If the alarm is still generated when the power is reapplied, please contact SMC. (2) Please check if the power supply capacity is insufficient or not. 55 -
/code1-051 15ms IN* 30ms DRIVE /P25 1) No. RESET 15ms 3 30ms /P25 1) No. No. 4 PLC No. 15ms 1IN* 30ms DRIVE /P25 1) / No. OUT 15ms 2 30msmsec /P25 1) No. OUT -42- No. No. PLC /P25 1) No. OUT 3 INP INP LEFS 0.5 LEFB 1 4 1INP BUSYOFF 5 6 7 () 1 / EMG SVREOFF 2 /CN1 BK RLS DC24V(+) /P34 5.6 8 1 , , EMG SYREOFF /P911 2.1.
E 60 -
VT Port size Type of actuation VP342 VP344 VP542 VP544 VP742 VP744 Port size Rc Without sub-plate Nil VP Symbol Common use to normally closed and normally open (Pilot) 4 VG Body type 01 1 8 02 1 4 03 3 8 1 2 04 Body ported 2 Base mounted 4 VP Valve option VP344, VP544, or VP744 only.
Drive is ON when SVRE is OFF (01-098) C Input RESET
Base Mounted Wiring: 01 (Plug-in, Insert Plug w/Lead Wire), Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 5 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 02 (1/4)
Base Mounted Wiring: 01T (Plug-in w/Terminal Block), Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 5 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 01 (1/8)
Base Mounted Wiring: 01T (Plug-in w/Terminal Block), Pilot Type: Internal Pilot or None, Junction Cover: 1 (One-piece Junction Cover), Stations: 5 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 01 (1/8)
Base Mounted Wiring: 10 (Non Plug-in Individual Lead Wire Entry), Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 5 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 01 (1/8)
Base Mounted Wiring: 01FD (Plug-in w/D-sub Connector on D Side), Pilot Type: Internal Pilot or None, Junction Cover: 1 (One-piece Junction Cover), Stations: 5 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 01 (1/8)
Base Mounted Wiring: 01 (Plug-in, Insert Plug w/Lead Wire), Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 5 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 02 (1/4), Thread: N (NPT)
Base Mounted Wiring: 01 (Plug-in, Insert Plug w/Lead Wire), Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 5 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 02 (1/4), Thread: T (NPTF)
Base Mounted Wiring: Plug-in, Insert Plug w/Lead Wire, Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 5 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 1/4, Thread: -, Control Unit: -, Voltage of Air Release Valve: -, Q: -
Base Mounted Wiring: Plug-in w/Terminal Block, Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 5 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 1/8, Thread: -, Control Unit: -, Voltage of Air Release Valve: -, Q: -
Base Mounted Wiring: Plug-in w/Terminal Block, Pilot Type: Internal Pilot or None, Junction Cover: One-piece Junction Cover, Stations: 5 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 1/8, Thread: -, Control Unit: -, Voltage of Air Release Valve: -, Q: -
Base Mounted Wiring: Non Plug-in Individual Lead Wire Entry, Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 5 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 1/8, Thread: -, Control Unit: -, Voltage of Air Release Valve: -, Q: -
Base Mounted Wiring: Plug-in w/D-sub Connector on D Side, Pilot Type: Internal Pilot or None, Junction Cover: One-piece Junction Cover, Stations: 5 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 1/8, Thread: -, Control Unit: -, Voltage of Air Release Valve: -, Q: -
Base Mounted Wiring: Plug-in, Insert Plug w/Lead Wire, Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 5 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 1/4, Thread: NPT, Control Unit: -, Voltage of Air Release Valve: -, Q: -
Base Mounted Wiring: Plug-in, Insert Plug w/Lead Wire, Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 5 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 1/4, Thread: NPTF, Control Unit: -, Voltage of Air Release Valve: -, Q: -
VV5FS2 MANIFOLD, WITH BLOCKING PLATES, 4/5 PORT SOLENOID VALVE, I50, 800 lb