file and icons 18 4.2 GSDML file installation 18 4.3 Addition of JXCPH controller to PROFINET network 19 4.4 Registration of the device name of the JXCPH controller to be connected 20 4.5 Assign Device Name 20 5.
Specifications . 20 3.1 Specifications . 20 (1) Basic specifications of the product. . 20 (2) CC-Link communication . 21 3.2 Parts Description . 22 3.3 External Dimensions. 23 (1) Screw mounting (JXCM17#-#) . 23 (2) DIN rail mounting (JXCM18#-#) . 23 3.4 Mounting . 24 (1) Mounting . 24 1 - (2) Grounding . 24 3 Mounting location . 25 (4) Precautions for electric actuator compatible with battery-less
[%F.S.] 2.0 1.5 1.0 0.5 0.0 0 1 2 3 4 5 [s] [S] [MPa] [MPa] [MPa] [MPa] [ [ [ [ ] ] ] ] 2 69 No.LFE*-OMY0008 / / / / A B C 1 V 1.1 V 5 V 4 mA 4.4 mA 20 mA [L/min] LFE1 0.5 20 LFE2 2.5 100 LFE3 5 200 70 No.LFE*-OMY0008 2x )M12 () 1.6mm A B C D E F G H I J K L LFE13 3/8 90 73 40 23.5 56 83 89 24 6 1.6 96 87 LFE14 1/2 104 73 40 23.5 56 83 89 28 6 1.6 96 87 LFE26 3/4 105 78 50 29 67
Initial Setting 19 4.1 Setting of switch (IP address) 19 4.2 Hardware Configuration 20 4.3 Setting of EtherNet/IPTM using RSLogix5000TM 21 4.4 EtherNet/IP object 23 5.
Axis mode (mm/s) (mm) Selection (mm) (mm) 2) 2) (mm/s (mm/s (mm) 0 ABS 100 20.00 1000 1000 0 0 0 100 18.00 22.50 0.5 1 ABS 50 10.00 1000 1000 70 60 5 100 6.0 12.0 1.5 63 ABS 20 5.00 500 500 0 0 0 100 3.0 8.0 1.2 -41- () () (TB) No. Step No. 063 No. TB PLC 0 No.
The proof pressure is double the operating pressure range. -27No.LV50***-OMQ0004-F Analogue output Flow rate/Analogue output Output A B C Voltage output 1 V 1.1 V 5 V C Current output 4 mA 4.4 mA 20 mA Rated flow rate[L/min] B Model Minimum Maximum A LFE1 0.5 20 Flow rate 0 Minimum rated flow Maximum rated flow LFE2 2.5 100 LFE3 5 200 Out of range -28No.LV50***-OMQ0004-F Dimensions Note)
High temp. cut off alarm ERR12 Low temp. cut off alarm ERR13 Unused Output failure alarm ERR15 D2 23 22 21 20 Upper temperature limit alarm WRN Lower temperature limit alarm WRN Thermostat alarm ERR14 DC power supply failure alarm ERR11 D3 23 22 21 20 External sensor failure alarm ERR18 Internal sensor failure alarm ERR17 During Auto tuning or auto tuning warning ERR19 Flow switch alarm
High temp. cut off alarm ERR12 Low temp. cut off alarm ERR13 Unused Output failure alarm ERR15 D2 23 22 21 20 Upper temperature limit alarm WRN Lower temperature limit alarm WRN Thermostat alarm ERR14 DC power supply failure alarm ERR11 D3 23 22 21 20 External sensor failure alarm ERR18 Internal sensor failure alarm ERR17 During Auto tuning or auto tuning warning ERR19 Flow switch alarm
(PE) port of the solenoid valve is significantly restricted or blocked, the valve operation may become abnormal. 1/4 8 to 12 3/8 15 to 20 1/2 20 to 25 3/4 28 to 30 Mounting 1 36 to 38 1. Operation manual 1 1/4 40 to 42 1 1/2 48 to 50 2 48 to 50 Install the products and operate them only after reading the operation manual carefully and understanding its contents.
Warning Connection thread Proper tightening torque ( ( ( (N m) Rc1/8 3 to 5 Rc1/4 8 to12 Rc3/8 15 to 20 Rc1/2 20 to 25 Rc3/4 28 to 30 Rc1 36 to 38 Rc1 1/4 40 to 42 Rc1 1/2 48 to 50 Follow the procedure of the manufacturer when fittings other than SMC is used. 4. Piping Make P port piping so that supply air pressure does not become lower than operating pressure while operating.
Tightening Torque for Piping Caution Caution Connection Proper tightening Proper tightening torque (N m ) thread Rc 1/4 8 to12 Rc 3/8 15 to 20 Rc 1/2 20 to 25 Rc 3/4 28 to 30 Mounting Follow the procedure of the manufacture when fittings other than SMC is used. 5.
Note) Tighten within the tightening torque of 0.5 Nm 20%. Changing the entry direction The cable entry direction of a connector can be changed as desired (4 directions at 90 intervals), depending on the combination of a housing (4) and a terminal block (3).
DC coil 2% or less of the rated voltage AC coil 20% or less of the rated voltage 5. Not suitable for use as an emergency shutoff valve, etc. The valves presented in this catalog are not designed for safety applications (e.g. emergency shutoff valve). If the valves are used in such applications, additional safety measures should be adopted. 6.
Connector for DIN Terminal Note) Tighten within the tightening torque of 0.5 Nm 20%. Changing the entry direction The cable entry direction of a connector can be changed as desired (4 directions at 90 intervals), depending on the combination of a housing (4) and a terminal block (3). Description Part no.
ACl00V AC200V DC + DIN 7 VT317**-OMH0003-A DIN 1. 1) () 2) 3) 3a 4) 2. 1) 2 33f 3e Y 3f )0.5Nm15% a 3f 3d 2 3.5 b O 1.25mm 2 4 Y 1.25mm c 612mm 912 3. 1) ) 2) 3) )0.5Nm20% 904 DIN AC DC DC AC 8 VT317**-OMH0003-A N.C.N.O. 1. N.C./N.O.180 N.C. N.O. N.C.N.O. * N.C.N.O. N.C. N.O. N.C. N.O. 1.M4 2 1.4Nm 2.
Solenoid: No.3 Solenoid, Body Size: 9 (50A), Style: 0 (Energized Open/N.C.), Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 20 [2 (50A)], Thread: Rc, Voltage: 8 (48VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: S (Surge Suppressor)
Solenoid: No.3 Solenoid, Body Size: 9 (50A), Style: 0 (Energized Open/N.C.), Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 20 [2 (50A)], Thread: Rc, Voltage: 6 (12VDC), Lead Wire: G (Grommet), Surge Suppressor: S (Surge Suppressor)
Solenoid: No.3 Solenoid, Body Size: 50A, Style: Energized Open/N.C., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 20 [2 (50A)], Thread: Rc, Voltage: 220VAC 50/60HZ, Lead Wire: Grommet, Surge Suppressor: -
Solenoid: No.3 Solenoid, Body Size: 50A, Style: Energized Open/N.C., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 20 [2 (50A)], Thread: Rc, Voltage: 24VDC, Lead Wire: DIN Connector, Surge Suppressor: -
Solenoid: No.3 Solenoid, Body Size: 50A, Style: Energized Open/N.C., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 20 [2 (50A)], Thread: Rc, Voltage: 24VDC, Lead Wire: DIN Connector, Surge Suppressor: Light