SMC Corporation of America
Elite Part Number Search
Search Results "VM121F-04-06"

Made to Order How to Order 2 1 F 06 200 AS S Lubricant: Vaseline -X12 Example) AS2002FS-04-X12 Made to Order Body size Grease-free (Seal: Fluorine-coated) + Restrictor (Without check valve) -X21 100 M5 standard 200 1/8 standard 205 1/4 standard 300 3/8 standard 400 1/2 standard Applicable tubing O.D.1 Example) AS2002FS-04-X21 * Not particle-free Metric size Inch size 23 3.22 04 4 06 6 08

D1 Port B min. port size Weight (g) D2 L1 L2 L3 L4 P Q1 Q2 M1 M2 4 4 6 KM16-06-06-3 12.8 4 6 KM16-04-04-3 16 17 17 KM16-04-06-3 6 16 16 17 19 18 3 4.5 18 4.5 12.8 68 20.9 16 11 14.5 50 10.5 65

ASD Model Meter-out type Rod and applicable tubing O.D. 4 6 8 10 Meter-in type AS1000P-04-04 AS2000P-04-04 AS2000P-06-06 AS2500P-06-06 AS3000P-08-08 AS3000P-10-10 AS1010P-04-04 AS2010P-04-04 AS2010P-06-06 AS2510P-06-06 AS3010P-08-08 AS3010P-10-10 AS AS-FE KE The lock nut provides identification.

27 19 53 42 34 22 1 4 3 8 KGH12-02 KGH12-03 34.5 28.5 19 12 23.5 22 58.3 46.1 30 1 2 3 8 1 2 KGH12-04 KGH16-03 KGH16-04 51 61 47 22 22 39.5 32 35.5 26.5 81 (81) 113 (96) 16 24 24 Connection thread Reference dimensions after R thread installation.

, 06, 07 01, 23, 03, 04, 06, 07 AS-F 06, 07, 08, 09, 10 500 08, 09, 10, 11 Flow rate L/min (ANR) Flow rate L/min (ANR) Flow rate L/min (ANR) 03, 04 TMH 400 200 06, 07 02 01, 23 ASD 300 50 03, 04 100 200 AS 01, 23 100 AS-FE 0 0 0 KE 5 0 10 5 0 10 5 0 10 Number of needle rotations Number of needle rotations Number of needle rotations AS-FG AS-FG Note) -U10/32 has the same specification as M5

Type Metric sizes Inch sizes Elbow Universal 2 3 3.2 01 23 1/8 5/32 3/16 1/4 5/16 3/8 1/2 04 06 08 10 12 03 05 07 09 11 13 4 6 8 10 12 Control type Meter-out Meter-in 0 1 Use 1/8 tubing.

-04 AS121F-M5-03 5/32" M5 x 0.8 M5 x 0.8 8 17.3 22.2 7 9.3 22.1 9.6 4 25 25.8 22.1 28.6 9.3 17.3 AS121F-U10/32-04 AS121F-U10/32-03 5/32" 10-32UNF 10-32UNF AS121F-M5-06 AS121F-M5-05 3/16" M5 x 0.8 M5 x 0.8 11.4 21.3 26.1 7 16.5 13.5 11.7 22.9 11.6 18.1 6 AS121F-U10/32-06 AS121F-U10/32-05 3/16" 10-32UNF 10-32UNF 8 11.7 28.6 25.8 22.2 25 9.6 AS221F-01-23 AS2 1F-M5-07 20.4 16 9.3 27.5 3.2 1/4

Clean One-touch fitting (for blow off) 04 06 08 10 12 4 6 8 10 12 01 02 03 04 00 04 06 08 10 12 R 1/8 R 1/4 R 3/8 R 1/2 Thread connection Tubing (rod) connection Model H L T Y U R Male connector, Straight union Union elbow, Male elbow Male branch tee, Union tee Male run tee Male branch, Union "Y" Plug-in reducer Plug Same dia. tubing 4 6 8 10 12 Different dia. tubing (plug-in reducer) Clean

Clean One-touch fitting (for blow off) 04 06 08 10 12 4 6 8 10 12 01 02 03 04 00 04 06 08 10 12 R 1/8 R 1/4 R 3/8 R 1/2 Thread connection Tubing (rod) connection Model H L T Y U R Male connector, Straight union Union elbow, Male elbow Male branch tee, Union tee Male run tee Male branch, Union "Y" Plug-in reducer Plug Same dia. tubing 4 6 8 10 12 Different dia. tubing (plug-in reducer) Clean

Clean One-touch fitting (for blowing) 04 06 08 10 12 4 6 8 10 12 01 02 03 04 00 04 06 08 10 12 Thread connection Tubing (rod) connection R 1/8 R 1/4 R 3/8 R 1/2 Model H L T Y U R Male connector, Straight union Union elbow, Male elbow Male branch tee, Union tee Male run tee Male branch, Union "Y" Plug-in reducer Plug Same dia. tubing 4 6 8 10 12 Different dia. tubing (plug-in reducer) Clean

Clean One-touch fitting (for blowing) 04 06 08 10 12 4 6 8 10 12 01 02 03 04 00 04 06 08 10 12 R 1/8 R 1/4 R 3/8 R 1/2 Thread connection Tubing (rod) connection Model H L T Y U R Male connector, Straight union Union elbow, Male elbow Male branch tee, Union tee Male run tee Male branch, Union "Y" Plug-in reducer Plug Same dia. tubing 4 6 8 10 12 Different dia. tubing (plug-in reducer) Clean

Terminal number Dimensions Applicable fittings size d 4 Model A L D 10-KQ2P-04 16 32 6 10-KQ2P-06 18 35 8 10-KQ2P-08 20.5 39 10 10-KQ2P-10 22 43 Connector Assembly for Flat Ribbon Cables 6 8 10 12 5 6 8.5 10 Cable length (L) 1.5 m 3 m 5 m AXT100-FC20-1 Assembly part no.

As the circulating fluid temperature is within the set range of "AS.06", "AS.06" alarm monitoring starts. Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts.

AS131FM-M5-23 AS131FM-M5-04 AS131FM-M5-06 AS231FM-01-23 AS231FM-01-04 AS231FM-01-06 AS231FM-01-08 AS231FM-02-04 AS231FM-02-06 AS231FM-02-08 AS231FM-02-10 3.2 19.8 8.4 17.5 28.7 12.7 M5 x 0.8 8 8 4 20.3 33.8 28.8 30.1 25.1 9.3 9.6 9.3 10.8 6 21.4 20.6 31.8 13.5 11.6 3.2 24.4 8.4 17 17.5 30.9 12.7 9.3 13.1 4 24.9 9.3 35.2 30.2 32.1 27.1 12 R 1/8 14.2 18 22.9 36.3 13.5 10.9 6 14 26.9 11.6 21

4 06 6 08 8 10 10 13 13 Symbol Thread Dia 2~8 10~16 40~50 20~32 A8 M8X1 Male Thread A10 M10X1 A14 M14X1 V A C U U M E N T R Y P A D T Y P E U Flat C Flat with Rib (Not 2,4,6,8) D Deep (10,16,25,40) B Bellows (Not 2,4) Symbol Port Size 2~8 10~16 40~50 20~32 04 4 Tube Onetouch Tube Fitting 06 6 Tube 08 8 Tube P A D M AT E R I A L N Nitrile Rubber (standard) S Silicon Rubber U Urethane

area (mm2) 01, 03, 04 05, 06 03, 04 Number of needle rotations Number of needle rotations Number of needle rotations AS321FG AS331FG AS421FG AS431FG Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 12, 13 10, 11 10, 11, 12 Flow rate (/min (ANR)) Flow rate (/min (ANR)) Effective area (mm2) Effective area (mm2) 08, 09 06, 07 Number of needle rotations Number of needle rotations 15-9-44 3 Speed

SY100-61-3-05 SY100-61-3-06 SY100-61-2-01 SY100-61-2-02 SY100-61-2-03 SY100-61-2-04 How to Use DIN Terminal Caution Connection 1. Loosen the holding screw and pull the connector out of the solenoid valve terminal block. 2.

(Check leakag) 100 lloninntal lype Uacuum tntny: Without BufleU Wilh Ban[eil ]itting Specif ications l',.1.t':.,.l,',,,l,. : : : t : . : : . : : . ,t I , i I .. .1. q2-6 8:t) 04 . 06 Nylon tube, 04 . 06 Urethane tube olQ-s16 04 . 06 Nylon tube, a4. 66 Urethane tube szj-sgz 04. oO Nylon tube, @4. oO Urethane tube s40-o5O o6 Nylon tube, oG Urethane tube Vacuum entry Connection o2-o I M 5 x

(Check leakag) 100 lloninntal lype Uacuum tntny: Without BufleU Wilh Ban[eil ]itting Specif ications l',.1.t':.,.l,',,,l,. : : : t : . : : . : : . ,t I , i I .. .1. q2-6 8:t) 04 . 06 Nylon tube, 04 . 06 Urethane tube olQ-s16 04 . 06 Nylon tube, a4. 66 Urethane tube szj-sgz 04. oO Nylon tube, @4. oO Urethane tube s40-o5O o6 Nylon tube, oG Urethane tube Vacuum entry Connection o2-o I M 5 x

40 BM1-05 50 BM1-06 63 BA-01 20 BA-02 25 BA-32 32 BA-04 40 BA-05 50 BA-06 63 BA-08 80 BA-10 100 Courtesy of Steven Engineering, Inc. !