/O.D. mm 5/8 6/9 6.5/10 8/12 8.5/12.5 11/16 Symbol M5 01 02 03 04 06 Symbol 23 04 06 08 10 12 16 Symbol 50 60 65 80 85 110 167 Series KK Flow Characteristics Air (0 to 1 MPa) Water (0 to 0.4 MPa) KK2 KK2 0.007 0.50 Series KK2 (KK2S-M5M + KK2P-M5M) Series KK2 (KK2S-M5M + KK2P-M5M) 0.45 0.006 0.40 0.005 0.35 Flow rate m3/min (ANR) Flow rate m3/min Flow rate m3/min 0.30 0.004 0.25 0.003 0.20

G 1/4 (ND7100), 1/4 NPT (ND7200). 06 High capacity. Stroke volume of actuator > 3 dm3. G 1/4 (ND7100), 1/4 NPT (ND7200). T 5. COMMUNICATION / INPUT SIGNAL RANGE ND7_HXT, ND7_HZT: II 3 G Ex nA IIC T6...T4 Gc II 3 D Ex tc IIIC T90 C Dc Ui 30 V, Ii 152 mA H 420 mA, HART communication. Supply voltage 30 V DC.

BA 32 BA 04 BA 05 BA 06 BA 08 BA 10 BA 01 BA 02 BM1 01 BM1 02 BM1 32 BM1 04 BM1 05 BM1 06 The following stainless steel mounting screw kits (including set screws) are available for use depending on the operating environment. (Order the mounting band separately, as it is not included.)

Take measures to prevent freezing, since moisture in circuits will be frozen under -5C, and this may cause damage to seals and lead to malfunction. Refer to the "Air Cleaning Equipment" catalog for details on compressed air quality. This will cause damage to the seals. 23 Series MNB Auto Switch Precautions 1 Be sure to read before handling. Design & Selection Warning 7.

Low temperature operation Avoid ambient temperatures outside the range of 10 to 60C (5C minimum for rubber seals). At low temperatures, appropriate measures should be taken to avoid solidification or freezing of drainage and moisture, etc. 4. Operation for air blowing When using solenoid valves for air blowing, an external pilot type or direct solenoid operated type should be used.

Action Double acting Proof pressure 1.5 MPa Maximum operating pressure 1.0 MPa Minimum operating pressure 0.08 MPa 0.2 MPa Piston speed 50 to 500 mm/sec* 15 to 300 mm/sec* Ambient and fluid temperature Without auto switch: 10C to 70C With auto switch: 10C to 60C (No freezing) 5C to 60C Cushion Air cushion None Stroke length tolerance Up to 250: +1.0 0 , 251 to 1000: +1.4 0 , 1001 to 1500:

VR VR51 VR51 Supply pressure and piping length at the outlet side VHK 50 Outlet piping length (m) VH 40 VHS 30 20 VHS 10 0 0 0.2 0.4 0.6 0.8 1 Supply pressure (MPa) When the piping length is long and capacity is large due to a branch, install a speed controller (AS2051F-06, AS3001F-06, etc.) close to the A port of the VR51 in accordance with the below figure.

(mm) 02 04 06 08 10 13 16 20 25 32 40 50 2 4 6 8 10 13 16 20 25 32 40 50 Pad type 02 04 06 08 10 13 16 20 25 32 40 50 2 4 6 8 10 13 16 20 25 32 40 50 Pressure gauge position Thread dia.

Take measures to prevent freezing, since moisture in circuits will be frozen under 5C, and this may cause damage to seals and lead to malfunction. Refer to the "Air Cleaning Equipment" catalog for details on compressed air quality. Caution 1. Drain flushing. Remove condensate from air filters regularly. (Refer to specifications.)

Water vapors in the circuit to be measured may freeze if the temperature goes below 5C and could damage the O ring or cause the switch to malfunction. The installation of an air dryer is recommended to remove any kind of moisture.

Normally closed Normally open VNA01 VNA02 VNA03 Valve Double acting Pressure range Lubrication Temperature Style External pilot air 5C to 50C(Air operated: 60C) Note 1) No freezing Note 2) Lubrication is not allowed in case of seal material EPR.

7.24 (184) 7.47 (200) (26) 9.13 (232) 9.76 \244) 1039 ( 4 ) '11'o2 (280) 11.66 (2e6)12.2a (32) 12.91 (328) t3 0.63 o6) 1.26 (32) 1.89 (4s) (64) 3.15 (80) 3.78 (e6) 4.41 1112) 5.04 (128) (i44) 6.30 (160) 6.93 (176) /.5tt (ie2) 8.19 (208) La2 (224)9.45 (240) 1008 (2s6) 10.71 1272) 11.34 \28) 11.97 (304) L, 0.31 (8) 0.94 (24) 1.57 (40) 2.20 (56.) 2.43 (72) 3.46 (88) 4.0s 004) 4-72 (120) c.5c

In addition, the cooling water cannot theoretically be cooled to a temperature any lower than 5C above the wet-bulb temperature of the outside air.

If the fluid temperature is 5C or less, the moisture in the circuit could freeze, causing damage to the seals or equipment malfunction. Therefore, take appropriate measures to prevent freezing. For compressed air quality, refer to the SMC Best Pneumatics No. 6 catalog. 5.

Tightening Torque for Piping VK300 series can be used down to -5C. VK3000 series can be used down to -10C. Connection thread Proper tightening torque (Nm) Rc1/8 3~ 5 5 VK300**-OMH0002-C VK300/3000 Series Precautions for 3/5 Port Solenoid Valve 3 Be sure to read before handling. Piping Air Supply 4. Piping to products 1.

7.24 (184) 7.47 (200) (26) 9.13 (232) 9.76 \244) 1039 ( 4 ) '11'o2 (280) 11.66 (2e6)12.2a (32) 12.91 (328) t3 0.63 o6) 1.26 (32) 1.89 (4s) (64) 3.15 (80) 3.78 (e6) 4.41 1112) 5.04 (128) (i44) 6.30 (160) 6.93 (176) /.5tt (ie2) 8.19 (208) La2 (224)9.45 (240) 1008 (2s6) 10.71 1272) 11.34 \28) 11.97 (304) L, 0.31 (8) 0.94 (24) 1.57 (40) 2.20 (56.) 2.43 (72) 3.46 (88) 4.0s 004) 4-72 (120) c.5c

(Inlet air pressure: 0.7 MPa, Inlet air temperature: 20C) HA How to Order AT ID 20 02 0 ID AMG ID400 Option B Bracket Z Adsorbent for low dew point Basic size AFF 20 30 40 60 Port size AM ID200 02 B 04 06 1 4 B 1 2 B 3 4 Nil Rc Thread type Misc.

(Inlet air pressure: 0.7 MPa, Inlet air temperature: 20C) HA How to Order AT ID 20 02 0 ID AMG ID400 Option B Bracket Z Adsorbent for low dew point Basic size AFF 20 30 40 60 Port size AM ID200 02 B 04 06 1 4 B 1 2 B 3 4 Nil Rc Thread type Misc.

Temperature range which can be set with the Thermo-cooler 5C to 35C Example) Customer requirement: 20C 3. What kind of the circulating fluids will be used? Relationship between circulating fluid (which can be used with the Thermo-cooler) and ambient temperature Aqueous solution of 15% ethylene glycol Clear water 5C 5C 40C Example) Customer requirement: Clear water 4.

5C 100 100 Ambient temperature Ambient temperature Ambient temperature Ambient temperature 0 0 10 15 25 20 30 40 35 10 15 25 20 30 40 35 Circulating fluid temperature [C] Circulating fluid temperature [C] HRR010-W-20 [50 Hz] [60 Hz] 400 400 35C Heating capacity [W] Heating capacity [W] 35C 300 300 25C 25C 200 200 5C 5C 100 100 Facility water temperature Facility water temperature Facility