Base Mounted Wiring: 01CD (Base Mounted Plug-in w/Multi-connector on D Side), Stations: 06 Stations, Passage: 1 (P: Common, EA,EB: Common, Port A,B: Side), Port Size: 04 (1/2), Thread: N (NPT)
Base Mounted Wiring: 01T (Plug-in w/Terminal Block), Stations: 06 Stations, Passage: 1 (P: Common, EA,EB: Common, Port A,B: Side), Port Size: 04 (1/2), Thread: N (NPT)
Base Mounted Wiring: 10 (Non Plug-in Individual Lead Wire Entry), Stations: 06 Stations, Passage: 1 (P: Common, EA,EB: Common, Port A,B: Side), Port Size: 06 (3/4)
Base Mounted Wiring: 01FD (Plug-in w/D-sub Connector on D Side), Stations: 06 Stations, Passage: 1 (P: Common, EA,EB: Common, Port A,B: Side), Port Size: 04 (1/2)
Base Mounted Wiring: 01T (Plug-in w/Terminal Block), Stations: 06 Stations, Passage: 1 (P: Common, EA,EB: Common, Port A,B: Side), Port Size: 06 (3/4), Thread: T (NPTF)
Base Mounted Wiring: 01CD (Base Mounted Plug-in w/Multi-connector on D Side), Stations: 06 Stations, Passage: 1 (P: Common, EA,EB: Common, Port A,B: Side), Port Size: 06 (3/4), Thread: T (NPTF)
Base Mounted Wiring: 10 (Non Plug-in Individual Lead Wire Entry), Stations: 06 Stations, Passage: 1 (P: Common, EA,EB: Common, Port A,B: Side), Port Size: 04 (1/2), Thread: N (NPT)
(Refer to the table below) U D U D Cylinder port size Kit designation/Electrical entry/Cable length 3/8 NPTF 1/2 NPTF Bottom ported 1/2 NPTF Rc3/8 Rc1/2 Bottom ported Rc1/2 Mixed sizes Note) 03T 04T BT 03 04 B CM F L Kit (D sub connector kit) Kit (Lead wire kit) Note) Indicate on a manifold specification sheet in case of mixed sizes.
(Refer to the table below) U D U D Cylinder port size Kit designation/Electrical entry/Cable length 3/8 NPTF 1/2 NPTF Bottom ported 1/2 NPTF Rc3/8 Rc1/2 Bottom ported Rc1/2 Mixed sizes Note) 03T 04T BT 03 04 B CM F L Kit (D sub connector kit) Kit (Lead wire kit) Note) Indicate on a manifold specification sheet in case of mixed sizes.
Dimensions L6 Universal type D4 H D1 Applicable tubing O.D. d (Hexagon width across flats) (Hexagon width across flats) M1 L3 A L5 L4 D3 L1 L2 D2 T Metric Size Inch Size A A D1 d T H D2 D3 D4 L1 L2 L3 L4 L5 L6 M1 d T H D1 D2 D3 D4 L1 L2 L3 L4 L5 L6 M1 Model Model AS131F-M5-23T AS131F-U10/32-01T 1/8" 8.4 3.2 8.4 19.8 19.8 12.7 17.5 28.7 17.5 28.7 12.7 AS131F-M5-04T AS131F-U10/32-03T 5/32"
8", 1/2" are made of brass (Electroless nickel plated). 15-9-95 5 Dimensions L5 Elbow type D3 H Applicable tubing O.D. d (Hexagon width across flats) L4 L3 A D1 M1 L1 L2 D2 T Metric Size Inch Size d T H D2 D3 L1 L2 L3 L4 L5 A M1 d T H D1 D2 D3 L1 L2 L3 L4 L5 A M1 D1 Model Model AS121F-M5-23T AS121F-U10/32-01T 1/8" 8.4 17.3 22.1 12.3 3.2 8.4 5/32" 9.3 12.7 17.3 22.1 12.3 12.7 AS121F-M5-04T
SMC Pneumatics, Inc. 5 Series ASIII1F-T Dimensions (mm) 1in=25.4mm L5 D3 Elbow type H (width across flats) Applicable tubing O.D. d A L4 D1 L3 M1 D2 T L1 L2 Metric sizes Inch sizes d T H D1 D2 D3 L1 L2 L3 L4 L5 A M1 Model A D1 Model T H D2 D3 L1 L2 L3 L4 L5 M1 d AS121F-M5-23T AS121F-U10/32-01T 1/8" 8.4 17.3 22.1 12.3 3.2 8.4 5/32" 9.3 12.7 17.3 22.1 12.3 12.7 AS121F-U10/32-03T AS121F-M5-04T
(When operation is commanded through PLC, this alarm will be generated depending on the signal interval and the holding time of signals) Alarm _Comment _061 (01-061)
(When operation is commanded through PLC, this alarm will be generated depending on the signal interval and the holding time of signals) Alarm _Comment _061 (01-061)
(When operation is commanded through PLC, this alarm will be generated depending on the signal interval and the holding time of signals)
(When operation is commanded through PLC, this alarm will be generated depending on the input signal interval and the holding time of signals)
B RESET >+JOG (01-052) >+B RESET 65 - 112 12 0 2 3 4 5 6 7 Alarm _Comment _058 (01-058) 3A B RESET No.base PLC <> 1 1ABS 2INC 2PLC 2 14.2[2] (P.54) Alarm _Comment _061 (01-061) 3D B RESET <>+ <>+Alarm _Comment _062 (01-062) 3E B RESET <> (01-096) C RESET <> (01-097) <> C RESET <> <>OFF JOG OFF (01-098) OFF DRV C RESET <>ON SVRE ON DRIVE ON (01-099) <> SET OFF
(PLC ) Alarm _Comment _061 (01-061) <> (1) ()1(ABS)2(INC) (2)PLC 15ms(30ms) 13.2[2](P.53) 3D B RESET (+)(-) Alarm _Comment _062 (01-062) (+)(-) 3E B RESET <> (01-096) C RESET <> -64- (01-097) <> C RESET <> <>OFF JOG OFF (01-098) OFF DRV C RESET <>ON (SVRE ON) DRIVE ON (01-099) <> SET OFF DRV C RESET <> <>12 (01-103) C RESET 1 [] A [a ] 2 [SW] [] A [a ] <> <>
Electric circuit diagram 5Electric circuit diagram HAA7-061 HAA7-062 HAA15-101 HAA15-103 HAA22-143 HAA37-143 HAA Series 8 5. Electric circuit diagram ATX-OM-F004E Air-Cooled Aftercooler 6. Installation 6.
EX) Base: 6 stations, common EXH, A & B port Rc 1/2 VVPA450-061-04 1 pc. VPA4154-00 3 pcs. VPA4254-00 2 pcs. XT038N-4A 1 pc.