SY Type 40/41 (Bottom ported) How to Order Applicable solenoid valve VZ514VZ514MVZ524VZ524MApplicable blanking plate assembly DXT201-15-4A VV3Z5 40 05 2 01 SYJ R port R port P/R port thread type Manifold VK Stations 40 41 Type 40 Type 41 P port 02 2 stations Nil Rc VZ 01 1/8 A port side Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650
When either 0002H or 0003H is selected for the Speed Unit (parameter 41), set the Speed Base Unit (parameter 42) to a number between -3 and 0. 5. When 0004H is selected for the Speed Unit (parameter 41), set the Speed Base Unit (parameter 42) to 0. 8-130 8 MECHATROLINK-III Commands Parameter Name Setting Units Factory Enabled Size Category No.
M5 x 0.8 Type 41 Applicable solenoid valve SYJ314SYJ314MSYJ324SYJ324MHow to Order SS3YJ3 41 05 M3 Type 41 Type S41 Pilot valve is on the A port side. ( ) Valve mounting direction Stations 02 2 stations Pilot valve is opposite the A port side. Applicable blanking plate assembly SYJ300-10-2A Nil R port : : A A M5 x 0.8 R port 20 20 stations Pilot valve is on the A port side.
71 68 104 1/2 22 45 90 41 11 17 36 22.5 23 M5 8 26 84 48 74.5 103 74.5 70 107 1/4, 3/8 VCS41 30 50 94 41 13.5 17 36 25 23 M5 8 26 88 48 78.5 103 78.5 70 111.5 1/2 35 60 102 41 17.5 17 36 30 28.2 M5 8 26 96 48 86.5 103 86.5 70 119 3/4 342 Series VCS Direct Operated 2 Port Solenoid Valve For Steam How to Order Manifold How to Order Manifold Assembly VV2C S D 2 02 01 Enter the mounting valve
KFG2H0425-01 KFG2H0425-02 KFG2H0403-01 KFG2H0403-02 KFG2H0604-01 KFG2H0604-02 KFG2H0806-01 KFG2H0806-02 KFG2H0806-03 KFG2H1075-02 KFG2H1075-03 KFG2H1075-04 KFG2H1008-02 KFG2H1008-03 KFG2H1008-04 KFG2H1209-02 KFG2H1209-03 KFG2H1209-04 KFG2H1210-02 KFG2H1210-03 KFG2H1210-04 KFG2H1613-03 KFG2H1613-04 8 14 8 14 10 16 18 24 36 34 41 67 33 40 66 33 40 66 30 38 63 51 67 19.4 23.8 19.4 23.8 20.9
DIN terminal Closed center: VFR2310Exhaust center: VFR2410Pressure center: VFR2510L plug connector Closed center: VFR2310-LExhaust center: VFR2410-LPressure center: VFR2510-LM plug connector Closed center: VFR2310-MExhaust center: VFR2410-MPressure center: VFR2510-M01 02 01 02 01 02 01 02 01 02 01 02 01 02 D Y 01 02 D Y 01 02 D Y Applicable cable O.D. 6 to 8 [4.5 to 7] Light/Surge voltage
Type 42 Type How to Order Manifold How to Order Valve Manifold Assembly Ordering example Type 41 (Compact type) 41 SS5X 05 5 C8 Double solenoid (24 VDC) 1 2 3Stations SX3240-5G (2 set) Series Stations Blanking plate assembly 02 3 SX3000 5 SX5000 2 stations SY3000-26-2A (1 set) 20 20 stations A/B port size Thread piping Thread type Single solenoid (24 VDC) Applicable series Nil Symbol Port
M5 x 0.8 Type 41 Applicable solenoid valve SYJ314SYJ314MSYJ324SYJ324MHow to Order SS3YJ3 41 05 M3 Type 41 Type S41 Pilot valve is on the A port side. ( ) Valve mounting direction Stations 02 2 stations Pilot valve is opposite the A port side. Applicable blanking plate assembly SYJ300-10-2A Nil R port : : A A M5 x 0.8 R port 20 20 stations Pilot valve is on the A port side.
R Port Rc (PT)1/8 40/41 Type How to Order SS3YJ7-40 -05 --01 Applicable solenoid valve SYJ714-l SYJ714M-l SYJ724-l SYJ724M-l R Port Rc (PT)1/8 R Port Rc (PT)1/4 Valve model P Port Rc (PT)1/8 01 Rc (PT)1/8 A port side P Port Rc (PT)1/4 Stations 40 Type 40 Applicable blank plate ass'y SYJ700-10-2A 2 stations 02 41 Type 41 .. ..
(Pad diameter: 20 mm or less) ZP T 02 U N A5 From p. 33 p. 115 p. 117 From p. 121 With adapter ZP T 02 U N J 6 B3 A8 From p. 43 p. 116 p. 118 From p. 124 With buffer q w e r t y u i Flat type q Vacuum inlet direction w Pad diameter t Buffer stroke 02 2 16 16 04 4 20 20 06 6 25 25 08 8 32 32 10 10 40 40 13 13 50 50 e Material Nil Pad unit T Vertical R Lateral (With One-touch fitting) Y Lateral
pressure check valve (-B) SSQ2000-BP Built-in silencer (-S) P. 100 P. 99 P. 101 P. 103 C8 L8 Terminal number D-sub connector SOL.
Material ZQ Series ZPY Without buffer ZPY U N 02 N4 A5 ZF ZP Mounting thread (Refer to Table (2) for applications.) Pad diameter (mm) 02 04 2 4 ZCU Vacuum entry port (Refer to Table (2) for applications.) 06 6 AMJ 08 8 10 10 Misc. 13 13 Table (2) Vacuum Entry/Mounting Thread Diameter 16 16 Thread dia.
36.5 13.5 15 32 25 23 M5 24 59 46 57 60 54.5 48.5 101 57 68 1/2 22 45 89 41 11 17 36 22.5 23 M5 26 64.5 48 62.5 62 60 50.5 103 62.5 70 1/4, 3/8 VCW41 30 50 93.5 41 13.5 17 36 25 23 M5 26 66.5 48 64.5 62 62 50.5 103 64.5 70 1/2 35 60 101 41 17.5 17 36 30 28.2 M5 26 70 48 68 62 65.5 50.5 103 68 70 3/4 4 Direct Operated 2Port for Water Series VCW Dimensions (N.O.)
36.5 13.5 15 32 25 23 M5 24 59 46 57 60 54.5 48.5 101 57 68 1/2 22 45 89 41 11 17 36 22.5 23 M5 26 64.5 48 62.5 62 60 50.5 103 62.5 70 1/4, 3/8 VCW41 30 50 93.5 41 13.5 17 36 25 23 M5 26 66.5 48 64.5 62 62 50.5 103 64.5 70 1/2 35 60 101 41 17.5 17 36 30 28.2 M5 26 70 48 68 62 65.5 50.5 103 68 70 3/4 4.5-6 Direct Operated 2Port for Water Series VCW Dimensions (N.O.)
36.5 13.5 15 32 25 23 M5 24 59 46 57 60 54.5 48.5 101 57 68 1/2 22 45 89 41 11 17 36 22.5 23 M5 26 64.5 48 62.5 62 60 50.5 103 62.5 70 1/4, 3/8 VCW41 30 50 93.5 41 13.5 17 36 25 23 M5 26 66.5 48 64.5 62 62 50.5 103 64.5 70 1/2 35 60 101 41 17.5 17 36 30 28.2 M5 26 70 48 68 62 65.5 50.5 103 68 70 3/4 4 Direct Operated 2Port for Water Series VCW Dimensions (N.O.)
KQ2 KFG2H0425-01 KFG2H0425-02 KFG2H0403-01 KFG2H0403-02 KFG2H0604-01 KFG2H0604-02 KFG2H0806-01 KFG2H0806-02 KFG2H0806-03 KFG2H1075-02 KFG2H1075-03 KFG2H1075-04 KFG2H1008-02 KFG2H1008-03 KFG2H1008-04 KFG2H1209-02 KFG2H1209-03 KFG2H1209-04 KFG2H1210-02 KFG2H1210-03 KFG2H1210-04 KFG2H1613-03 KFG2H1613-04 1/8 1/4 1/8 1/4 1/8 1/4 1/8 1/4 3/8 1/4 3/8 1/2 1/4 3/8 1/2 1/4 3/8 1/2 1/4 3/8 1/2 3/8
Applicable individual EXH spacer assembly 02 2 stations Nil F N T Rc G NPT NPTF : : R port 1/8 Refer to page 330. 20 20 stations A, B port M5 x 0.8 M5 M5 x 0.8 A, B port size CE-compliant Nil Q CE-compliant How to Order Type 41 (5 port/Base mounted) M5 SS5YJ5 41 05 10 Stations Clean series 02 2 stations P, R port thread type CE-compliant -+ -+ : : Nil Q CE-compliant R port 1/8 R P Nil F
Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: 03-5207-8249 Fax: 03-5298-5362 URL http://www.smcworld.com 2008 SMC Corporation All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 1st printing KZ printing MQ 13500DN Printed in Japan.
-www.stevenengineering.com 20 20 stations R port 1/8 Applicable individual EXH spacer assembly A, B port M5 x 0.8 M5 M5 x 0.8 A, B port size Applicable individual SUP spacer assembly ARBYJ5000-00-P How to Order Type 41 (5 Port/Base mounted) SS5YJ5 41 05 M5 Stations 02 2 stations P, R port thread type -+ -+ R port 1/8 : : R P Nil F N T Rc G NPT NPTF 20 20 stations A, B port M5 x 0.8 M5 M5
Rc N NPT VQZ T NPTF F G SQ In the case of alone Sub-plate Terminal block Port size VFS 02 PW VQ2000 1/4 02 VFR Dimensions VQ7 4 89.4 (43.8) 2 x 4.5 (Mounting hole) 10.5 (A port) 10.5 (B port) Manual override Indicator light VQ210 0 1-1-02 37 5 45 121 <127.9> 22.4 15.5 77.2 Clamp screw M5 x 0.8 External pilot port 72.7 <76.7> 70.7 3 R2 R1 5 X 12 P 1 (A, B port) 25 25 25 20 15.4 12 2.5 5 14.5