SMC Corporation of America
Elite Part Number Search
Search Results "SV4000-50-2A-03N"

The use of 34 pin connectors allows up to 16 stations with double solenoids.SV4000 series valve, Single, double solenoid and 3 position available, Service life: 50 million cycles or more, Supply pressure: 0.5MPa, Unrestricted mounting orientation SV4000 SOLENOID VALVE. SV4000 NO SIZE RATING. VALVE. SV4000 NO SIZE RATING. 1.76369 lb. 2I.

The use of 34 pin connectors allows up to 16 stations with double solenoids.SV4000 series valve, Single, double solenoid and 3 position available, Service life: 50 million cycles or more, Supply pressure: 0.5MPa, Unrestricted mounting orientation SV4000 SOLENOID VALVE. SV4000 NO SIZE RATING. VALVE. SV4000 NO SIZE RATING. 1.32277 lb. 2E.

The use of 34 pin connectors allows up to 16 stations with double solenoids.SV4000 series valve, Single, double solenoid and 3 position available, Service life: 50 million cycles or more, Supply pressure: 0.5MPa, Unrestricted mounting orientation SV4000 SOLENOID VALVE. SV4000 NO SIZE RATING. VALVE. SV4000 NO SIZE RATING. 1.32277 lb. 2E.

The use of 34 pin connectors allows up to 16 stations with double solenoids.SV4000 series valve, Single, double solenoid and 3 position available, Service life: 50 million cycles or more, Supply pressure: 0.5MPa, Unrestricted mounting orientation SV4000 SOLENOID VALVE. SV4000 NO SIZE RATING. VALVE. SV4000 NO SIZE RATING. 1.22797 lb. 2I.

/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz External pilot Nil VT N.C.

-64-1A 1NA SX5000-64-1A 1NA t-1 SX3000-64-26 2A 2NA SX5000-64-26 2A 2NA t-2 Note) 24 VDC -2A: +COM. -2NA: COM. 2A 2NA SX3000-64-20 2A 2NA SX5000-64-20 t-3 2A 2NA SX3000-64-10 2A 2NA SX5000-64-10 t-4 t-5 SX5000-64-3A SX3000-64-3A In common between +COM and COM.

(V) 24, 6, 12, 48 15 to +10% of rated voltage 1.8 (With indicator light 2.1) [24 VDC: 75 (With indicator light 87.5)] Allowable voltage fluctuation (%) Note) Power consumption (W) [Current mA] DC 4.5/50 Hz, 4.2/60 Hz 100 VAC: 45/50 Hz, 42/60 Hz 200 VAC: 22.5/50 Hz, 21/60 Hz Note) Inrush Apparent power (VA) [Current mA] AC 3.5/50 Hz, 3/60 Hz 100 VAC: 35/50 Hz, 30/60 Hz 200 VAC: 17.5/50 Hz

1 VVFS5000-2A-1 VVFS5000-2A-2 End plate (U side) assembly !

.1 1-1 EDB 2A.2 1-2 EDB 2A.3 1-3 EDB 2A.4 1-4 EDB 2A 1 2A.5 1-5 EDB 2A.6 1-6 EDB 2A.7 1-7 EDB 2A.8 1-8 EDB 2B 2B.1 1 EDB 2B.2 2 EDB 30.1 DB (1) (1) (1) 30.2 DB 30 (1) (1) (1) (1) 30.3 DB (1) (1) (1) 31 31.1 / SD 8 3 8.

Fittings & Tubing Air Cylinders Rotary Actuators Note 1) Actuation Voltage Electrical entry Light/surge voltage suppressor Sonic conductance C [dm3/(sbar)] 2 position 3 position DC AC 100 V 50/60 Hz 110 V 50/60 Hz 200 V 50/60 Hz 220 V 50/60 Hz M plug connector L plug connector 24 V Note 4) Series M8 connector Pressure center 12 V DIN terminal { } 4/25/3 (A/BEA/EB) Closed center Exhaust center

Refer to the cylinder catalog for details. 10 Optimum Actuation Size Chart of Air Cylinder For JSY3000, A, B port: 8 Horizontal Vertical (Upward) Average speed [mm/s] 0 100 200 300 400 500 600 700 800 32 CM2 series Pressure: 0.5 MPa Load ratio: 50% Stroke: 300 mm 40 50 63 CA2 series Pressure: 0.5 MPa Load ratio: 50% Stroke: 500 mm 80 100 125 CS1 series Pressure: 0.5 MPa Load ratio: 50% Stroke

connector LO 110 VAC 50/60Hz 5000mm 50 3 With lead wire M [115 VAC 50/60Hz] M plug connector Without lead wire MN 220 VAC 50/60Hz 4 Without connector MO [230 VAC 50/60Hz] Without connector cable WO M8 connector For type "W", DC voltage is only available.

Seal Coil voltage 1 100 VAC (50/60 Hz) 2 200 VAC (50/60 Hz) 3 110 VAC (50/60 Hz) 4 220 VAC (50/60 Hz) 5 24 VDC 6 12 VDC Series Enter in order starting from the first station on the D side.

40 85 20 20KJlD 25 17 45 70 Single knuckle joint Accessory Data GKM20 10 50 100 Double knuckle joint JA-Floating joint 20 10 50 70 Rubber cushion Air cushion ( ): In the case of air cushion Calculation: (Example) C85N10-50, C85F10 Basic weight 49 (10)g Additional weight 3.2/10 mm of stroke Cylinder stroke 50 mm Mounting bracket 12g 49 + 3.2 x 50/10 = 65g 65 +12 = 77g Non-rotating rod: Double

N.O. 13.5 SYA 12 NC 26.2 65.2 58.2 3R 58.2 27 50 50.1 65.2 SYJA 1P 26.2 NO 12 VZA 1/4 1(P), 3(R) port 1/8 (Pitch) P = 27.5 12(PA) port 28 M5 x 0.8 (Breathing hole) VFA 7.5 L2 L1 VFRA (Station n) (Station 1) 1/8 12(PA) port VPA4 12 SYJA 73.5 54 VZA 37.5 11 2A 2A VTA 1/4 2(A) port (Pitch) P = 27.5 28 VGA 2 stations 83.5 68.5 111 96 138.5 123.5 166 151 193.5 178.5 221 206 248.5 233.5 276 261

SY100-30-3AS Z Without lead wire: (with connector and 2 of sockets only) SY100-30-A Rated voltage R 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] Lead wire length U Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm For AC voltage valves there is no S option.

block assembly (Standard): SX3000-51-2A The following columns shall be filled in by SMC.

/60Hz) 2* 200VAC (50/60Hz) 3* 110VAC (50/60Hz) 4* 220VAC (50/60Hz) 5 24VDC 6 12VDC 9* Others Courtesy of Steven Engineering, Inc. !

60 50 100V AC Hz 110V AC Hz 200V AC Hz 220V AC Hz Closed center Exhaust center Pressure center 60 50 60 M5 X 0.8: 1.8(0.1) 50 60 (1) AC Push-turnlocking slotted style With light and surge voltage suppressor SYJ5000 Rc(PT)1/8: 4.5(0.25) SYJ7000 Rc(PT)1/8, 1/4: 12.6(0.7) Note 1) All AC voltage models have built-in surge voltage suppressor. 1.2-2 Series SYJ3000/5000/7000 Manifold Variations