BRACKET FOR VR2110, CHECK VALVE
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period.Transmitter-relay valve, North American threads, Fluid: air, Operating pressure: 0 to 1.0MPa, Effective area (Cv): 7mm (0.38), Port size: NPT 1/8, VALVE, RELAY, SGL PORT, VALVE, VR CHECK VALVE, CI, VR BODY PT 1/8NPT, .66000 lb,
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period.3 port check valve, Max. operating pressure: 1.0MPa, Ambient and fluid temp: -5 to 60C, Effective area (Cv): 0.38 to 0.81, SHUTTLE VALVE W/O FITTING, VALVE, VR CHECK VALVE, C7, VR BODY PT 1/8NPT, .06708 lb
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period.Transmitter-relay valve, metric threads, Fluid: air, Operating pressure: 0 to 1.0MPa, Effective area (Cv): 7mm² (0.38), Port size: Rc (PT) 1/8, VALVE, RELAY,DBL PORT, CHECK VALVE, J87, 0.3 lb
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period.Transmitter-relay valve, metric threads, Fluid: air, Operating pressure: 0 to 1.0MPa, Effective area (Cv): 7mm² (0.38), Port size: Rc (PT) 1/8, RELAY VALVE DBL, BOTTOM PIPING, CHECK VALVE, 0.3 lb
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period.Transmitter-relay valve, metric threads, Fluid: air, Operating pressure: 0 to 1.0MPa, Effective area (Cv): 7mm² (0.38), Port size: Rc (PT) 1/8, VALVE, RELAY, CHECK VALVE, J87, 0.35 lb
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period. 3 port check valve; Max. operating pressure: 1.0MPa; Ambient and fluid temp: -5° to 60°C; Effective area (Cv): 0.38 to 0.81
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period. Maximum operating pressure: 1MPa (145 psi); Minimum operating pressure: 0.05MPa (7 psi); Proof pressure: 1.5MPa (218 psi); Ambient and fluid temp: -5° to 60°C (23° to 140°F) (with no freezing)
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period. Maximum operating pressure: 1MPa (145 psi); Minimum operating pressure: 0.05MPa (7 psi); Proof pressure: 1.5MPa (218 psi); Ambient and fluid temp: -5° to 60°C (23° to 140°F) (with no freezing)
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period. Supply pressure: 0 to 1.0 MPa; Signal pressure: 0.25 to 0.8MPa; Time delay: 0.5 to 60s; Operating and fluid temp: -5° to 60°C (no freezing); Effective area (Cv): 0.14
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period. Transmitter-relay valve, metric threads; Fluid: air; Operating pressure: 0 to 1.0MPa; Effective area (Cv): 7mm² (0.38); Port size: Rc (PT) 1/8
(0.38) 3 Balanced Poppet 10.8 (0.6) 5 Rubber Spool 9.9 (0.55) 5 Metal Spool 18 (1) 5 18 (1) 5 6 (0.33) 3 Rubber Spool Metal Spool Balanced Poppet Dual pressure available only on external pilot. 3.5-2 Series VM Related Products No.of Ports Effective Area (mm2) (Cv) Function VR1210 Shuttle Valve 7 (0.38) 3 Dimensions (mm) VR1210: 17.2 X 38 X 29 VR1220: 21.2 X 50 X 38 VR1220 15 (0.81) 3 VR2110
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period.AND valve with one-touch fitting, Maximum operating pressure: 1MPa (145 psi), Minimum operating pressure: 0.05MPa (7 psi), Proof pressure: 1.5MPa (218 psi), Ambient and fluid temp: -5 to 60C (23 to 140F) (with no freezing), AND VALVE
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period.3 port check valve, Max. operating pressure: 1.0MPa, Ambient and fluid temp: -5 to 60C, Effective area (Cv): 0.38 to 0.81, SHUTTLE VALVE W/0 FITTING, VALVE, VR CHECK VALVE, F7, VR BODY PT 1/4, .15141 lb
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period.AND valve with one-touch fitting, Maximum operating pressure: 1MPa (145 psi), Minimum operating pressure: 0.05MPa (7 psi), Proof pressure: 1.5MPa (218 psi), Ambient and fluid temp: -5 to 60C (23 to 140F) (with no freezing), AND VALVE
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period.Shuttle valve with one-touch fitting, Maximum operating pressure: 1MPa (145 psi), Minimum operating pressure: 0.05MPa (7 psi), Proof pressure: 1.5MPa (218 psi), Ambient and fluid temp: -5 to 60 C (23 to 140 F) (with no freezing), SHUTTLE
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period.Shuttle valve with one-touch fitting, Maximum operating pressure: 1MPa (145 psi), Minimum operating pressure: 0.05MPa (7 psi), Proof pressure: 1.5MPa (218 psi), Ambient and fluid temp: -5 to 60C (23 to 140F) (with no freezing), SHUTTLE
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period.Transmitter-relay valve, metric threads, Fluid: air, Operating pressure: 0 to 1.0MPa, Effective area (Cv): 7mm (0.38), Port size: Rc (PT) 1/8, VALVE, RELAY, SGL PORT, VALVE, VR CHECK VALVE, DI, VR BODY PT 1/8, .71939 lb, FunctionSub-plateModelIndicatorSingle
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period.Transmitter-relay valve, metric threads, Fluid: air, Operating pressure: 0 to 1.0MPa, Effective area (Cv): 7mm? (0.38), Port size: Rc (PT) 1/8, VR BODY PT 1/8, VALVE, VR CHECK VALVE, D7, VR BODY PT 1/8, 0.6446 lb
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period.Transmitter-relay valve, metric threads, Fluid: air, Operating pressure: 0 to 1.0MPa, Effective area (Cv): 7mm (0.38), Port size: Rc (PT) 1/8, VALVE, RELAY, VALVE, VR CHECK VALVE, D7, VR BODY PT 1/8, .64460 lb