This product uses a built in pump to circulate liquid (water or 20% EG) at a constant temperature, controlled by Thermo-Electric (Peltier) Modules.
Use formula as shown below: Load(N) Bore size(m) D2 Operating Pressure(Pa) 4 <Eg.> Bore size: 40(0.04m) Load: 200N (Allowable kinetic Energy) Operating Pressure: 0.5MPa(5105Pa) 200 0.040.043.145105 100 = 31.8 = 30 4 Round-off P6No. of Brake operation P7Origin Detection Time Set the Origin Detection time (t1). (10ms as 1 unit, maximum will be 9.99s) After inputting the homing (returning
Use formula as shown below : Load(kg) Bore size(cm)xr2x xOperating Pressure(Mpa) 4 <Eg.> Bore size:40cm Load : 20kg(Allowable kinetic Energy) Operating Pressure : 0.5MPa 20kg 4x4x x0.5 x1000=31.8=30% 4 P6 No. of Brake operation P7 Origin Detection Time Set the Origin Detection time(t1) (10ms as 1 unit, maximum will be 9.99s) After inputting the homing (returning to origins) signal.
Eg) -12.3 1, 2, , 3, Entry of alpha character: To enter a character which is printed on the key by pressing the key for multiple times until it is displayed on the screen or Shifts to the next letter by pressing the left or right key. It is used when entering parameter or step data for which characters can be entered and for names of the parameter files.
JXC-OMY0004-A 12.2 Pushing Operation Eg.) Move the actuator from the origin to a point 100 mm away at 100 mm/s. (Step Data No.1 is used for this operation). From the 100 mm point, the actuator must start a pushing operation of 10 mm/s speed and 50% or less force. (the pushing distance is up to 5 mm).
The 10 mm move is completed. 74 - 13.2 Pushing Operation Eg.) Move the actuator from the origin to a point 100 mm away at 100 mm/s. (Step Data No.1 is used for this operation). From the 100 mm point, the actuator must start a pushing operation of 10 mm/s speed and 50% or less force. (the pushing distance is up to 5 mm).
Signal Style and Part No. 2500 2500 This product uses a built in pump to circulate liquid (water or 20% EG) at a constant temperature, controlled by Thermo-Electric (Peltier) Modules.
Normal concentration: 55 to 60% High concentration EG in the circulating fluid may cause circulating pump overload, which triggers Pump Breaker Trip FLT. Potential cooling error may occur if the circulating fluid varies in concentration. When the circulating fluid is a fluorinated fluid Make sure of no oil, moisture, and other foreign materials contaminate the circulating fluid.
This product uses a built in pump to circulate liquid (water or 20% EG) at a constant temperature, controlled by Thermo-Electric (Peltier) Modules. This circulating fluid cools parts of the customers machine that generates heat. 3.2 General Specifications This symbol warns you of potential electrical shock. This symbol warns you of potential burns. Item Spec. Model No.
(eg. protection cover) M2 We We W4 m FE L3 L2 W1 L1 Note ) -X ME 1 3 ME = FEL1 = 0.05am L1 (Nm) YES NO 20NO Note) Average load coefficient (This coefficient is meant to average the maximum load moment at the time of impact with stopper in the light of calculating the service life.) Do not use since it will cause breakage of sensor or air leakage.
It may be desirable to protect cylinder (eg. protection cover). M1 M2 YES W4 NO W1 NO Do not use since it will cause breakage of sensor or air leakage. Yaw moment M3 = W4 x L2 YES L2 Is there any influence of noise? (Refer to Caution on Handling on pages 706 and 707.) Install a noise filter. NO M3 There is no particular problem in using the system.
Since it is extremely difficult to measure the ozone concentration in pressurized air while it is in lines, samplings of pressurized air were taken from certain points in the pneumatic circuit (see to below) and the ozone concentration was measured immediately, using an ultraviolet absorbent densitometer (EG-2001F made by EBARA JITSUGYO CO., LTD).
SERIES NAN SILENCER NAN200-N02 14 35 (1.9) NAN300-N03 38 60 (3.3) Dimensions (mm) Model NAN400-N04 12 90 (5.0) A B D NAN500-N06 34 160 (8.8 NAN200-N02 63 22 19 NAN600-N10 1 270 (15) NAN300-N03 84 25 22 NAN700-N12 114 440 (24) NAN400-N04 92 30 27 NAN800-N14 112 590 (33) NAN500-N06 107 46 36 NAN900-N20 2 960 (53) NAN600-N10 132 50 41 Note: When ordering PT Ports, remove (N) from Model Number Eg
VFS2000, body ported and base mounted valves, Thread type: Rc(PT), Port sizes: 1/8, 1/4, Maximum operating pressure: 9.9kgf/cm2, Ambient and fluid temperature: -10 to 60 C, Manual override: non locking push style, VALVE DBL SOLENOID BODY PT, VALVE, VFS2000 SOL VALVE 4/5 PORT, EG, VFS2000 BODY PT 1/4NPT (F), 1.0336 lb
Please contact us for the latest version.sales@ocaire.com, VALVE, AIR PILOT, BODY PT, VALVE, SY7000 SOL/VALVE, RUBBER SEAL, EG, SY7000 BODY PT 1/4 NPT, .41800 lb
Please contact us for the latest version.sales@ocaire.com, VALVE, DBL SOL, BODY PT (DC), VALVE, SY7000 SOL/VALVE, RUBBER SEAL, EG, SY7000 BODY PT 1/4 NPT, 0.44092 lb
VFS3000, body ported and base mounted valves, Thread type: Rc(PT), Port sizes: 1/4, 3/8, Maximum operating pressure: 9.9kgf/cm2, Ambient and fluid temperature: -10 to 60 C, Manual override: non locking push style, VALVE DBL SOLENOID BODY PT, VALVE, VFS3000 SOL VALVE 4/5 PORT, EG, VFS3000 BODY PT 1/4NPT (F), 1.188 lb
Please contact us for the latest version.sales@ocaire.com, VALVE DBL SOL BODY PORTED, VALVE, VFS3000 SOL VALVE 4/5 PORT, EG, VFS3000 BODY PT 1/4NPT (F), 1.232 lb
Please contact us for the latest version.sales@ocaire.com, VALVE, DBL SOL, BODY PT, DIN, VALVE, SY7000 SOL/VALVE, RUBBER SEAL, EG, SY7000 BODY PT 1/4 NPT, 0.37478 lb
Please contact us for the latest version.sales@ocaire.com, VALVE, DBL SOL, BODY PT, DIN, VALVE, SY7000 SOL/VALVE, RUBBER SEAL, EG, SY7000 BODY PT 1/4 NPT, 0.39683 lb