Base Mounted Wiring: 01T (Plug-in w/Terminal Block), Stations: 04 Stations, Passage: 1 (P: Common, EA,EB: Common, Port A,B: Side), Port Size: 04 (1/2), Thread: T (NPTF)
Base Mounted Wiring: 01T (Plug-in w/Terminal Block), Stations: 04 Stations, Passage: 2 (P: Common, EA,EB: Common, Port A,B: Bottom), Port Size: 04 (1/2), Thread: T (NPTF)
ISG121-030 ISG221-030 Stainless steel 316 None 0.02 to 0.35 Cable gland ISA2 ISG121-031 ISG221-031 Stainless steel 316 Yes 0.02 to 0.45 Type A IS ISG130-030 ISG230-030 Brass, Phosphor bronze None 0.03 to 0.4 20a ISG130-031 ISG230-031 Brass, Phosphor bronze Yes 0.03 to 0.6 20b ZSM 0.1 to 1.0 1.5 0.02 ISG131-030 ISG231-030 Stainless steel 316 None 0.03 to 0.4 20c PF2 ISG131-031 ISG231-031
Base Mounted Wiring: 01T (Plug-in w/Terminal Block), Stations: 3 Stations, Passage: 1 (P: Common, EA,EB: Common, Port A,B: Side), Port Size: 04 (1/2)
Base Mounted Wiring: 01T (Plug-in w/Terminal Block), Stations: 3 Stations, Passage: 1 (P: Common, EA,EB: Common, Port A,B: Side), Port Size: 04 (1/2)
Base Mounted Wiring: 01T (Plug-in w/Terminal Block), Stations: 3 Stations, Passage: 1 (P: Common, EA,EB: Common, Port A,B: Side), Port Size: 04 (1/2)
Base Mounted Wiring: Plug-in w/Terminal Block, Stations: 3 Stations, Passage: P: Common, EA,EB: Common, Port A,B: Side, Port Size: 1/2, Thread: -, Control Unit: -, Release Valve Rated Voltage: -
Base Mounted Wiring: Plug-in w/Terminal Block, Stations: 3 Stations, Passage: P: Common, EA,EB: Common, Port A,B: Side, Port Size: 1/2, Thread: -
Base Mounted Wiring: Plug-in w/Terminal Block, Stations: 3 Stations, Passage: P: Common, EA,EB: Common, Port A,B: Side, Port Size: 1/2, Thread: -, Control Unit: -, Voltage: -
For 3-position exhaust center valve or single acting cylinder, take appropriate measures to prevent malfunction by using it with an individual EXH Spacer assembly (VVFS5000-R-04-1,2). 5. Holding pressure (including vacuum) Since the valves are subject to air leakage, they cannot be used for applications such as holding pressure (including vacuum) in a pressure vessel. 6.
Caution Caution Type 01T with Terminal Block Remove junction cover of manifold, exposing terminal block attached to the manifold block. Lead wires from solenoid valve are connected with the terminals on upper side of terminal block.
Base Mounted Wiring: 01T (Plug-in w/Terminal Block), Stations: 2 Stations, Passage: 1 (P: Common, EA,EB: Common, Port A,B: Side), Port Size: 04 (1/2), Thread: N (NPT)
Base Mounted Wiring: 01T (Plug-in w/Terminal Block), Stations: 2 Stations, Passage: 1 (P: Common, EA,EB: Common, Port A,B: Side), Port Size: 04 (1/2)
Base Mounted Wiring: 01T (Plug-in w/Terminal Block), Stations: 5 Stations, Passage: 1 (P: Common, EA,EB: Common, Port A,B: Side), Port Size: 04 (1/2)
Base Mounted Wiring: 01T (Plug-in w/Terminal Block), Stations: 10 Stations, Passage: 1 (P: Common, EA,EB: Common, Port A,B: Side), Port Size: 04 (1/2)
Base Mounted Wiring: 01T (Plug-in w/Terminal Block), Stations: 7 Stations, Passage: 1 (P: Common, EA,EB: Common, Port A,B: Side), Port Size: 04 (1/2)